background image

7

DIVE 18 RGB

DIVE R 18 RGB 

LEDs OUT 7

DIVE R 18 RGB

6-pin Female (RJ12)

1

6

03.LA.053 (RJ12 OUTPUT)

LED UNITS WIRING CONNECTION

DIVE 18

IMPORTANT

:

Each DIVE 18 UNIT need 2 x Z60 
outputs in order to be properly 
controlled.

The Total number of DIVE 18 
connectable to Z60 is 10 pcs
The Total number of DIVE 18 
connectable to Z30 is 5 pcs

Never plug in a new unit when the 
power supply is turned on. 

Содержание DIVE 18 RGB

Страница 1: ...GB User s Manual Rel 1 3 D T S Illuminazione srl ITALY http www dts lighting it DIVE 18 DIVE R 18 RGB DIVE 18 RGB Made in Italy...

Страница 2: ...ucts or circuits described herein Les informations contenues dans le pr sent manuel ont t r dig es et contr l es avec le plus grand soin Nous d clinons toutefois toute responsabilit en cas d ventuelle...

Страница 3: ...fferent whites are also selectable by the user Three interchangeable lens fittings are available Spot Medium Flood and Wide Flood These three lenses offer different aperture angles for the light beam...

Страница 4: ...0 max 10 units or Z30 max 5 units Connection Provided with 5 mt of cable and with a RJ12 connector Weight 6 3 Kg ACCESSORIES Lenses sets Spot Cod 02LK046 Medium flood Cod 02LK047 Wide flood Cod 02LK04...

Страница 5: ...erials 10 cm Safety The external surface of the unit may exeed 50 C never handle the unit until at least 5 minutes have elapsed since the unit was turned off The ambient temperature should not exeed 4...

Страница 6: ...is not necessary DIVE 18 LED PROJECTOR cabling connection can be done with a standard UTP B2 category 5E cable The maximum distance between power supply and the DIVE 18 unit should not exceed 100 met...

Страница 7: ...T LED UNITS WIRING CONNECTION DIVE 18 IMPORTANT Each DIVE 18 UNIT need 2 x Z60 outputs in order to be properly controlled The Total number of DIVE 18 connectable to Z60 is 10 pcs The Total number of D...

Страница 8: ...2 T BOX 2 DIVE R 18 RGB DIVE R 18 RGB IMPORTANT The maximum number of DIVE 18 UNIT connectable to the Z1 Power supply is 2 pcs Never plug the cable coming from the Power supply into OUT 1 or OUT 2 of...

Страница 9: ...JECTOR connectable to the Z4 Power supply is 2 pcs each LED output 8 pcs totally Never plug in a DIVE 18 unit when the power supply is turned on 9 INPUT OUT 1 OUT 2 T BOX INPUT OUT 1 OUT 2 T BOX INPUT...

Страница 10: ...NOTES 10 DIVE 18...

Страница 11: ...NOTES 11 DIVE 18...

Страница 12: ...mpletely without prior written consent from D T S D T S reserves the right to make any aesthetic functional or design modifications to any of its products without prior notice D T S assumes no respons...