18
2.2.4. Setting Up Multiplication and Clock Division
The operation clock for the target microcomputer is calculated and set using the specified
values of C6 and C8 at MCU Clock Frequency [FUNC FD] and [Parameter Table2] display.
Calculation Method:
Operation clock = MCU Clock Frequency ×Multiplication/Clock Division
*Set the value within the settable range of the target microcomputer.
For the setting range, see the hardware manual for the microcomputer.
How to set:
The following window is displayed when you select Parameter Table2 tab. Enter “AF200” and
then click the OK button. (The password which you entered is masked with “*”.)
(1) Multiplication
Enter the multiplication value at C6 in hexadecimal.