21.  

         

  

22. This equipment shall not be used for life support system. 
23. A periodical checking of power adapter is necessity if they are any abnormal condition happened shall be 

contact with manufacturer, refer to item 22. 

24. The equipment is placed front side in normal use that shall not be undertaken in transport position. 
25. If you notice any abnormalities such as odor, noise, or smoke, stop using this device. Otherwise a fire or 

burn may result.  Remove the batteries carefully to avoid burning yourself, and contact your dealer or 
consult DT RESEARCH INC. 

26. External equipment intended for connection to signal inputs, signal outputs or other connectors shall comply 

with the relevant product standard e.g. IEC 60950-1 or IEC 62368-1 for IT-equipment and the IEC 60601-
series for Medical Electrical Equipment. In addition, all such combinations 

– Medical Electrical Systems – 

shall comply with the safety requirements stated in the general standard IEC 60601-1, edition 3, clause 16. 
Any equipment not complying with the leakage current requirements in IEC 60601-1 shall be kept outside 
the patient environment i.e. at least 1.5 m from the patient support or shall be supplied via a separation 
transformer to reduce the leakage currents. 

  

Any person who connects external equipment to signal inputs, signal outputs or other connectors has 
formed a Medical Electrical System and is therefore responsible for the system to comply with the 
requirements. If in doubt, contact qualified medical technician or your local representative. 

27. 
 

FCC Regulations 

 

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device 

may not cause harmful interference, and (2) this device must accept any interference received, including interference that 
may cause undesired operation. 
 

This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the 

FCC  Rules.  These  limits  are  designed  to  provide  reasonable  protection  against  harmful  interference  in  a  residential 

installation.  This  equipment  generates,  uses  and  can  radiated  radio  frequency  energy  and,  if  not  installed  and  used  in 

accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee 

that  interference  will  not  occur  in  a  particular  installation  If  this  equipment  does  cause  harmful  interference  to  radio  or 

television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct 

the interference by one or more of the following measures: 

 

-Reorient or relocate the receiving antenna. 

-Increase the separation between the equipment and receiver. 

-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 

-Consult the dealer or an experienced radio/TV technician for help. 

 
Changes or modifications not expressly approved by the party responsible for compliance could void the user‘s authority to 
operate the equipment. 

 

Packing List 

Before installing your Digital Terminal, ensure that the following materials have been received: 

 

Medical Cart Computer, DT313 

 

User's manual 

 

Power Adapter , EDAC POWER ELECTRONICS CO LTD, Model  EM11011M 
(Rated Input 100-240 Vac, 2.0-1.0 A, 50-60 Hz. Output: 19 Vdc,6.31A) 

 

Base stand (optional) 

MEDICAL 

 GENERAL MEDICAL EQUIPMENT 

AS TO ELECTRICAL SHOCK, FIRE AND MECHANICAL 
HAZARDS ONLY IN ACCORDANCE WITH 

ANSI/AAMI ES 

60601-1 (2005) + AMD (2012) &"CAN/CSA-C22.2 No. 
6060-1 (2008) + (2014) 

 

Содержание DT313 series

Страница 1: ...Version 1 0 Medical Cart Computer DT313 SERIES User s Manual...

Страница 2: ...e DT313 series is ready for use out of the box in its default configuration when powered by the power source provided The following discussion offers guidance on the hardware elements and features of...

Страница 3: ...Version 1 0 Customize Mobility Center Security Keyboard IEC 60417 5032 AC Atmospheric pressure limitation Humidity limitation Temperature limitation...

Страница 4: ...Transportation 20 C 60 C Operation 0 C 40 C Storage 20 C 60 C Humidity Transportation 0 90 Operation 0 90 Storage 0 90 Atmospheric Pressure Transportation 70 0 kPa to 106 0 kPa Operation 70 0 kPa to 1...

Страница 5: ...CC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may c...

Страница 6: ...intended use for general operator Not intended for patient used Attention Les Panel PC sont utilisation pr vue pour l op rateur Ne pas utiliser patient Grounding reliability can only be achieved when...

Страница 7: ...Version 1 0 Function Instructions 1 Input Output Ports and Button Functions...

Страница 8: ...NOT apply excessive pressure to the display screen We recommend using the Digital Pen optional to keep the screen clean Avoid prolonged exposure of the display panel to any strong heat source Whereve...

Страница 9: ...ovided in the software operating system Wireless Networking Wireless LAN The DT313SC MD DT313T MD is often delivered with an embedded user inaccessible 802 11ac WLAN adapter equipped with a hidden cus...

Страница 10: ...ntable cradle options These securable and mountable cradles provide an interface to VESA mounts and arms and to ports that may include USB Ethernet and pass through power For More Support Users can do...

Страница 11: ...igh temperature it will speed up chemical metabolism and shorten the battery service life Please don t store the battery in a temperature over 60 C It may cause the battery explode 4 Caution 1 The bat...

Страница 12: ...acement des piles au lithium ou les piles combustible par du personnel mal form Battery change 1 Remove the battery Push the switch up to unlock the latch then slide the latch left to remove the batte...

Страница 13: ...SB ports Instructions Connect the AC DC adapter cable to the DC input jack and then insert the Tablet system properly for charging Package Contents 1 Desktop Cradle 2 Basic Operation Guide Precautions...

Страница 14: ...20 C 60 C Humidity 0 90 non condensing The AC DC Adapter is not included in the standard package Specificati uons subject to change without notice Tablet Mont Cradle BASIC OPERATION GUIDE INTRODUCTION...

Страница 15: ...o the cradle first with the connector parts correctly lined up 3 When the bottom of the Tablet is in place push the Tablet against the back and into the Cradle 4 Push down on the Top Clasp so the top...

Страница 16: ...should be at Guidance and manufacture s declaration electromagnetic emission The device is intended for use in the electromagnetic environment specified below The customer of the user of the device s...

Страница 17: ...ued operation during power mains interruptions it is recommended that the device be powered from an uninterruptible power supply or a battery Power frequency 50Hz 60Hz magnetic field IEC 61000 4 8 30...

Страница 18: ...rformance is observed additional measures may be necessary such as re orienting or relocating the device b Over the frequency range 150 kHz to 80 MHz field strengths should be less than 3 V m Recommen...

Страница 19: ...hould be installed and operated with minimum distance 0cm between the radiator and your body This transmitter must not be co located or operating in conjunction with any other antenna or transmitter T...

Страница 20: ...AR la plus lev e signal e en vertu de cette norme lors de la certification de produit utiliser lorsqu il est correctement port sur le corps Le SAR est r alis sur une plaque mobile dt313 quip e d un mo...

Отзывы: