background image

 

3. 

Operation Instructions 

3.1 

As the paging hub of a P.A. system, it can be connected to 10 systems through a router for central 

control. The paging hub can be connected to 10 sets of PC1010P, controlling 10 PC10 systems  of 

up to 100 zones. 

3.2 

Each PC1010R connecting to the PC1010R IN interface of the paging hub can control 10 zones of 

the PC1010P system. 

3.3 

Total  10  data  output  interfaces,  1  data  input  interface,  10  Type  D  audio  output  interfaces  and  10 

Type D audio input interfaces are equipped on the paging hub.   

1) 

 

The  10  data  output  interfaces  of  the  paging  hub  are  respectively  connected  to  the  DATA  IN 

interfaces of PC1010P of 10 systems.   

2) 

 

The 10 Type D output interfaces are respectively connected to Type D interfaces of PC1010P 

of 10 systems.   

3) 

 

The 10 Type D input interfaces are respectively connected to PC1010R of each system.   

3.4 

Selection of Power Supply 

For suitable mains supply of different countries, three voltage operation modes are provided for all 

peripheral devices of the system.   

1.    For 220V-230V AC power supply; 

2.    For 110V AC power supply; 

3.    For 24V DC power supply: In this mode, the system can operate by using spare power supply, 

i.e.  when  220V  and  110V  AC  power  is  not  available,  the  system  operates  directly  by  using 

24V DC power by 24V battery box that is connected to PC1022E (emergency power supply of 

the P.A. system) and offers power to devices requiring power.   

The power supply mode is set by the voltage selector on the rear panel (as shown below). 

 

 

 

 

 

 

AC110V power selected                                        AC220V power selected 

1) 

 

Turn  the  selector  to  the  right  position  when  115  is  shown  to  indicate  that  the  110V  mode  is 

selected. 

2) 

 

Turn  the  selector  to  the  right  position  when  230  is  shown  to  indicate  that  the  220V-230V 

modes are selected. 

3) 

 

24V  DC  power  supply  can  be  used  directly  when  the  two  power  supplies  above  are  not 

available.   

Отзывы: