6.0
MAINTENANCE
CAUTION: DO NOT DISPOSE OF BATTERIES IN FIRE
CAUTION: DO NOT ATTEMPT TO OPEN THE BATTERIES
CAUTION: THE FOLLOWING PRECAUTIONS SHOULD BE TAKEN WHEN
REPLACING ANY BATTERIES
•
REMOVE WATCHES, RINGS, ETC…
•
USE TOOLS WITH INSULATED HANDLES.
CAUTION: USE RUBBER PROTECTIVE GLOVES WHEN HANDLING
DAMAGED BATTERIES.
WARNING
: HIGH VOLTAGE IS PRESENT ON BATTERIES.
1. Semi-annual
i. Cabinet/Electronics
1. Inspect all fans and insure proper operation.
ii. Batteries/Battery
Cabinet
1. Inspect the battery cases for leakage.
2. Perform a battery load test of each individual battery.
a. Turn off the Battery Breaker
b. Using a Battery load tester connected to only one
battery test the battery and record the battery voltage
after a 5 to 10 second load test. The picture to the left
is an example of the type load tester that can be
used.
c. Repeat step “b.” using the same timed load test, and
record the data.
d. After the testing all the batteries, compare the test
data. All recorded voltages should be approximately
the same value. Any batteries that have a reading
considerably different then the others needs to be
investigated, or considered to be bad and replaced.