ISOSTEM USER MANUAL
46 ISOSTEM® Live - Integration
The schematic diagram shown below presents an example of the matrix´s
conditional processing by merely handling the alarm relay output of
ISO-
STEM
®
#1:
If ALARM#1 (independently of the alarm state of
ISOSTEM
®
#2) repre-
sents a fully functional state, the audio matrix routes the AES data only to
ISOSTEM
®
#1.
If ALARM#1 represents a failure, switch-over to the backup
ISOSTEM
®
#2
is effected.
ISOSTEM
®
#1 may now be exchanged without interrupting the
audio line. It must be noted that, after exchanging the formerly failed
ISO-
STEM
®
#1, the audio matrix will switch back to
ISOSTEM
®
#1 because it
will signal ALARM#1 = OK.
In this example, in the case that both devices fail,
ISOSTEM
®
#2 receives
the audio data. But as it has a failure, it just bypasses the AES-data from
input to output.
Input-
Matrix
CPI-1
Output-
Matrix
CPO-1
ALARM#2
ISOSTEM#2
ALARM#1
ISOSTEM#1
CPI-2
CPO-2
4 x AES-IN
4 x AES-OUT
IF
(ALARM#1 = OK)
THEN
Switch-on In-/Out-
Crosspoint to ISOSTEM#1.
Switch-off In-/Out-
Crosspoint for ISOSTEM#2.
Input-
Matrix
CPI-1
Output-
Matrix
CPO-1
ALARM#2
ISOSTEM#2
ALARM#1
ISOSTEM#1
CPI-2
CPO-2
4 x AES-IN
4 x AES-OUT
IF
(ALARM#1 = ERROR)
THEN
Switch-off In-/Out-
Crosspoint to ISOSTEM#1.
Switch-on In-/Out-
Crosspoint for ISOSTEM#2.
Example of conditional processing for proper audio routing
P
RESET
R
ECALL
S
YNCHRONIZATION
In linked redundant mode, both GPI ports have to be interconnected in par-
allel as shown in the schematic diagram above. Thus preset recall actions
are processed by both devices synchronously. This ensures that the back-
up device always runs in the same mode as the current processing device.
P
RESET
M
ANAGEMENT
S
YNCHRONIZATION
ISOSTEM
®
Live´s PC-based graphic user interface (GUI) allows for man-
agement of the six preset memories. Presets can be read from the PC and
stored in the device´s preset memory.
In redundant setups, the user has to synchronize the preset content and
memory assignment manually. Future GUI and firmware revisions will offer
automatic synchronization of parameters and preset memories via the link
port.