INSTALLING THE CAMERA

 

SD series cameras are carefully packed to prevent 
damage in transit. First of all, it is necessary to check 
the material received. The speed dome camera you 
have purchased is protected by packing elements which 
must be carefully removed before using it. 
 

Realization of the wiring 
with command from RS485 

A cable with the following connections comes out of an 
SD Series Speed Dome camera: 
 

 

112VDC power supply with 5.5 mm plug. 

 

Video outputBNC female 

 

2 CablesBUS RS485 YELLOW (A +) / ORANGE (B-) 

 

 
To structure a Speed Dome camera system, 3 types of 
cabling must be prepared: 

 

Diet. It is possible to power the camera locally with 

a 220VAC / 12VDC adapter of at least 3A (not supplied) 
or arrange a 12VDC network with cables of adequate 
section in order to avoid excessive voltage drops. 

 

Video connection.It is realized as for any 

traditional analog CCTV camera. The video signal 
produced by this camera can be set to composite video 
CVBS or AHD / CVI / TVI depending on the DVR to be 
connected to, but there are no differences in the type 
of cabling of these two technologies. RG59 coaxial 
cable is generally used for distances up to 2-300 
meters. It is also possible to carry the video signal on 
twisted pairs using special converters (RE-BNCRJ1) up 
to about 200 m. The twisted pair converters are also 
available in the active version to reach distances over 
200 m. 

 

Telemetry.This is the serial connection that 

conducts motion commands to the camera. The SD 
series cameras use an RS485 serial line (BUS RS485) 
which must be created with a pair of twisted cables. It 
is essential that the 2 cables are wound together and 
not parallel. Theoretically, the RS485 serial line can 
extend up to 1200 meters in length and the devices are 

connected in cascade along it. The section of the cables 
strictly depends on the length of the connection: for 
medium distances a section of 0.5 mm is sufficient, 
while if it is necessary to reach considerable distances 
(max. 1200 m.), Higher sections of 1 mm or even 2.5 
mm must be used. When carrying out the wiring, it is 
advisable, but not essential, to use a shielded cable. 
The CAT5 network cable, 
The cameras and consoles must be connected in 
cascade, i.e. entering and exiting the 2 terminals 
RS485A and RS485B. It is important not to invert the 
two cables (AB) when connecting the equipment. 
The order in which the devices are connected to the 
BUS does not matter. Each device will be identified by 
its own unique address, which can be set via 
microswitches, which will allow the instructions to be 
correctly addressed. Up to 256 cameras can be 
connected to the same BUS. The consoles do not 
require any addressing, while for the cameras it is 
necessary to set a different address for each camera, 
as described below. 
 

Realization of wiring with 
UTC command on video 
cable 

If you have a UTC controlled DVR, such as our RK 
Series DVRs, you can send commands to the camera 
over the video cable without having to wire the twisted 
pair. To use this command, UTC must be selected as 
the protocol in the NVR instead of Pelco D. The RS485 
connectors are left unused. 
Note  that  if  the  camera  receives  commands  via  UTC, 
some functions may not be usable with respect to the 
RS485 connection. 
 

Command bodies 

The movements of these cameras are controlled via the 
common PELCO P / D protocol, now a consolidated 
industry standard. It is possible to send the commands 
with the special consoles for speed dome cameras or 
through the DVRs equipped with RS485 port. 
UTC-controlled DVRs can control these motorized 
cameras with just the video cable 
 

Address, protocol and Baud 
Rate 

After connecting the camera, it is necessary to set the 
communication parameters so that it is able to 
communicate with the control units. 
All the elements of the RS485 BUS, both cameras and 
control units, must use the same protocol (PELCO D 

Содержание SD-5 Series

Страница 1: ...USER MANUAL SPEED DOME CAMERAS SD xxx 5 Page 1 WWW DSE EU SD xxx 5 SERIES Cameras motorized AHD analog 8V ERWP EX IH J V SQ X EP M ER X S RKP M WL SRP M RIHSGX V ERWP EX SV GSQ...

Страница 2: ...red to as PTZ which stands for PAN TILT ZOOM PAN is the horizontal movement TILT the vertical movement and ZOOM the control of the focal length of the lens Control of PTZ cameras The speed dome camera...

Страница 3: ...ables strictly depends on the length of the connection for medium distances a section of 0 5 mm is sufficient while if it is necessary to reach considerable distances max 1200 m Higher sections of 1 m...

Страница 4: ...is BAUD RATE 2400 BPS ADDRESS 1 The communication data set in the camera is superimposed on the image Set the final protocol data of the camera Once the control center has been set to the PelcoD 2400...

Страница 5: ...d as desired 6 Go to SAVE and save with the arrow on the right 7 Exit with the left arrow several times Once the address or the protocol speed has been changed the camera will no longer respond to com...

Страница 6: ...utively CVBS Call preset 140 twice AHD Call preset 137 twice TVI Call preset 138 twice CVI Call preset 139 twice ATTENTION These control presets only work with RS485 protocol they do not work with UTC...

Страница 7: ...USER MANUAL SPEED DOME CAMERAS SD xxx 5 Page 7 WWW DSE EU Other types of brackets are optionally available...

Страница 8: ...ole keyboard buttons If you are using a so called 3D console it is also possible to control the zoom by rotating the joystick head If necessary you can change the focus by pressing the FOCUS buttons o...

Страница 9: ...he cameras can perform automatic movements such as panoramic scans or preposition sequences These movements are set in the programming menu which is described below These movements are started with th...

Страница 10: ...t between 2 limit switch limits with the same TILT level is defined as AB SCAN 94 CALL Close OSD menu Closes the overlay menu for camera configuration 95 CALL Opens OSD menu Activate the overlay menu...

Страница 11: ...ed above however there are further controls in the OSD menu Access to the general OSD menu To access the OSD configuration menu simply call up from the console or DVR the System PRESET 95 Typically yo...

Страница 12: ...arts the selected tour DELETE Clears all presets of the selected tour AB SCAN It means the continuous RIGHT LEFT movement between 2 limit switch positions PRESET A Sets the A limit switch PRESET B Set...

Страница 13: ...CUS Sets the focus to automatic or manual IRIS Sets the camera iris to automatic or manual BLC Enables backlight compensation for shooting a dark subject on a light background Display P AND T Shows Pa...

Страница 14: ...t LENS in this section it is necessary to indicate to the camera which type of lens you are using so that it can control it correctly MANUAL fixed aperture lens The camera will use the electronic iris...

Страница 15: ...horizontally and vertically DPC Digital signal control LANGUAGE Change the menu language It is possible to set Italian even if in this manual we show the English language FORMAT It is possible to defi...

Отзывы: