background image

INSTALLATION GUIDE      

ISTART 3 AM / FM

TABLE 2

FONCTIONS

DEFAULT

PRESS LOCK

PRESS UNLOCK

PRESS 3

RD

 BUTTON

PRESS START

2.01

Trunk Pulse ( Mute)

Regular pulse

Latch when hold

Latch toggled by TX

5 sec pulse

2.02

Sliding Doors Aux 2 (unlock 1.5 sec)

Regular pulse

Latch when hold

Latch toggled by TX

5 sec pulse

2.03

Sliding Doors Aux 1 (unlock 1.5 sec)

Regular pulse

Latch when hold

Latch toggled by TX

5 sec pulse

2.04

Trigger Input

Trunk

Start Trigger input

2.05

Valet / Override

Via push button

6 times Foot Brake

2.06

Fuel Type Selection

Gas

Diesel (Go to 2.07 & 2.8)

2.07

Diesel Mode Selection

Timer diesel

Glow plug*

2.08

Diesel Timer Selection

 8 sec

 12 sec 

15 sec 

20 sec

2.09

When Remote Start Door Relock

Disable

Enable

Enable after start only

2.10

Numbers of Tries for Start Attempt

One try

Two tries*

Three tries*

2.11

Turbo mode timer adjustment*

45 sec* 

60 sec* 

90 sec*

120 sec*

2.12

AUX Output Selection

Trunk release

Sliding Doors & Trunk Enable

2.13

Domelight supervision

45 seconds

20 seconds

Parking lights

Horn

2.14

Trunk input detect for manual 

transmission*

Disable*

Enable*

2.15

Telematic start / stop with separate 

button

Disable

Enable

2.16

Re-arm when shut off

Enable

Disable

TABLE 3

FONCTIONS

DEFAULT

PRESS LOCK

PRESS UNLOCK

PRESS 3

RD

 BUTTON

PRESS START

3.01

Horn / Siren Selection

Horn

Siren

3.02

Horn Setting

Default

Extended

Extended - 3ms

Ex3ms

3.03

Horn / Siren Confirmation

Chirp Enable

Chirps only when lock button 

is pressed a second time

Full mute

Mute only on

Unlock

3.04

Horn / Siren Ignition Monitor

Disable

Enable

3.05

Start Mode for TX

Regular Start

Safe Start Press Lock then Start

Safe Start

Press Start 2 Times

3.06

Safety Auto Relock

Enable with Alarm mode

Disable with Alarm mode

Enable with no alarm

(door input must be

connected)

3.07

Pulse Before Ignition

1.5 sec 

0.5 sec

3 sec

3.08

Ignition Valet Mode

when system is disarmed only

Disable

Enable Ignition On 5 times

3.09

*Manual transmission setting

(see 3.15 & 3.16)

*Auto shut off

*Shut off by remote

FB On/ HB On/ FB Off/

Key Off/ Exit/ Eng shut

in 10sec

3.10

10/20 sec delay exit mode

With door lock*

Without door lock*

3.11

Unlock Driver Door

Disable

Enable

To be used only with RS232 Data Port

3.12

Passkey Output Selection

Passkey Secure

Non-Secure

To be used only with RS232 Data Port

3.13

Protocol unlock while remote start

Disable

Enable

To be used only with RS232 Data Port

3.14

Manual Setting Cranking*

Standard Crank*

Ove2 sec*

3.15

Manual transmission: unlock 

before exit

Enable

Disable

3.16

Manual transmission: silent mode

Disable

Enable

TABLE 4

FONCTIONS

DEFAULT

PRESS LOCK

PRESS UNLOCK

PRESS 3

RD

 BUTTON

PRESS START

4.01

Passkey Output Programming 

Options

Passkey Standard

Stay ground with ignition

3

rd

 Ignition

3

rd

 Start

4.02

Rearm Wire Output

Programming Options

2003 GM Disable

Enable to remote lock when

engine running

4.03

Domelight Bypass

Disable

Enable

4.04

Dome Diagnostic 4 Chirp

Enable

Disable

4.05

Crank Time Adjustments*

Min cranking 0.7 sec*

Min cranking 0.9 sec*

1.2 sec*

1.5 sec*

4.06

Crank Time Adjustments*

Max cranking 10 sec*

Max cranking 3.5 sec*

4.07

N/A

N/A

N/A

4.08

Engine shut off when voltage drop

below

13.25V

13V

12.75V

12.5V

4.09

Tachless cranking adjustment

Default

5% Less

5% More

10% More

4.10

Mute Button Selection

Mute

Trunk

Stop

4.11

White / Green Wire

Key sense

Temperature Sensor input

4.12

Temperature Sensor

Disable

-20 degree C

-25 degree C

4.13

ACC relay selection

ACC(+) / ACC (-)

 IGN(+) / IGN (-)

START (+) / (-)  

PASSKEY (+) / (-)

4.14

ARM pulse

 Standard

Before lock pulse

4.15

Disarm / Unlock

Standard

Ign

Acc+Ign

Acc

4.16

Parking light off after 3 minutes

Disable

Enable

Version AI3-F

Note: Choosing option 1.15 Quick Start, all the subsequent options with an * are no longer available.

Содержание ISTART 3 AM / FM

Страница 1: ...es manettes existantes devront tre cod es en m me temps APPRENTISSAGE DU SIGNAL DE TACH OBLIGATOIRE D marrer avec la cl laisser tourner le moteur au ralenti Appuyer et tenir les boutons Barrer et D ba...

Страница 2: ...Une fois que la table est choisie appuyer le bouton de programmation le nombre de fois quivalent l option choisie Les feux de position et le klaxon se manifestent chaque fois que le bouton est appuy...

Страница 3: ...ois Activ Ignition On 5 Fois 3 09 R glage du mode transmission manuelle Voir option 3 15 3 16 Moteur arr t la fermeture de porte Moteur arr t par t l commande avec d lai de 2 min P dale frein frein ma...

Страница 4: ...e Sir ne Klaxon 1 Amp Mauve Passkey Blanc clairage du plafonnier ENTR E Bleu Noir Glow Plug Bleu Rouge Glow Plug Rouge Blanc Freins Blanc Bleu Frein d urgence main Orange Blanc Interrupteur de porte o...

Страница 5: ...nsmitters in the same time or the older transmitters will be bumped off for security reason TACH LEARNING MANDATORY Key Start LED stays solid Press and hold the Lock Unlock buttons on the remote trans...

Страница 6: ...emote button accordingly to the selected feature TO SELECT ANOTHER TABLE Repeat points 3 4 5 6 TO EXIT PROGRAMMING MANDATORY Repeat points 2 3 Parking lights will flash 5 times to confirm the end of t...

Страница 7: ...connected 3 07 Pulse Before Ignition 1 5 sec 0 5 sec 3 sec 3 08 Ignition Valet Mode when system is disarmed only Disable Enable Ignition On 5 times 3 09 Manual transmission setting see 3 15 3 16 Auto...

Страница 8: ...e Ignition Blue White Starter kill Grey Pulse to re arm Pink Siren Horn 1 Amp Purple Passkey White Domelight Supervision INPUT Blue black Glow Plug Blue Red Glow Plug Red White Brake pedal White Blue...