DIMENSIONS AND MOUNTING
For flat surface mounting in a Type 1 enclosure to meet UL requirements
DIMENSIONS
240.0mm x 181.1mm x 41.7mm (9.4” x 7.1” x 1.6”)
PANEL CUTOUT
:
220mm x 160mm (8.7” x 6.3”)
ADJUSTABLE PARAMETERS (Configuration editor)
Section
Parameter as shown on display
Factory Settings
DISPLAY
Contrast
0%
Language
English
LCD Page Timer
0h 0m 0s
Auto Scroll Delay
0h 0m 0s
Current Date and time
hh:mm
EDITOR
Alt Config
Default Config
ENGINE
Oil Pressure Low Shutdown
0.00bar
Oil Pressure Low Pre Alarm
0.00bar
Coolant Temperature Low Warning
0ºC (if configured)
Coolant Temperature High Pre Alarm
0ºC
Coolant Temperature High Shutdown
0ºC
Start Delay Off Load
0h 0m 0s
Start Delay On Load
0h 0m 0s
Start Delay Mains Fail
0h 0m 0s
Start Delay Telemetry
0h 0m 0s
Pre Heat Timer
0h 0m 0s
Crank Duration Timer
0m 0s
Crank Rest Timer
0m 0s
Safety On Delay
0m 0s
Smoke Limiting
0m 0s
Smoke Limiting Off
0m 0s
Warm Up Timer
0m 0s
Cool Down Time
0h 0m 0s
Engine Under Speed Shutdown
Active / Inactive
Engine Under Speed Shutdown
0 rpm
Engine Under Speed Warning
Active / Inactive
Engine Under Speed Warning
0 rpm
Engine Over Speed Warning
Active / Inactive
Engine Over Speed Warning
0 rpm
Engine Over Speed Shutdown
0 rpm
Engine Speed Overshoot Delay
0m 0s
Engine Speed Overshoot
0%
Fail To Stop Delay
0m 0s
Battery Under Voltage Warning
Active / Inactive
Battery Under voltage Warning Delay
0h 0m 0s
Battery Under Voltage
0 V
Battery Over Voltage Warning
Active / Inactive
Battery Over Voltage Warning Delay
0h 0m 0s
Battery Over Voltage Warning
0 V
Charge Alternator Failure Warning
Active / Inactive
Charge Alternator Failure Warning
0 V
Charge Alternator Warning Delay
0h 0m 0s
Charge Alternator Failure Shutdown
Active / Inactive
Charge Alternator Failure Shutdown
0.0 V
Charge Alternator Shutdown Delay
0h 0m 0s
DPTC Auto Regeneration Inhibit
Active / Inactive
Fuel Usage Alarm (Running Rate)
0% - 100%
Fuel Usage Alarm (Stopped Rate)
0% - 100%
Droop control
Active / Inactive
Droop control
0%
GENERATOR
Generator Under Voltage Shutdown
0 V
Generator Under Voltage Pre Alarm
0 V
Generator Nominal Voltage
0 V
Generator Over Voltage Pre Alarm
0 V
Generator Over Voltage Shutdown
0 V
Generator Under Frequency Shutdown
0 Hz
Generator Under Frequency Pre Alarm
0 Hz
Generator Nominal Frequency
0 Hz
Generator Over Frequency Pre Alarm
0 Hz
Generator Over Frequency Shutdown
0 Hz
Full Load Rating
0 A (If Configured)
KW Overload Trip
0%
Delayed Over Current
Active / Inactive
Delayed Over Current
0%
AC System
3 Phase, 4 Wire
CT Primary
0 A
CT Secondary
0 A
Generator transient delay
0s
ACCESSING THE ‘RUNNING’ CONFIGURATION EDITOR
•
The ‘running’ editor can be entered while the engine is running. All protections remain active if the
•
engine is running while the running editor is entered.
•
Press and hold the
button to enter the running editor.
EDITING A PARAMETER
•
Enter the editor as described above.
•
Press the left or right buttons to cycle to the section you wish to view/change.
•
Press the up
or down
buttons to select the parameter you wish to view/change within the currently
selected section.
•
To edit the parameter, press
to enter edit mode. The parameter begins to flash to indicate that
you are editing the value.
•
Press the up
or down
buttons to change the parameter to the required value.
•
Press
to save the value. The parameter ceases flashing to indicate that it has been saved.
•
To exit the editor at any time, press and hold the
button.
ADJUSTABLE PARAMETERS (Running editor)
Section
Parameter as shown on display
Factory Settings
DISPLAY
Contrast
0%
Language
English
ENGINE
Manual Frequency Trim
0.0Hz
Droop
Inactive / Active
Droop
0%
DPTC Auto Regen Inhibit
Inactive / Active
DPTC Manual Regen
Inactive / Active
Front Panel Configuration Editor (continued)
Section
Parameter as shown on display
Factory Settings
TIMERS
LCD Page Timer
0h 0m 0s
Auto Scroll Delay
0h 0m 0s
Pre Heat Timer
0m 0s
Crank Duration Timer
0m 0s
Crank Rest Timer
0m 0s
Safety On Delay
0m 0s
Smoke Limiting
0m 0s
Smoke Limiting Off
0m 0s
Warm Up Timer
0h 0m 0s
Cool Down Timer
0h 0m 0s
Speed Overshoot Delay
0m 0s
Fail To Stop Delay
0m 0s
Battery voltage Low Warning Delay
0h 0m 0s
Battery Voltage High Warning Delay
0h 0m 0s
Return Delay
0h 0m 0s
Generator Transient Delay
0s
Mains Transient Delay
0m 0s
Mains Transfer Time
0.0s
SCHEDULE
Schedule
Active / Inactive
Schedule On Load
Active / Inactive (only available when Scheduler is active)
Schedule Period
Weekly, Monthly, (only available when Scheduler is active
Schedule time and Date Selection (1-16)
Press
to begin editing then up or down
when selecting the
different parameters in the scheduler.
Содержание DSE7210
Страница 41: ...DSE7200 7300 Series Operators Manual 41 4 3 1 7210 AUTOSTART CONTROLLER 3 phase 4 wire...
Страница 42: ...DSE7200 7300 Series Operators Manual 42 4 3 2 7220 AMF CONTROLLER 3 phase 4 wire...
Страница 121: ...This page is intentionally blank 121...
Страница 122: ...This page is intentionally blank 122...
Страница 128: ...DSECONTROL Gu a de Utilizaci n R pida DSE7000 057 101 Autor John Ruddock...