FEATURES
SPECIFICATION
DC SUPPLY
CONTINUOUS VOLTAGE RATING
8 V to 35 V Continuous
CRANKING DROPOUTS
Able to survive 0 V for 50 mS, providing
supply was at least 10 V before dropout and
supply recovers to 5 V. This is achieved
without the need for internal batteries.
LEDs and backlight will not be maintained
during cranking.
MAXIMUM OPERATING CURRENT
340 mA at 12 V, 160 mA at 24 V
MAXIMUM STANDBY CURRENT
160 mA at 12 V, 80 mA at 24 V
CHARGE FAIL/EXCITATION RANGE
0 V to 35 V
MAINS (UTILITY) DSE7220 ONLY
VOLTAGE RANGE
15 V - 333 V AC (L-N)
FREQUENCY RANGE
3.5 Hz to 75 Hz
OUTPUTS
OUTPUT A (FUEL)
15 A DC at supply voltage
OUTPUT B (START)
15 A DC at supply voltage
OUTPUTS C & D
8 A 250 V (Volt free)
AUXILIARY OUTPUTS E,F,G,H
2 A DC at supply voltage
GENERATOR
VOLTAGE RANGE
15 V - 333 V AC (L-N)
FREQUENCY RANGE
3.5 Hz to 75 Hz
MAGNETIC PICK UP
VOLTAGE RANGE
+/- 0.5 V to 70 V
FREQUENCY RANGE
10,000 Hz (max)
DIMENSIONS
OVERALL
240 mm x 181 mm x 42 mm
9.4” x 7.1” x 1.6”
PANEL CUT-OUT
220 mm x 160 mm
8.7” x 6.3”
MAXIMUM PANEL THICKNESS
8 mm
0.3”
OPERATING TEMPERATURE RANGE
-30
°
C to +70
°
C
STORAGE TEMPERATURE RANGE
-40
°
C to +80
°
C
DEEP SEA ELECTRONICS PLC UK
Highfield House, Hunmanby Industrial Estate, Hunmanby YO14 0PH
TELEPHONE
+44 (0) 1723 890099
FACSIMILE
+44 (0) 1723 893303
WEBSITE
www.deepseaplc.com
DEEP SEA ELECTRONICS INC USA
3230 Williams Avenue, Rockford, IL 61101-2668 USA
TELEPHONE
+1 (815) 316 8706
FACSIMILE
+1 (815) 316 8708
WEBSITE
www.deepseausa.com
RELATED MATERIALS
TITLE
PART NO’S
DSE7210 Installation Instructions
053-026
DSE7220 Installation Instructions
053-027
DSE7200/7300 Quick Start Guide
057-101
DSE7200/7300 Operator Manual
057-074
DSE7200/7300 Configuration Suite PC Manual
057-077
055-081/08/10 (12) US
Registered in England & Wales No.01319649
VAT No.316923457
Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to change
the details shown on this data sheet without prior notice. The contents are intended for guidance only.
KEY FEATURES
•
4-Line back-lit LCD text display
•
Five key menu navigation
•
Front panel editing with PIN
protection
•
Customisable status screens
•
Power save mode
•
6 configurable inputs
•
8 configurable outputs
•
Configurable timers and alarms
•
3 configurable maintenance
alarms
•
Multiple date and time scheduler
•
Configurable event log (100)
•
Tier 4 CAN engine support
•
Integral PLC editor
•
Easy access diagnostic page
•
CAN and Magnetic Pick-up/Alt.
sensing
•
Fuel usage monitor and low fuel
alarms
•
Charge alternator failure alarm
•
Manual speed control (on
compatible CAN engines)
•
Manual fuel pump control
•
Engine exerciser
•
“Protections disabled” feature
•
kW & kV Ar overload protection
•
Reverse power (kW & kV Ar)
protection
•
LED and LCD alarm indication
•
Power monitoring (kW h, kV Ar,
kV A h, kV Ar h)
•
Load switching (load shedding
and dummy load outputs)
•
Automatic load transfer (DSE7220)
•
Unbalanced load protection
•
True dual mutual standby with load
balancing timer (DSE7210 only)
•
USB connectivity
•
Backed up real time clock
•
Fully configurable via DSE
Configuration Suite PC software
•
Configurable display languages
•
Remote SCADA monitoring via
DSE Configuration Suite PC
software
KEY BENEFITS
•
132 x 64 pixel ratio display for
clarity
•
Real-time clock provides
accurate event logging
•
Multiple date and time scheduler
•
Set maintenance periods can
be configured to maintain
optimum engine performance
•
Licence-free PC software
•
IP65 rating (with supplied
gasket) offers increased
resistance to water ingress
•
PLC editor allows user
configurable functions to meet
specific application
requirements
Содержание DSE7210
Страница 41: ...DSE7200 7300 Series Operators Manual 41 4 3 1 7210 AUTOSTART CONTROLLER 3 phase 4 wire...
Страница 42: ...DSE7200 7300 Series Operators Manual 42 4 3 2 7220 AMF CONTROLLER 3 phase 4 wire...
Страница 121: ...This page is intentionally blank 121...
Страница 122: ...This page is intentionally blank 122...
Страница 128: ...DSECONTROL Gu a de Utilizaci n R pida DSE7000 057 101 Autor John Ruddock...