6
6.1
Programming Access Codes
There are 9 access codes programmable by the end user. All codes have the ability to arm and disarm the
system. Instructions for programming access codes are located in the WLS920 Instruction Manual.
The user-programmed codes are as follows:
Master Code – Access Code (40)
By default, the Master Code is enabled to perform any keypad function. This code can be used to program all
User Codes. This code can also be programmed by the installer in programming section [007].The Master
Code can only be changed by the Installer.
General Access Codes – Access Codes (01) to (08)
General access codes can arm and disarm the system. By selecting the
No Code Required for Bypassing
option, each user can also have the ability to bypass zones without entering an access code. To limit the
bypassing ability for a user, disable the bypassing attribute for that user code (see “Programming Access
Codes” in the WLS920 Instruction Manual).
The Master code and the Installer’s code are programmed in Installer’s programming.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
No Code Required For Bypassing ............................... Section [015], Option [5]
Installer’s Code ............................................................................... Section [006]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Master Code ................................................................................... Section [007]
6.2
Telephone Line Monitor (TLM)
The panel will supervise the presence of the phone line and will indicate a trouble condition if the phone line is
disconnected. If the
TLM Enabled
option is selected, the panel will wait for the
TLM Trouble Delay
time
period before indicating the trouble so that a momentary interruption of the phone line will not cause a trouble
condition.
If the
TLM Trouble Only When Armed
option is enabled, the panel will indicate a TLM trouble only at the
control unit if the system is armed. To activate the bell output in the case of a TLM trouble while the system is
armed, the
TLM Audible When Armed
option must be selected.
When the trouble condition is restored, the panel can send a
TLM Restoral
Reporting Code. Any events which
occur while the phone line is down will also be communicated.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
TLM Enable/Disable ..................................................... Section [015], Option [7]
TLM Trouble Only When Armed or
TLM Audible When Armed ........................................... Section [015], Option [8]
TLM Trouble Reporting Code ......................................................... Section [349]
TLM Restoral Reporting Code ....................................................... Section [350]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
TLM Trouble Delay .......................................................................... Section [370]
6.3
Bell Cut-off
The siren will silence after the number of seconds programmed for the
Bell Cut-off
time have passed.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Bell Cut-off ...................................................................................... Section [005]
6.4
Test Transmission
To ensure that the communication link with the central station is functioning properly, the panel can be
programmed to send a test transmission signal on a regular basis.
The panel can send a
Periodic Test Transmission Reporting Code
at the programmed
Test Transmission
Time of Day
. The
Test Transmission Cycle
determines the number of days (001 to 255) between tests. If the
test transmission cycle being programmed is of a lesser value than the previous value, the system will wait the
original period before the next test transmission is sent, and then begin reporting with the new interval.
The end user can generate a communicator test. If the
System Test Reporting Code
is programmed, the
panel will send the signal when the System Test command is entered (see the WLS920 Instruction Manual for
information on performing a System Test).
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Test Transmission Reporting Codes .............................................. Section [352]
Test Transmission Time of Day ....................................................... Section [371]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Test Transmission Cycle ................................................................. Section [370]