Zone Programming

s

e

c

t

i

o

n

5

5.1

Zone Definitions

Program section [001] to select how each of the zones will operate. Each zone requires a two digit entry. In
addition to zone definitions, six different attributes may be programmed by zone (see Section 5.2 – “Zone
Attributes”).

[00]  Null Zone

The zone is vacant. Unused zones should be programmed as Null zones.

[01]  Delay 1

This zone type, normally used for entry/exit doors, can be violated during the exit delay time without causing
an alarm. Once the exit delay has expired, opening the zone will start the entry delay timer. During the entry
delay time, the buzzer will sound steadily to advise the user that the system should be disarmed. If the panel is
disarmed before the entry time expires, no alarm will be generated.

[02]  Delay 2

The Delay 2 entry delay time can be set independent of Delay 1 in programming section [005] (System Times).

[03]  Instant Zone

This zone type will cause an instant alarm if it is violated when the panel is armed. Typically, this zone is used
for windows, patio doors or other perimeter zones.

[04]  Interior Zone

This zone will not cause an alarm if violated during the entry delay. If the zone is violated before the entry
delay has begun, it will cause an instant alarm. Typically, this zone is used for interior protection devices, such
as motion detectors.

[05]  Interior Stay/Away Zone

This zone type works similar to the Interior zone type except that it will be automatically bypassed under the
following conditions:
• When the panel is armed in the Stay Mode, i.e. when the panel is armed with a user code and a Delay type

zone is NOT tripped during the exit delay.

• When the panel is armed without entry delay, see section 6.11 “[

] Commands”.

The automatic bypass prevents the user from having to manually bypass interior type zones when arming at
home. This zone is typically used for interior protection devices, such as motion detectors.

[06]  Delay Stay/Away Zone

This zone type will operate similar to Interior Stay/Away zones except that it will always provide an entry delay.
Typically, this zone is used for interior protection devices, such as motion detectors. This zone option will help
prevent false alarms since it always provides an entry delay time for the user to turn off the panel.

[07] - [09] Not used

[10]  24 Hour Supervisory Buzzer Zone

If this zone is violated when the system is either armed or disarmed, the panel will immediately latch the
buzzer until a valid user code is entered and will immediately communicate to the central station.

[11]  24 Hour Burglary Zone

If this zone is violated when the system is either armed or disarmed, the panel will immediately latch the alarm
output and communicate to the central station. The alarm will sound for the Bell Cutoff time programmed in
Section [005] (“System Times”) or until a valid user code is entered.

[12] 24 Hour Holdup/Panic  Zone

This zone is similar to the 24 Hour Burglary zone type, except for the SIA identifier.

[13] - [24]  Not used

[87]  Not used

[88]  Standard 24 Hour Fire Zone

When this zone is violated, the panel will immediately latch the alarm output and communicate to the central
station. The alarm will sound for the Bell Cutoff time programmed in Section [005] (“System Times”).
A violated Fire zone will be displayed.

○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

Zone Definitions ............................................................................. Section [001]

Содержание WLS920

Страница 1: ...Installation Manual W A R N I N G This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer The entire...

Страница 2: ...0 25 AVIS L tiquettedel IndustrieCanadaidentifielemat rielhomologu Cette tiquettecertifiequelemat rielestconforme certainesnormesdeprotection d exploitation et de s curit des r seaux de t l communica...

Страница 3: ...re Connections Power and Telephone 4 3 2 Adding Wireless Devices 4 3 3 Deleting Wireless Devices 4 3 4 Module Placement Test 5 3 5 Supervision 5 Section 4 Communications Programming 6 4 1 Dialing 6 4...

Страница 4: ...kout 14 6 9 Swinger Shutdown 14 6 10 International Programming Options 14 6 11 Commands 14 6 12 Wireless Key Programming 16 Programming Worksheets 18 Basic Programming 18 Communicator Programming 19 I...

Страница 5: ...ries 30 to 36 month life Fully supervised for communication integrity 12 minute supervisory time Tamper condition is monitored Photoelectric detection technology Patent pending Internal diagnostic eve...

Страница 6: ...urn ON and the System light will continue to flash You can also press the key to exit a programming section without entering data for every box This is handy if you only need to change digits in the f...

Страница 7: ...u have programmed a section when that programming section is entered the control unit will immediately display the first digit of information programmed in that section The control unit will display t...

Страница 8: ...Enter Installer s Programming and enter Section 804 2 Enter the 2 digit zone number for the device 01 to 08 3 Enter the five digit electronic serial number located on the back of the wireless device...

Страница 9: ...ait at least 10 seconds between tests WLS908 Panic Pendant Test The panic pendant cannot be tested in the module placement test so follow these steps 1 Begin testing when your system is in the ready s...

Страница 10: ...First Phone Number is the primary number the Second Phone Number is the secondary number and the Third Phone Number will back up the First phone number if enabled The Third Phone Number will NOT back...

Страница 11: ...rting Code will be sent along with the closing reporting code if one or more zones were manually bypassed when the system was armed to warn the monitoring station of a security compromise If the Closi...

Страница 12: ...the AC Failure Communication Delay The AC Failure Trouble Restoral Reporting Code follows the AC failure communication delay as well If AC Failure Communications Delay is programmed as 000 then the A...

Страница 13: ...ber the fourth digit must be programmed as 0 3 digit account number 123 program 1230 3 If an account number has a 0 in it substitute a HEX digit A for the 0 For example 3 digit account number 502 prog...

Страница 14: ...to Appendix B for a list of SIA identifiers SIA Sends Automatic Reporting Codes Section 381 3 Pager Format The Communicator Format option for either phone number can be programmed as the Pager Format...

Страница 15: ...when the panel is armed with a user code and a Delay type zone is NOT tripped during the exit delay When the panel is armed without entry delay see section 6 11 Commands The automatic bypass prevents...

Страница 16: ...n Armed option is enabled the panel will indicate a TLM trouble only at the control unit if the system is armed To activate the bell output in the case of a TLM trouble while the system is armed the T...

Страница 17: ...fter Alarm Keypad Ringback Section 381 Option 1 Opening After Alarm Bell Ringback Section 381 Option 2 Bypass Status Displayed While Armed Section 016 Option 7 6 7 Entry Exit Delay Options Two differe...

Страница 18: ...or when the panel is armed Once reset the panel will again communicate normally Swinger Shutdown Section 370 6 10 International Programming Options 701 First International Option Code 1 Power Line Fre...

Страница 19: ...press 2 The System light will flash and one or more zone lights will turn ON indicating the various trouble conditions Trouble 1 Low Battery The main panel backup battery is low The trouble will be ge...

Страница 20: ...digits Enter the Time in Hours and Minutes using the 24 Hour format 00 00 to 23 59 Enter the Date in Months Days and Years MM DD YY 9 Arming Without Entry Delay When the system is armed with the 9 com...

Страница 21: ...vate Stay Away Zones Same as described in section 6 11 1 Zone Bypass Reactivate Stay Away Zones 08 15 For Future Use 27 Disarm OFF Disarms the system 28 Fire Alarm The FAP keys are only available on t...

Страница 22: ...03 I__ _____I__ _____I Zone 4 04 I_______I__ _____I Zone 8 005 System Times Default 001 255 030 I_ ______I_ ______I _ ______I Entry Delay 1 045 I_ ______I_ ______I _ ______I Entry Delay 2 120 I_ ____...

Страница 23: ...en Armed TLM Trouble Only When Armed 6 2 Option 4 must be ON in order for WLS909 Wireless Key arming to function 016 Third System Option Code Default Option ON OFF Section ON I________I 1 For Future U...

Страница 24: ...___I__ _____I Keypad Auxiliary Restoral I__ _____I__ _____I Keypad Panic Alarm I__ _____I__ _____I Keypad Panic Restoral I__ _____I__ _____I For Future Use I__ _____I__ _____I For Future Use 330 Tampe...

Страница 25: ..._____I AC Failure Trouble Alarm I_______I__ _____I For Future Use I__ _____I__ _____I Bell Circuit Trouble Alarm I_______I__ _____I For Future Use I__ _____I__ _____I Fire Trouble Alarm I_______I__ _...

Страница 26: ...ns Section 4 1 Dialing Default Option ON OFF ON I_ _______I 1 1st Telephone Number Disabled OFF I_ _______I 2 2nd Telephone Number Disabled 368 System Test Transmissions Communicator Call Directions S...

Страница 27: ...lt Option ON OFF Section OFF I_ ______I 1 Open After Alarm Kypd Ringback enabled Open After Alrm Kypd Ringback disabled 6 6 OFF I_ ______I 2 Open After Alarm Bell Ringback enabled Open After Alrm Bell...

Страница 28: ...05 l_____l_____l_____l_____l_____l 46 Wireless Key 06 l_____l_____l_____l_____l_____l 47 Wireless Key 07 l_____l_____l_____l_____l_____l 48 Wireless Key 08 l_____l_____l_____l_____l_____l 49 Wireless...

Страница 29: ...3 Zone 03 Supervision enabled Disabled l________l Option 4 Zone 04 Supervision enabled Disabled l________l Option 5 Zone 05 Supervision enabled Disabled l________l Option 6 Zone 06 Supervision enabled...

Страница 30: ...e effectiveness of these features It is important that a security system be reviewed periodically to ensure that its features remain effective and that it be updated or replaced if it is found that it...

Страница 31: ...onnection of the terminal equipment Standard jacks shall be so arranged that if the plug connected thereto is withdrawn no interference to the operation of the equipment at the customer s premises whi...

Страница 32: ...1999 Digital Security Controls Ltd 1645 Flint Road Downsview Ontario Canada M3J 2J6 Tel 416 665 8460 Fax 416 665 7498 Tech Line 1 800 387 3630 www dscgrp com Printed in Canada 29002745 R001...

Отзывы: