INSTALLATION
SECURITY ACCOUNT
FIND IT
Settings
Installation
Security
Account
Setting
Default
Description
Account Number
blank
Security provider account number (up to 10 characters)
Power Management
Enabled
An energy-saving function when running on battery power only
Power Management Sleep
Timeout
1
Panel initiates power management mode a specified number of
minutes after last touch
Power Restoration
Disabled
Turn on or off sensor hold for 60 seconds during power
restoration.
Loss of Supervisory Signals
for Emergency Sensors
4
Select the length in hours (4) before reporting a loss of
supervision on life safety devices.
Loss of Supervisory Signals
for Non Emergency Sensors
24
Select the length in hours (24) before reporting a loss of
supervision on security devices
Loss of AC Power Timeout
3
Select the length in minutes (1-10) before reporting an AC power
loss.
Loss of Cell Signal Timeout
30
Select the length in minutes (10-120) before reporting a loss in
cellular signal.
Installer Code Access
Master Code Access
DSC Confidential and Proprietary Page of
20 114
© Last updated 4/29/15 All rights reserved
Note: For UL/cUL, the wireless supervision window for Emergency sensors (Smoke detectors, CO detectors) shall be set to 4h.