![DSC Touch-SCW9067 Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/dsc/touch-scw9067/touch-scw9067_installation-manual_2534872033.webp)
SENSOR GROUPS
MOTION/IMAGE SENSOR
GROUP
NAME
SUPERVISED
SCENARIO
17
Away- Instant Motion
Y
Active only when armed to “Away”, and trips instantly when motion
is detected. Does
not
trip if an entry/exit sensor is tripped first.
15
Stay- Instant Motion
Y
Also active when armed to “Stay”, and trips instantly when motion
is detected. Does
not
trip if an entry/exit sensor is tripped first.
35
Stay- Delay Motion
Y
Also active when armed to “Stay”. Triggers an entry delay when
motion is detected. Does
not
trip if an entry/exit sensor is tripped
first.
20
Away- Delay Motion
Y
Active when armed to “Away”. Triggers an entry delay when motion
is detected. Does
not
trip if an entry/exit sensor is tripped first.
25
Safety Motion
Y
This sensor does
not
report or trigger an alarm. This is a chime only
sensor when “Safety Sensors” are active, regardless of panel status.
Used for medicine cabinets, chemical storage etc.