TROUBLESHOOTING
PANEL TEST TROUBLESHOOTING
FIND IT
Settings
System Tests
Panel Test
Installer Code Access
Master Code Access
DSC Confidential and Proprietary Page of
99 114
© Last updated 4/29/15 All rights reserved
Test
Description
If fails:
LCD Red/Green Check panel LED operation
1) Reboot the panel and run the test again.
2) Master reset and repeat test
System Data
Check panel backup software
version
1) Provide user option to create backup version on the panel.
This is NEW Requirement
Panel Tamper
Check panel Tamper state
1) Check to ensure backplate is secure and installed properly.
AC Status
Check panel AC power status
1) Inspect the wire leads are secure and properly connected on
the terminal block and adapter.
Internet
Connection
Check panel's Internet
connectivity
1) Go to Wifi Setting page, Enable Wifi and connect to a Wifi
Network
2) Make sure Internet is available on the home router. You can
check the Internet in System Monitor page.
3) Contact your network service provider on continued
internet connectivity failure.
Cell Connection
Check panel's cell network
connectivity
1) Possible OTASP provisioning required.
2) Run cell connectivity test on Settings / System Tests page
Support Mode
Check panel support mode
(adb) is disabled
1) Contact Dealer to disable ADB from Alarm.com dealer site
Содержание Touch-SCW9067
Страница 4: ...HARDWARE...
Страница 12: ...SOFTWARE...
Страница 18: ...INSTALLATION...
Страница 66: ...SYSTEM TESTS...
Страница 75: ...CUSTOMIZATION CUSTOMIZATION...
Страница 88: ...TROUBLESHOOTING...