background image

3

Installing Ethernet Communicator in Panel

Internet Alarm Communicator Installation Guide

hazardous, indoor locations only. This manual shall be used with the installation manual of the

panel which is connected to the Ethernet communicator. All instructions specified within the panel

manual must be observed.
All local rules imposed by local electrical codes shall be observed and respected during installation.

Installing the Ethernet Cable (TL2803G(R) Only)

A Category 5 (CAT 5) Ethernet cable must be run from a source with Internet connectivity to the

communicator module, inside the panel. The communicator end of the cable must be terminated

with an RJ45 plug, which will connect to the communicator’s RJ45 jack after the communicator is

installed. All requirements for installation of CAT5 Ethernet cable must be observed for correct

operation of the communicator, including, but not limited to, the following:
HSPA(3G)/Dual Alarm Communicator Installation Manual
• Do NOT strip off cable sheathing more than required for proper termination.
• Do NOT kink/knot cable.
• Do NOT crush cable with cable ties.
• Do NOT untwist CAT5 pairs more than ½ in. (1.2cm).
• Do NOT splice cable.
• Do NOT bend cable at right angles or make any other sharp bends.
NOTE: CAT5 specification requires that any cable bend must have a minimum 2 in. (5 cm) bend
radius. Maximum length of CAT 5 cable is 328 ft. (100 m).

Installing Communicator with HS2016, HS2032, HS2064, and 

HS2128 Panel

1. To assemble supplied mounting bracket, perform the following: (see 

Figure 1

).

a. Remove the 4 white plastic standoffs

from the bag provided with the com-

municator kit.

b. Insert the 4 standoffs through the back

of the mounting bracket, into the holes

at each corner.

c. Place the bracket on a flat, solid sur-

face. Hold the communicator compo-

nent side up and orient the 4 holes on

the communicator with the 4 standoffs

protruding from the bracket. Push the

communicator firmly and evenly onto

the standoffs until it is securely 

attached to the mounting bracket.

d. Remove the panel front cover.
e. Remove and discard the circular knockout located

in the top-right section of the panel.

2. Install the Communicator into the panel: 

a. Attach one end of the PC-LINK cable to the panel

PC-LINK header on the panel (red wire goes on the

right-hand pin of the 

panel

 PCLINK_2 header (see

Figure 3

)). 

b. Insert the assembled communicator into the panel.
c. Locate the screw hole on the right side wall of the

panel (see

Figure 2

(screw)). Line up the assembled

communicator with the right side wall of the panel

and, using the screw provided, secure the mounting

bracket to the panel. 

I

NSTALLING

 E

THERNET

 C

OMMUNICATOR

 

IN

 P

ANEL

Mounting

Holes

Mounting Holes

Mounting Plate
   

Communicator
Board

Mounting
Plate

Stand Off

 Figure 1: Communicator Mounting Bracket 

PC-Link cable connector

screw

GSM Radio

RJ-45

UA601

HS2016/2032/2064/2128

 Figure 2:HS2016/2032/2064/2128 Panel

Содержание TL280R

Страница 1: ...ernational INSTALLATION GUIDE V4 1 For installation manual visit www dsc com Warning This manual contains information on limitations regarding product use and function and information on the limitatio...

Страница 2: ...ion Configuration 2 Installing Ethernet Communicator in Panel 3 Initial Panel Programming 5 Communicator Status LEDs 5 Communicator Troubleshooting 6 Ethernet Programming Options 7 Ethernet Programmin...

Страница 3: ...the occupants or their belongings Motion Detectors Motion detectors can only detect motion within the designated areas as shown in their respective installation instructions They cannot discriminate...

Страница 4: ...device operation Model Information This manual covers the following model of alarm communicator TL280 and TL280R References to model TL280 R throughout this manual applies to all specified models unle...

Страница 5: ...his Ethernet Communicator shall be installed by service persons only service person is defined as a person having the appropriate technical training and experience necessary to be aware of haz ards to...

Страница 6: ...of CAT 5 cable is 328 ft 100 m Installing Communicator with HS2016 HS2032 HS2064 and HS2128 Panel 1 To assemble supplied mounting bracket perform the following see Figure 1 a Remove the 4 white plast...

Страница 7: ...n manual for the 3rd party device for wiring instructions Wire the RS 422 connections as per the table below NOTE The GND connection is optional DSC recommends connecting GND wire at both ends Install...

Страница 8: ...ections 311 318 Partition Call Directions program the call direction options for the system 6 In panel section 401 DLS SA Options set toggle option 2 User Enable DLS to ON in order to perform panel DL...

Страница 9: ...lashes 06 Ethernet Trouble Check with your ISP to confirm Internet service is active in your area Ensure your Ethernet cable is securely inserted into the RJ45 jack of the communicator and the hub rou...

Страница 10: ...is still initializing please wait while the unit gets its programming and establishes a connection to all programmed receivers NOTE This process may take several minutes to complete Boot Loader Faile...

Страница 11: ...____ ____ ____ ____ ____ ____ ____ Programming Options 010 System Toggle Options 3 ____ 1 Reserved ____ 2 Visual Verification Default OFF ____ 3 Reserved 011 Installer Code Default CAFE Valid range 00...

Страница 12: ...____ 104 Ethernet Receiver 1 UDP Remote Port Default 0BF5 3061 Valid range 0000 FFFF ____ ____ ____ ____ 105 Ethernet Receiver 1 UDP Local Port Default 0BF4 3060 Valid range 0000 FFFF ____ ____ ____...

Страница 13: ...000 FFFF ____ ____ ____ ____ 698 Integration Outgoing Port Default 0C04 Valid range 0000 FFFF ____ ____ ____ ____ 699 Integration Incomming Port Default 0BFF Valid range 0000 FFFF ____ ____ ____ ____...

Страница 14: ...cts disassembled or repaired in such a manner as to adversely affect performance or prevent adequate inspection or testing to verify any warranty claim Access cards or tags returned for replacement un...

Страница 15: ...printed materials any upgrades and this EULA and provided the recipient agrees to the terms of this EULA If the SOFTWARE PRODUCT is an upgrade any transfer must also include all prior versions of the...

Страница 16: ...UHOHYDQWHV GD LUHFWLYD 63 3RU OD SUHVHQWH 6 GHFODUD TXH HVWH HTXLSR HVW HQ FRQIRUPLGDG FRQ ORV UHTXLVLWRV HVHQFLDOHV RWURV UHTXLVLWRV UHOHYDQWHV GH OD LUHFWLYD 6 6 EHNU IWDU K UPHG DWW GHQQD DSSDUDW...

Отзывы: