7
Ethernet Programming Options
Internet Alarm Communicator Installation Guide
The programming sections described in this document can be viewed at the keypad LCD. To start
programming enter:
[*][8][installer code][851][section number]
, where section number is the 3
digit section number referenced in this section. The programming worksheets at the end of this
document can be used to record the new values when programming changes have been made from
the default values.
Red and Yellow
LEDs flashing
together
N/A
Initialization
Sequence
• The unit is still initializing please wait while the unit gets its programming
and establishes a connection to all programmed receivers.
NOTE: This process may take several minutes to complete.
Boot Loader
Failed
• If the initialization sequence is taking more than several minutes, the boot
loader might have failed.
• Confirm that the boot loader has failed by entering communicator program-
ming
[*][8][installer code][851]
.
• If access is granted, continue waiting for the initialization sequence to com-
plete.
• If access is denied (long error tone), disconnect power from, then recon-
nect power to the communicator module.
E
THERNET
P
ROGRAMMING
O
PTIONS
Table 6: Trouble indications
Trouble
indication
Trouble
Indicator
Digit
Possible
Causes
Trouble Possible Solution