2
Maximum System Capabilities
■
Control Units - 1 PC4000 Main Board
■
128 Zones
PC4000 Main Board: 16 zones
PC4108 Expansion Module: 8 zones
PC4116 Expansion Module: 16 zones
■
64 High Current Outputs - Up to 16 PC4204 Modules
■
144 Low Current Outputs
- 9 PC4216 16 Output Modules
■
1 RS-232 Interface - PC4400
■
16 Remote LCD Keypads - LCD-4500
■
1 Main Board Fully Programmable Output
■
1 12 VDC Switched Fully Programmable Auxiliary
Power Supply (Main Board)
■
1 Supervised Fully Programmable Bell / Siren Output
(Main Board)
■
1 Telephone Interface (Main Board)
128 Programmable Zones
■
16 zones on main board expandable by using 8 and
16 zone modules
■
Several zone types including: instant, 2 types of
interior, 3 delay, 3 fire, 4-24 hour, forced answer,
momentary, and maintained arming
■
Zone expansion is done by enrolling an expansion
module
■
Zones can be assigned independently to any
partition(s)
LCD Keypads (LCD-4500)
■
Total of 16 on the system
■
Can be assigned to any partition
209 Outputs
■
1 main board transistor switch to ground with 3A
capabilities (programmable for 1 of 23 options)
■
64 relay outputs programmable for 1 of 23 options
each (16-4204 modules with 4 outputs each)
■
16 switched transistor outputs programmable for 1 of
23 options each (1-4216 module with 16 outputs)
■
128 alarm status indicators (8-4216 modules with 16
outputs each)
Switched Auxiliary Output
■
Programmable for 1 of 23 options
Supervised Alarm Output
■
Bell Output, 700 mA fused at 5 Amps, 12 VDC
unregulated
❶
■
Steady or Pulsed Output
■
Programmable for 1 of 23 options
Event Buffer
■
512 events
■
Date and time stamp
8 True Partitions
■
Separate or shared zones from other partitions
■
Individual keypads per partition (minimum 1 keypad)
■
Individual access codes for each partition
■
Individual keypad zones (Fire, Emergency, Panic)
■
Individual outputs programmable per partition
RS-232 Interface Module (PC4400)
■
Used to output data to a local printer
Internal Memory
■
Retains programmed data even when both AC and
Battery have been removed.
■
The clock will have to be reset after a power down
condition which will be indicated by an audible trouble.
Keypad User Options
They are all menu driven, including:
■
Programming of up to 11 types of security codes, 128
in total
■
Bypassing from the keypad by authorized personnel
■
Utility functions such as remote control of lights, door
strikes, etc.
Communicator
■
Communicates in all 10 and 20 BPS single line and
extended formats
■
Radionics Rounds and Radionics Parity
■
Sescoa Superfast format
■
Ademco Contact ID format
■
SIA 1986 format
■
Surgard 4/3 DTMF format
■
3/1 and 4/2 formats
■
Hexadecimal numbers
■
DTMF and Pulse dialing
■
DPDT line seizure
■
True dial tone detect
■
Anti-jam feature
■
Three telephone numbers and nine account codes
■
Split reporting
SYSTEM OVERVIEW
❶
Values shown
Содержание SYSTEM MASTER PC4000
Страница 1: ...SYSTEM MANUAL PC4OOO Book 4 Jan 11 1993 Software Version 1 3 ...
Страница 8: ......
Страница 10: ......
Страница 12: ......
Страница 13: ...11 ...
Страница 14: ...12 ...
Страница 16: ......
Страница 24: ......
Страница 29: ... 1993 Digital Security Controls Ltd Toronto Canada Tel 800 387 3630 FAX 905 760 3034 ...
Страница 30: ...29000223R0 ...