This manual is for the PC4000 software version 1.3.

DOC NOTICE

NOTICE:

 

The Canadian Department of Communications label identifies certified

equipment. This certification means that the equipment meets certain
telecommunications network protective, operational and safety requirements. The
Department does not guarantee the equipment will operate to the user's satisfaction.

Before installing this equipment, users should ensure that it is permissible to be
connected to the facilities of the local telecommunications company. The equipment
must also be installed using an acceptable method of connection. In some cases, the
company's inside wiring associated with a single line individual service may be
extended by means of certified connector assembly (telephone extension cord). The
customer should be aware that compliance with the above conditions may not
prevent degradation of service in some situations.

Repairs to certified equipment should be made by an authorized Canadian
maintenance facility designated by the supplier. Any repairs or alterations made by
the user to this equipment, or equipment malfunctions, may give the
telecommunications company cause to request the user to disconnect the equipment.

User should ensure for their own protection that the electrical ground connections of
the power utility, telephone lines and internal metallic water pipe system, if present,
are connected together. This precaution may be particularly important in rural areas.

CAUTION:

 

 Users should not attempt to make such connections themselves, but

should contact the appropriate electric inspection authority, or electrician, as
appropriate.

The 

Load Number

 (LN) assigned to each terminal device denotes the percentage of

the total load to be connected to a telephone loop which is used by the device, to
prevent overloading. The termination on a loop may consist of any combination of
devices subject only to the requirement that the total of the Load Numbers of all the
devices does not exceed 100.
The Load Number of this device is 10.

AVIS: 

 L'étiquette du ministère des Communications du Canada identifie le matériel

homologué. Cette étiquette certifie que le matériel est conforme à certaines normes
de protection, d'exploitation et de sécurité des réseaux de télécommunications. Le
Ministère n'assure toutefois pas que le matétiel fonctionnera à la satisfaction de
l'utilisateur.

Avant d'installer ce matériel, l'utilisateur doit s'assurer qu'il est permis de le
raccorder aux installations de l'entreprise locale de télécommunication. Le matériel
doit également être installé en suivant une méthod acceptée de raccordement. Dans
certains cas, les fils intérieurs de l'entreprise utilisés pour un service individuel a
ligne unique peuvent être prolongés au moyen d'un dispositif homologué de
rassordement (cordon prolongateur tèlèphonique interne). L'abonné ne doit pas
oublier qu'il est possible que la conformité aux conditions énoncées ci-dessus
n'empechent pas la dégradation du service dans certaines situations. Actuellement,
les entreprises de télécommunication ne permettent pas que l'on raccorde leur
matériel a des jacks d'abonné, sauf dans les cas précis prévus par les tarrifs
particuliers de ces entreprises.

Les réparations de matériel homologué doivent etre effectuées par un centre
d'entretien canadien autorisé désigné par le fournisseur. La compagnie de
télécommunications peut demander à l'utilisateur de débrancher un appareil à la suite
de réparations ou de modifications effectuées par l'utilisateur ou à cause de mauvais
fonctionnement.

Pour sa propre protection, l'utilisateur doit s'assurer que tous les fils de mise à la
terre de la source d'énergie électrique, des lignes téléphoniques et des canalisations
d'eau métalliques, s'il y en a, sont raccordés ensemble. Cette précaution est
particulièrement importante dans les régions rurales.

AVERTISSEMENT:

  

L'utilisateur ne doit pas tenter de faire ces raccordements lui-

meme; il doit avoir recours a un service d'inspection des installations électriques, ou
à electricien, selon le cas.

L'indice de charge (IC) assigné a chaque dispositif terminal indique, pour éviter toute
surcharge, le pourcentage de la charge totale qui peut etre raccordée a un circuit
téléphonique bouclé utilisé par ce dispositif. La terminaison du circuit bouclé peut
etre constituée de n'import quelle combinaison de dispositifs, pourvu que la somme
des indices de charge de l'ensemble des dispositifs ne dépasse pas 100.
L'indice de charge de cet dispositif est 10.

FCC COMPLIANCE STATEMENT

CAUTION:

 Changes or modifications not expressly approved by Digital Security

Controls Ltd. could void your authority to use this equipment.

This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:

Re-orient the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.

Consult the dealer or an experienced radio/television technician for help.

The user may find the following booklet prepared by the FCC useful: “How to
Identify and Resolve Radio/Television Interference Problems”. This booklet is
available from the U.S. Government Printing Office, Washington D.C. 20402, Stock
# 004-000-00345-4.

IMPORTANT INFORMATION

This equipment complies with Part 68 of the FCC Rules. On the side of this
equipment is a label that contains, among other information, the FCC registration
number of this equipment.

NOTIFICATION TO TELEPHONE COMPANY

  

Upon request, the customer shall

notify the telephone company of the particular line to which the connection will be
made, and provide the FCC registration number and the ringer equivalence of the
protective circuit.

FCC Registration Number: F53CAN-73256-AL-E
Ringer Equivalence Number: 0.1B
USOC Jack: RJ-31X

TELEPHONE CONNECTION REQUIREMENTS 

 

Except for the telephone company

provided ringers, all connections to the telephone network shall be made through
standard plugs and telephone company provided jacks, or equivalent, in such a
manner as to allow for easy, immediate disconnection of the terminal equipment.
Standard jacks shall be so arranged that, if the plug connected thereto is
withdrawn, no interference to the operation of the equipment at the customer’s
premises which remains connected to the telephone network shall occur by reason
of such withdrawal.

INCIDENCE OF HARM

 

 

Should terminal equipment or protective circuitry cause

harm to the telephone network, the telephone company shall, where practicable,
notify the customer that temporary disconnection of service may be required;
however, where prior notice is not practicable, the telephone company may
temporarily discontinue service if such action is deemed reasonable in the
circumstances. In the case of such temporary discontinuance, the telephone company
shall promptly notify the customer and will be given the opportunity to correct the
situation.

ADDITIONAL TELEPHONE COMPANY INFORMATION

  

The security control

panel must be properly connected to the telephone line with a USOC RJ-31X
telephone jack.

The FCC prohibits customer-provided terminal equipment be connected to party
lines or to be used in conjunction with coin telephone service. Inter-connect rules
may vary from state to state.

CHANGES IN TELEPHONE COMPANY EQUIPMENT OR FACILITIES

  The

telephone company may make changes in its communications facilities, equipment,
operations or procedures, where such actions are reasonably required and proper in
its business. Should any such changes render the customer’s terminal equipment
incompatible with the telephone company facilities the customer shall be given
adequate notice to the effect modifications to maintain uninterrupted service.

RINGER EQUIVALENCE NUMBER (REN)

 

 The REN is useful to determine the

quantity of devices that you may connect to your telephone line and still have all of
those devices ring when your telephone number is called. In most, but not all areas,
the sum of the RENs of all devices connected to one line should not exceed five
(5.0). To be certain of the number of devices that you may connect to your line, you
may want to contact your local telephone company.

EQUIPMENT MAINTENANCE FACILITY

  

If you experience trouble with this

telephone equipment, please contact the facility indicated below for information on
obtaining service or repairs. The telephone company may ask that you disconnect
this equipment from the network until the problem has been corrected or until you
are sure that the equipment is not malfunctioning.
Digital Security Controls Ltd.    160 Washburn St., Lockport, NY 14094

Содержание SYSTEM MASTER PC4000

Страница 1: ...SYSTEM MANUAL PC4OOO Book 4 Jan 11 1993 Software Version 1 3 ...

Страница 2: ...anges or modifications not expressly approved by Digital Security Controls Ltd could void your authority to use this equipment This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generat...

Страница 3: ...04 relay output module is available for installations requiring additional power beyond the 500 mA supplied by the PC4000 main panel This module comprises a 12 volt DC power supply of 1 5 Amp capacity and four 12 volt relays with form C contacts which will provide switched outputs under any of the 23 options available in the list of programmable outputs The PC4204 connects to the COMBUS via four w...

Страница 4: ...indicators 8 4216 modules with 16 outputseach Switched Auxiliary Output Programmable for 1 of 23 options Supervised Alarm Output Bell Output 700 mA fused at 5 Amps 12 VDC unregulated Steady or Pulsed Output Programmable for 1 of 23 options Event Buffer 512events Date and time stamp 8 True Partitions Separate or shared zones from other partitions Individual keypads per partition minimum 1 keypad In...

Страница 5: ... to an on site printer that will record the identity of the system description of the occurrence alarm trouble etc arm disarm by user date and time The PC4216 module provides up to 16 programmable outputs each of which may be programmed to trigger on up to 21 different options It is also used to display zones on a graphic annunciator When used in this manner all 16 outputs must be used to display ...

Страница 6: ...ition 1 Enroll every module to the system Make sure you put down the number of each module enrolled Refer to the ProgrammingManualfortherequiredprocedure When enrolling any PC4108 or PC4116 zone expander module make sure to note the zones which you assigned to the module This information is very important if it becomes necessary to Add or Delete zones to or from a Partition Zones 1 through 16 are ...

Страница 7: ...elephone cord into the RJ31 X jack If a DTS 1 is being used to monitor communicator transmissions connect it to the telephone line and place the DTS 1 in the line mode by pressing the red LINE LOCAL button Arm the panel wait for the exit delay to expire and trip a detector on an instant circuit Wait for the communication to complete Disarm the panel and check with the monitoring station to confirm...

Страница 8: ......

Страница 9: ... frequency Switched Auxiliary Supply Output Programmable for several options Battery 12 volt 4 Ah minimum rechargeable gel cell or sealed lead acidbattery Transformer 16 5 VAC 40VA Output Voltage Typically with normal AC on and a fully charged battery the output voltage will be 13 8 VDC With AC off and the battery discharging the voltage will go below 10 volts and then battery cutoff will occur pr...

Страница 10: ......

Страница 11: ...d 1 5 Amp output PC4216 Low Current Output Module 16 output low current module Up to 9 modules on system 1 module programmable for all 16 outputs 1 of 23 options for each 8 modules programmable as alarm annunciators or zone followers Four wire QUAD hook up to COMBUS Nominal current draw of 35 mA Provides Tamper and Trouble Reporting Codes Low COMBUS supervision to PC4000 Main Board PC4400 RS 232 I...

Страница 12: ......

Страница 13: ...11 ...

Страница 14: ...12 ...

Страница 15: ... is a 3A maximum switch to ground A small relay a buzzer or other DC operated device may be connected between the 12 VDC AUX positive terminal and the PGM switched negative terminal to interface with controlled devices COMBUS Terminals RED BLK YEL and GRN Connect the red wire of the COMBUS to the RED terminal the black wire to the BLK terminal the yellow wire to the YEL terminal and the green wire...

Страница 16: ......

Страница 17: ...Codes are used for arming and disarming the control panel for viewing the armed disarmed status of the partitions for programming additional security codes and for entering user functions In the disarmed state entering a Master Code will cause a nine selection menu to be displayed as follows 0 Arm Partition 1 Arm Diff Part 2 Disarm Diff Part 3 View Partitions 4 Set System Time 5 Set System Date 6 ...

Страница 18: ...ad buzzer will stop The correct security code must be entered before the allowed entry time expires To change the entry time see Installers Programming Command 8 If an alarm occurred while the panel was armed the View Memory message will be on the display with the zone name for the zone that caused the alarm The display will keep those messages on for two minutes or until the key is pressed to ret...

Страница 19: ...tored Initiating a bell comm test will check the battery voltage AC Trouble There is no audible annunciation on AC power failure The system Trouble light will come ON but the audible indication will not sound until there is a low battery condition Transmission delay can be programmed for 000 to 255 minutes Aux Supply Troub An Aux trouble is generated if the aux fuse on the main panel opens or if t...

Страница 20: ...o program additional access codes of any type The PC4000 has 128 access codes In the Installer s Programming Section these codes are divided up and assigned to partitions or are turned into System Master Codes which have control over all partitions This must be done before the user can program the access code and the code type The first code is the System Grand Master Code Only the Installer can c...

Страница 21: ...de When selected the keypad will display Enter Digits and what is currently programmed for that access code Enter in the 4 digit code Do not press or while entering the access code If you do not wish to change the code use the keys to exit When you have finished entering the code if you are programming System Master codes the keypad will return to selecting which System Master code to program If y...

Страница 22: ...Auto Arm Upon selecting the Auto Arm Control function the Auto Arm Control menu will appear on the LCD keypad 0 Auto Arm 1 Auto Arm Time Auto Arm toggles Y or N to enable or disable the Auto Arm function Auto Arm Time is the time the partition will automatically arm itself every day NOTE The Auto Arm time is a 24 hour clock and times must be entered as two digit numbers E g HH 01 02 10 11 23 24 MM...

Страница 23: ...long the outputs are activated and see Util Req Code for programming whether a utility output requires an access code to be activated Installers Programming Commands 8 Installer sCode The PC4000 is completely programmed from the keypad by using commands in the 8 section The commands are described in detail in the Programming Manual At home Arming 9 AccessCode Entering 9 before the arming code arms...

Страница 24: ......

Страница 25: ...r end into the DB 25 modular jack adapter Connect the DB 25 modular jack into the RS232 serial port of the printer See the PC4400 wiring diagram Power up the printer then the PC4000 and PC4400 If the PC4400 is already enrolled and the printer is on line the PC4400 will begin transmitting to the printer The following is a sample of a printout from the serial printer Partition Label Date Time Event ...

Страница 26: ...emory until they are ready to be printed When the printer is brought back on line the PC4400 will send the new events to the printer If 384 new events occur before the printer is brought back on line 384 events 75 of the buffer the PC4000 will send the Buf Near Full reporting code to the monitoring station See Maint Rep Codes in the Programming Flow Charts for programming the Buf Near Full reporti...

Страница 27: ...nected to the tip and ring terminals on the panel A DTS 1 must be connected to the lines and in the local mode Program the downloading access code and panel I D code Program a zone for Forced Answer See Zone Type in the Programming Guide This zone is only meant to be temporary to initiate downloading It can later be changed back to the required zone type Make sure the access code and panel I D cod...

Страница 28: ...is and shall be in lieu of any and all other warranties whether expressed or implied and of all other obligations or liabilities on the part of Digital Security Controls Ltd This warranty contains the entire warranty Digital Security Controls Ltd neither assumes nor authorizes any other person purporting to act on its behalf to modify or to change this warranty nor to assume for it any other warra...

Страница 29: ... 1993 Digital Security Controls Ltd Toronto Canada Tel 800 387 3630 FAX 905 760 3034 ...

Страница 30: ...29000223R0 ...

Страница 31: ...amming Work Sheets Used by the installer to record installer s programming and system layout Book 3 PC4000 Programming Manual Explains each section of installer s programming Book 4 PC4000 System Manual Introduces the PC4000 explains the hookup and wiring and user s programming and functions 1 PC4000 Main Control Board 1 LCD4500 Remote Keypad 1 Main Control Cabinet 1 Hardware Package EOL Resistors...

Страница 32: ...icated with the monitoringstation 10 European Pulse Dialing Page 24 An option to use American pulse dialing or European pulse dialing 11 Second Master Reporting Codes Page 27 The Second Grand Master Access Code now has its own opening and closing reporting codes when it is used to arm and disarm 12 PC4216 Zone Follower Option Page 30 The PC4216 can follow any group of 16 zones When a zone is open ...

Отзывы: