18
4204 Battery TBL...
If any PC4204 relay output
module’s battery drops below 11.3 volts, a battery
trouble is generated.
To determine which of the PC4204’s has the low battery,
check the reporting code transmitted to the monitoring
station or check the event buffer printout if there is a
printer attached, or through downloading. The battery
voltage is checked once every 4 minutes. So the battery
trouble may not restore instantly when the battery
voltage is restored.
4204 AC Trouble...
If any PC4204 relay output module
loses incoming AC power, the keypad trouble light will
indicate a 4204 AC trouble. But there will be no audible
annunciation until there is also a low battery condition.
The PC4204 AC troubles will be transmitted to the
monitoring station immediately.
4204 AUX Trouble...
If the Aux fuse on any PC4204
relay module should open or if the Aux supply is
overloaded, a 4204 Aux trouble is generated.
Alarm Memory Display
[
✱
]+[3]
Press [
✱
] then [3] to enter the alarm memory mode.
Any alarm caused during the last armed period will be
displayed. The “View Memory” message will only be
displayed when an alarm occurred during the last
armed period.
Press [#] to return to “READY”.
Sensor Reset
[
✱
]+[4]
The Main Bell, Switched Auxiliary Supply and pgm
outputs can be programmed by the installer to be a
‘Sensor Reset’. (See ‘Sensor Reset’ in the programming
guide). This option allows the user to activate these
outputs from the keypad by pressing [
✱
][4]. The
keypad will display ‘Sensor Reset in Progress..’ and a
countdown timer will show how long the sensor reset will
be active. The Sensor Reset can be from 0 to 255
seconds, which is programmed by the installer. (See
PGM Pulse Times, Utility/Sensor section in the
Programming Guide).
User Programming Commands
[
✱
]+[5]+[Master Code]
The [
✱
][5] Access Codes programming command is
used to program additional access codes of any type.
The PC4000 has 128 access codes. In the Installer’s
Programming Section, these codes are divided up and
assigned to partitions, or are turned into System Master
Codes, which have control over all partitions. This must
be done before the user can program the access code
and the code type.
The first code is the System Grand Master Code. Only
the Installer can change this code, unless the Installer
has enabled the Installer’s Programming Commands to
make the System Master Code 001 changeable.
There are 11 types of codes:
System Grand Master Code
has no limitations to its
use. It can create or delete other System Master Codes
or perform any other user feature the PC4000 user is
capable of doing.
System Master Codes
can do anything on the system.
They can be used to bypass, view memory and view
trouble, etc. They may be used to create or delete any
type of code except for System Master Codes.
Partition Master Codes
has unlimited access to their
own partition. These types of codes can create, delete or
alter any code type in their partition other than System
Masters. They can only assign users to their own
partition. They cannot program the group mask, to allow
access codes to be used in other partitions.
Arm/Disarm/Bypass Access Code
may arm, disarm or
bypass on the partition to which it has been assigned.
Arm / Disarm Access Code
can only be used to arm
or disarm the partition to which it has been assigned.
Arm Only Access Code
can only arm the partition to
which it has been assigned.
Door Strike Code
can only activate [
✱
][7] utility output
on the partition it belongs to if the partition is disarmed.
Log Only Code
will only put a record on to the event
buffer.
Arm / Disarm /OTU Code
may arm and disarm the
partition to which it has been assigned. The code is
erased when used to arm.
Arm Only OTU Code
may only arm a partition. The
code is erased when used to arm.
Door Strike OTU Code
is erased after used.
NOTE: OTU stands for One Time Use.
Содержание SYSTEM MASTER PC4000
Страница 1: ...SYSTEM MANUAL PC4OOO Book 4 Jan 11 1993 Software Version 1 3 ...
Страница 8: ......
Страница 10: ......
Страница 12: ......
Страница 13: ...11 ...
Страница 14: ...12 ...
Страница 16: ......
Страница 24: ......
Страница 29: ... 1993 Digital Security Controls Ltd Toronto Canada Tel 800 387 3630 FAX 905 760 3034 ...
Страница 30: ...29000223R0 ...