background image

2.

The HSPA3G Cellular path isimmune to conducted and radiated RF fields
with levelsup to 10V/mastested per EN50130- 4 Standard.

3.

The TL2803G(R)E-EU/3G2080(R)E-EU/TL280(R)Emodule conforms
with radiated emissionslevelsfor ClassBequipment asper standards
EN61000- 6-3/EN55022/CISPR22.

4.

The TL2803G(R)E-EU/3G2080(R)E-EU/TL280(R)Emodule uses
AES128 encryption and heartbeat supervision for HSPA3G Cellular com-
munication pathsand it meetssecuritylevelsS2 asper EN50136-2:2013.
It also usesauthentication for each message exchanged with the com-
patible receiver equipment at ARC and it meetslevelI2 for information
security.

5.

The 3G2080(R)E-EU module hasonlyone communication path:
HSPA3G Cellular communication path using 900/1800/2100MHzPublic
Cellular Network. The HSPA3G Cellular communication path that can be
used in a standalone mode in conjunction with a DSC alarmsystem(com-
patible DSC alarmcontrolpanelmodels: HS2128/064/032/016). The sup-
ported ATSconfiguration is: customcategoryC.

6.

The TL280(R)Emodule hasonlyone communication path: Ethernet com-
munication path using Internet. The communication path that can be used
in a standalone mode in conjunction with a DSC alarmsystem(compatible
DSC alarmcontrolpanelmodels: HS2128/064/032/016). The supported
ATSconfiguration is: customcategoryC.

7.

The TL2803G(R)E-EU module hastwo communication paths: HSPA3G
Cellular communication path using 900/1800/2100MHzPublicCellular Net-
workand Ethernet communication path using Internet. The com-
munication pathscan be used in a standalone mode in conjunction with a
DSC alarmsystem(compatible DSC alarmcontrolpanelmodels:
HS2128/064/032/016). The supported ATSconfiguration is: customcat-
egoryC.

8.

TL2803G(R)E-EU/3G2080(R)E-EU/TL280(R)Ehasbeen tested for com-
pliance in conjunction with the following applicable standards: EN50136-
1:2012, EN50136- 2:2013, EN50131-10:2014, ATSconfiguration: C.

For EN50131- 1:2006/A1:2009 compliant installations, the following programming
optionsshallbe set asdescribed.
Supervision Heartbeat: shallbe set to 180 seconds

NOTE:

The compatible receiver at ARC location shallhave supervision window pro-

grammed for 180 seconds. TL2803G (R)E-EU/3G2080 (R)E- EU/TL280(R) E has
been certified by TELEFICATION in accordance with EN50131- 1:2006/A1:2009,
EN50131-10:2014 requirementsfor Grade 2, ClassII and EN50136-2:2013 Con-
figuration: C

ATS Custom Category C

Level

EN50136-1:2012 AnnexD Table D.1

D3

EN50136-1:2012 AnnexD Table D.2

M3

EN50136-1:2012 AnnexD Table D.3

T4

EN50136-1:2012 AnnexD Table D.4

A4 (Depending on cellular carrier used)

EN50136-1:2012 AnnexD Table D.5

S2

(use

AES-

128

and

authentication/sequentialinformation in
each message transmitted to the SG
receiver)

EN50136-1:2012 AnnexD Table D.6

I2 (use AES-128 encryption)

EN50136-1:2012 Table 1

Use single communication path for
models 3G2080 (R) E- EU

(cellular

network), TL280 (R) E (Ethernet port)
and two communication pathsfor model
TL2803G(R)E-EU (cell/Ethernet).

EN50136-1:2012 Table 4

ATSfailure reported to ARC

EN50136-1:2012 Table 5

ATS failure reported to AS (DSC
compatible

control

panel

HS2128/HS2064/HS2032/HS2016)

EN50136-1:2012 Table 6

There is no recording of availability
failure

EN50136-2:2013 Table 1

No logging function provided

EN50136-2:2013 Table 2

No memory provided for logging
function

EN50136-2:2013 Table 3

ATSfailure reported to ARC

SIMPLIFIED EU DECLARATION OF CONFORMITY

Hereby, Tyco SafetyProductsCanada Ltd declaresthat the radio equipment type
isin compliance with Directive 2014/53/EU. The full text of the EU declarations of
conformityfor the models mentioned below are available at the following internet
addresses:
TL2803G(R)E-EU - http://dsc.com/pdf/1605003
3G2080(R)E- EU - http://dsc.com/pdf/1605004

Frequency Band

Maximum Power

EGSM900 890.0MHz- 914.8MHz

Class4 (2W) @ 900MHz, GSM

EGSM900 880.2MHz-889.8MHz

Class1(1W) @ 1800MHz, GSM

DCS1800 1710.2MHz-1784.8MHz

ClassE2 (0.5W) @ 900MHz, EDGE

WCDMA

(Band

VIII)

882.4MHz

-

912.6MHz

ClassE2 (0.4W) @ 1800MHz, EDGE

WCDMA2100 (Band I) 1922.4MHz -
1977.6MHz

Class 3 (0.25W) @ 900/2100MHz,
WCDMA

Onlymodels TL2803GRE-EU, TL2803GE- EU, 3G2080RE-EU, 3G2080E-EU are
CEcompliant.
European single point of contact: Tyco Safety Products, Voltaweg 20, 6101 XK
Echt, Netherlands

UL/ULC Installation Requirements

NOTE

: For equipment used at the protected premises and intended to facilitate IP

communications (hubs, routers, NIDs, Digital Subscriber Line (DSL), cable
modems), 24 hour backup power is required. Where such cannot be facilitated, a
secondary(back-up) communication channelisrequired.

Domain Name Service (DNS) programming is not permitted in UL1610

listed systems.

Technical Specifications

The input voltage to the Communicator can be drawn from the Underwriters Lab-
oratories/UnderwritersLaboratoriesCanada (UL/ULC) listed controlpanel.

Notes for using Private, Corporate, and High Speed Data Networks:

Networkaccessand domain accesspoliciesshallbe set to restrict unauthorized net-
workaccess, and spoofing or Denial of Service (DoS) attacks. Select an Internet
Service Provider (ISP) that hasredundant servers/systems, back-up power, routers
with firewalls enabled, and methods to identify and protect against DoS attacks
(e.g., via spoofing).

Notes for using Public Switched and Cellular Data Networks:

Communication channelsshallbe facilitated such that the communicator will restrict
unauthorized access, which could otherwise compromise security. The com-
municator shallbe located in a secured area.
• For

ULC Residential Fire and Burglary

applications the

TL2803G (R)

E/3G2080(R)E/TL280(R)E/LE2080(R)/TL280LE(R)

can be used asprimary com-

munication channelvia either cellular or Ethernet or asa back-up in conjunction with
the Digital Alarm Communicator Transmitter (DACT). Test transmission every 24
hoursshallbe enabled on each channel.
• For

ULC Commercial Fire and Burglary

applications the

TL2803G (R)

E/3G2080(R) E/TL280(R) E/LE2080 (R)/TL280LE(R)

can be used as a passive

communication module with the following securitylevels:

l

P1 (each channelcellular or Ethernet isindependent)

l

P2 (cellular and Ethernet in back-up configuration, panelsection [851][005]
toggle option [5] OFF).

l

P3 (cellular and Ethernet in redundant configuration, panelsection [851]
[005] toggle option [5] ON).

The communicator can also be used as an active communication system with the
securitylevelsA1-A4 (each channelcellular or Ethernet independent or together in
a back-up/redundant configuration). For active line security systems AES128 bit
encryption shallbe enabled (at the monitoring station receiver) and the supervision
heartbeat rate shallbe set as90 seconds (panelsection [851][004] = 005A/90).
The supervision window at the SignalReceiver Center (SRC)'sreceiver shallbe pro-
grammed asmaximumof 180 (00B4/180) seconds.

NOTE

: For ULC commercial fire passive communication, encryption shall be

enabled,
• For

UL Residential Fire and Burglary

applications the

TL2803G (R)

E/3G2080R/TL280(R)E/LE2080(R)/TL280LE(R)

can be used asthe primarycom-

munication channel via either cellular or Ethernet, or asa back- up in conjunction
with the DACT (30 daytest transmission isrequired on each channel).
• For

UL Commercial Burglary

applications the

TL2803G(R) E/ 3G2080R /

TL280(R)E / LE2080(R) / TL280LE(R)

can be used asdual signalling line com-

munication system (cellular and Ethernet channels used in redundant con-
figuration), standard line securityand asencrypted line security.
• The supervision heartbeat shall be enabled (panel section [851][005] toggle
option [1] (Ethernet) and/or toggle option [2] (cellular) shallbe ON), toggle option
[3] (supervision type) shallbe ON and the supervision heartbeat rate shallbe selec-
ted as135 (0087/135) seconds. Option [004] = 0087. The supervision window at
the supervising station shall be maximum200 (00C8/200) seconds. For encrypted
line security systemsthe encryption AES128 bit shall be enabled at the monitoring
station receiver.
• For

UL Commercial Burglary

installations, the

TL2803G (R) E/3G2080 (R)

E/TL280(R)E/LE2080 (R)/TL280LE(R)

is listed asa primary (sole) communication

means(heartbeat must be enabled) or for supplementary (back- up) use in con-
junction with a Plain Old Telephone Service (POTS) line dialer. When the heartbeat
transmission over the Ethernet or cellular networkis enabled, using the TL2803G
(R) E/3G2080 (R) E/TL280 (R) E with a compatible control unit listed for stand-
ard/encrypted line security, it can provide line securityfor the alarmsystemover the
primaryline.
•The

TL2803G(R)E/3G2080(R)E/TL280(R)E/LE2080(R)/TL280LE(R)

isalso suit-

able to be used with a compatible control unit listed for dual line security trans-
mission when used in conjunction with a DACT or a Public Switched Data Network
(PSDN) transmitter, where the PSDN provides the line security and is the primary
line. In this mode, alarmsignals are required to be sent simultaneously over both
communication methods.

19

Содержание PowerSeries Neo 3G2080RE

Страница 1: ...SPA Cellular Alarm Communicator TL2803G R E Internet and HSPA Dual Path Alarm Communicator TL280 R E Internet Alarm Communicator Installation Guide 5 x Warning This manual contains information on limi...

Страница 2: ...e to protectthe occupantsortheirbelongings Motion Detectors Motion detectors can only detectmotion within the designated areas asshown in their respective installation instructions They cannot discrim...

Страница 3: ...llowing bands 900 2100MHz Models TL2803GRE AU TL2803GE AU TL280RE AU TL280E AU 3G2080E AU and 3G2080RE AU 850 2100MHz operation are for Australia New Zealand Brazil and cover the following bands 850 2...

Страница 4: ...nd HS2128 panels l 3G2080 R E HSPA 3G GPRS only l TL2803G R E Ethernet Internet HSPA 3G GPRS dual path l TL280 R E Ethernet Internet only l LE2080 R LTE 4G HSPA 3G only l TL280LE R Ethernet Internet L...

Страница 5: ...cation paths if redundant con figuration is desired l 382 enable option 5 YES to enable Alternate communicator l 384 enable the desired back up configuration receiver 2 back up for receiver 1 or recei...

Страница 6: ...ervice persons only service person is defined as a person having the appro priate technical training and experience necessary to be aware ofhazards to which thatperson may be exposed to in per forming...

Страница 7: ...lation manual for the 3rd party device for wiring instructions Installing Communicator in Panel Installing the Communicator with HS20XX Panels NOTE Before installing the communicator or inserting remo...

Страница 8: ...outside the panel Tighten the assembly by hand only finger tight only do not over tighten the antenna assembly e Locate the screw hole on the right side wall of the panel See Figure 2 screw Line up t...

Страница 9: ...LINK_2 COM TL2803G R E 3G2080 R E TL280 R E TL280LE R LE2080 R ACAC Z1 COM Z2 Z3 COM Z4 Z5 COM Z6 Z7 COM Z8 AUX BELL PGM1 PGM3 RING T 1 HS2016 2032 2064 2128 3G LTE Radio UA621 L o c k 1 RJ 45 GRN YEL...

Страница 10: ...ocedure if the radio signal strength is too low 1 Confirm that the yellow LED on the communicator is not flashing A flashing yellow LED indicates trouble on the com municator See Table 7 to troublesho...

Страница 11: ...d when toggle is OFF e g toggle options displays 3 6 Options 3 and 6 are ON all others are OFF Pressing keys 1 through 8 will alternately turn the toggle ON and OFF l HEX DecimalData Values that are p...

Страница 12: ...to the central station receiver The reporting codes are ET0001 for trouble and ER0001 for restore The panel absenteventalways uses the primary receiver accountcode when communicating to the central s...

Страница 13: ...Connection Status LED TL2803G R E TL280LE R BLINKING Indicates communications in progress l Once quickly for outgoing Ethernet transmission l Twice quickly to indicate incoming Ethernet ACK NACK OFF...

Страница 14: ...or to the factory settings by installing a hardware jumper Perform the following steps to resetthe communicator NOTE A jumper is required on AUDIO DEFAULT pins 4 and 5 to resetthe hardware values 1 Re...

Страница 15: ...inserted into the SIM card holder l Ensure the SIM card has been activated could take up to 24 hrs after install l If this trouble persists relocate the panel and communicator or install an external...

Страница 16: ...system account code or sections 101 111 201 and 211 receiver account code have not been programmed Ensure that a valid account code has been entered in these sections All LEDs flashing together N A Bo...

Страница 17: ...ity Controls Digital Security Controls neither assumes responsibility for nor authorizes any other person purporting to act on its behalf to modify or to change this warranty nor to assume for it any...

Страница 18: ...on a regular basis However despite frequent testing and due to but not limited to criminal tam pering orelectrical disruption it ispossible forthis SOFTWAREPRODUCT to fail to performasexpected Regulat...

Страница 19: ...ended to facilitate IP communications hubs routers NIDs Digital Subscriber Line DSL cable modems 24 hourbackup poweris required Where such cannot be facilitated a secondary back up communication chann...

Страница 20: ...and Tyco will aggressivelyenforce its intellectualpropertyrights to the fullestextent ofthe law including pursuitof criminalprosecution wherever neces sary Alltrademarksnotowned byTyco are the propert...

Страница 21: ...alarmes Cellulaire HSPA TL2803G R E Communicateur d alarmes double voie Internet et LTE HSPA TL280 R E Communicateur d alarmes sur Internet Guide d installation 5 X Avertissement Le pr sent manuel con...

Страница 22: ...t le mouvement que dans les zones d sign es conform ment aux instructions d installation Ils ne peuvent pas dis tinguerlesintrusdesoccupants Lesd tecteursde mouvementne fournissentpas de protection vo...

Страница 23: ...U 3G2080RE EU 3G2080E EU fonc tionnement 900 2 100 MHz et 3G2080E EU sont destin s au march europ en et couvrent les bandes suivantes 900 2 100 MHz Les mod les TL2803GRE AU TL2803GE AU TL280RE AU TL28...

Страница 24: ...meilleur emplacement pour la r ception radio au moins un t moin LED vert allum Les kits d antenne optionnels GS 15ANTQ GS 25ANTQ GS 50ANTQ sont disponibles aupr s de DSC pour am liorer la force du si...

Страница 25: ...pour les voies de communication disponibles l 851 124 125 et 224 225 doivent tre programm s avec l heure laquelle la transmission de test sera effectu e et un d lai de 1 440 minutes 24 h pour le cycle...

Страница 26: ...et 2 Lorsque le cryptage estactiv le central de t l surveillance configure l appareil pour crypter les com munications lors de la prochaine fois que le communicateur esten communication avec ce r cept...

Страница 27: ...SIM pour le faire glisser en position VERROUILL E dans le sens indiqu par la fl che sur le porte carte 7 Rebranchez la batterie de secours et la ligne t l phonique r tablissez l alimentation de la cen...

Страница 28: ...ndelle en nylon avec bague rondelle plate paisse sur la partie filet e du c ble d antenne Ins rez la partie filet e par le trou d fon able de supportd antenne situ en haut droite de la centrale d Plac...

Страница 29: ...t e 3 Pour brancher lectriquement le communicateur la centrale effectuez les tapes suivantes Voir Figure 3 a d branchez les connexions de l alimentation secteur et de la batterie de la centrale puis d...

Страница 30: ...rs antenne externe 2 AUDIO PAR D FAUT Cavalier sur les broches 4 et 5 pour r initialiser 3 Lien r seau jaune 4 Depuis le NID utilisez exclusivement un c ble CAT5 supervis Longueur de c ble de 100 m ma...

Страница 31: ...bl me sur le com municateur et que les t moins LED verts ne sont pas valides pour le test d emplacement du communicateur Avant de continuer corrigez le probl me signal par les clignotements du t moin...

Страница 32: ...externe 4 D placez l extension d antenne diff rents emplacements en observant les deux t moins LED verts sur la centrale a Poursuivez le repositionnement de l extension d antenne jusqu recevoir une f...

Страница 33: ...pour v rifier les op rations d activation de programmation du communicateur Toutes les options du communicateur doivent tre programm es via le service C24 Communications saufles options Ether netsuiv...

Страница 34: ...i le bit8 de l option 851 005 est teint une valeur CSQ 4 ne d clenchera pas le probl me cellulaire Probl me Ethernet 6 clignotements Ce probl me est signal lorsque la liaison Ethernet entre l metteur...

Страница 35: ...l appareil n arrive pas obtenir une adresse IP du r seau cellulaire ou la connexion cellulaire a t r initialis e T moin LED vert 1 T moin LED vert 2 et T moin LED jaune Force du signal REMARQUE Si le...

Страница 36: ...jour du communicateur Retour aux valeurs d usine par d faut R initialisez les options de programmation du communicateur aux valeurs d usine en installant le cavalier mat riel Pro c dez comme suitpour...

Страница 37: ...de supervision de la centrale l V rifiez que l option 5 de la section 382 est bien Allum Activer le communicateur alternatif l V rifiez que le c ble PC LINK reliant la Centrale et le communicateur est...

Страница 38: ...rrectement avec le r cepteur l Si le probl me persiste contactez le central de t l surveillance T moin LED jaune flashe neuf fois 09 Probl me EDC l L appareil a puis toutes les tentatives de communica...

Страница 39: ...une r clamation par ou contre DSC les limitations et les exon rations contenues dans la pr sente garantie respecteront la loi Certains tatsne permettent pas l exon ration ou la limitation des dommage...

Страница 40: ...N DE GARANTIES CETTE GARANTIE CONTIENT L ENTI RE GARANTIE ET REMPLACE TOUTES LES AUTRES GARANTIES QU ELLES SOIENT EXPLICITES OU IMPLICITES NOTAMMENT TOUTESLESGARANTIESIMPLICITESDEMARCHANDISEOU APTITUD...

Страница 41: ...gorie 2 classe IIetEN50136 2 2013 configuration C Cat gorie C personnalis e ATS Niveau EN50136 1 2012 annexe D tableau D 1 D3 EN50136 1 2012 annexe D tableau D 2 M3 EN50136 1 2012 annexe D tableau D 3...

Страница 42: ...te avecs curit de ligne standard ets curit de ligne crypt e Les battementsde c ur de supervision doivent tre activ s section 851 005 de la centrale option de bascule 1 Ethernet et ou option de bascule...

Страница 43: ......

Страница 44: ...syst mes certifi s NFA2P utiliser uniquementune longueur de c ble Ethernetde 3m 2018 Produits de s curit Tyco Tous droits r serv s Supporttechnique 1 800 387 3630 Canada et tats Unis ou 905 760 3000...

Отзывы: