background image

D-306633 PGx914 Installation Instructions

1

PG4914 / PG8914 / PG9914

PowerG Wireless, PIR/Pet Immune Motion Detector Installation
Instructions

The PGx914 (pet immune) is a microprocessor-controlled wireless digital PIR

detector supported by DSC alarm systems using PowerG two-way

communication protocol.

The detector's features are as follows:

l

Fresnel and cylindrical lenses with uniform detection sensitivity

throughout its operating range, up to 12 meters (39 ft).

l

Target Specific Imaging™ (TSI) technology is used for distinction

between humans and pets weighing up to 38 kg (85lb).

l

The advanced True Motion Recognition™ algorithm (patented)

distinguishes between the true motion of an intruder and any other

disturbances which may cause false alarms.

l

No vertical adjustment is needed.

l

Motion event counter determines whether 1 or 2 consecutive

motion events trigger an alarm.

l

Very low current consumption.

l

Microprocessor-controlled temperature compensation. Sealed black

chamber provides white light protection.

l

Front and back tamper protection.

l

The device supports temperature and light level reports to

compatible alarm systems that support temperature and light

sensors.

For UL installations: The detector is for use with UL listed control units
only. Pet immunity has not been evaluated by UL.

A. Enroll button

B. Light sensor

C. LEDs

D. Tamper switch

E. PIR sensor

Internal View

1. INSTALLATION

General Guidance

1. Keep away from heat

sources.
2. Do not expose to air

drafts.
3. Do not install outdoors.
4. Avoid direct sunshine.
5. Do not install near high-

voltage electrical lines.
6. Do not install behind

partitions.
7. Mount on a solid stable

surface.

Warning!

Do not partially or

completely obscure the
detector's field of view.

Installation

 

Procedure

A: Surface mount

B: Corner mount, B1 or B2

C: Back tamper

D: Cover
E: Base
F: Press in point

1.

Mount the bracket on the wall.

2.

Press in the point marked "F" in the drawing and

separate the cover from the base.

3.

Insert the battery while observing polarity-OR- If battery

is already installed, remove the activation strip that

protrudes from the front of the detector.

4.

Return the cover to the base until a click is heard (the

snap is closed).

5.

Secure the detector with the screw.

6.

Align the detector with the bracket.

7.

Slide the detector upward until a click is heard.

Note:

The detector transmits a low battery signal upon detection of low

voltage. It is recommended to wait about 1 minute after battery removal,
before inserting the new battery.
PGx914 shall be installed in accordance with the Standard for Installation and
Classification of Burglar and Holdup Alarm Systems, UL 681.

Caution!

Risk of explosion if battery is replaced by an incorrect type. Dispose

of used battery according to the manufacturer's instructions.

Removing the Pet Mask

Remove the plastic pet mask if you do not require pet immunity.

1. Place your thumb at the base of the Pet Mask.
2. Place your fingers at the top of the Pet Mask.
3. Lift the Pet Mask to remove.

Disassembly from Bracket

1. Release screw.
2. Separate the cover from the base.
3. Remove battery.
4. Press on the stopper snap to release the base from the bracket.
5. Slide the base downward to remove.

Enrollment

See the alarm systems Installation Guide and follow the enrollment

procedure.
A general description of the procedure is provided in the following flow chart.

Step Procedure

1

See the Installation Manual for the alarm system that the device is

being enrolled on, to ensure that the proper steps are used.

2

Enter the Device Enrollment option through the specified method

and select the appropriate option to add a new device.

3

Enroll the device by either holding the enroll button until the

enrollment is detected, or by entering the Device ID.

4

Select the desired Zone Number.

5

Configure any device parameters that are required.

6

Mount and test the detector. See section 3 for information on testing

the device. In addition, see the alarm systems Installation Manual

that the device is enrolled on for other test procedures that are

required.

Note:

If the detector is already enrolled, you can configure the detector parameters

by programming the system, see the alarm systems Installation Manual for

more information about device parameters.

Temperature Display

For instructions on displaying the temperature of zones on the control panel

as measured by PGx914 detectors, see the alarm systems Installation Manual

for details.

2. Configuring the Detector Parameters

Enter the

DEVICE SETTINGS

menu and follow the configuration instructions

for the PGx914 detector as described in the following table.

Option

Configuring Instructions

Alarm

LED

Define whether or not the alarm LED indication will be activated.

Optional settings: LED ON (default) and LED OFF.

Event

Counter

Define whether an alarm will be activated upon continued

motion (low sensitivity) or upon a single alarm event (high

sensitivity). Optional settings: LOW sensitivity (default) and HIGH

sensitivity.

High

Traffic

Shutdown

Define whether or not the sensor is active when the system is

disarmed. Optional settings: NOT Active while disarmed

(default), - no delay, 5s delay, 15s delay, 30s delay, 1m delay,

2m delay, 5m delay, 10m delay, 20m delay and 60m delay.

3. LOCAL DIAGNOSTICS TEST

Note: Run a diagnostic test at least once a week to ensure that the detector
is working correctly.

1.

Separate the base from the cover .

2.

Replace the cover to return the tamper switch to its normal

(undisturbed) position, and then secure the front cover to the base with

the case closure screw.

3.

The PGx914 detector will enter a 2 min. stability period. During this time

the red LED blinks.

4.

Walk-test the coverage area.Walk across the far end of the coverage

pattern in both directions. The red LED lights each time your motion is

detected followed by 3 LED

 

blinks.

Important!

Instruct the user to walk test at least once a week to verify

proper functioning of the detector.

The following table outlines received signal strength indication:

LED response

Reception

Green LED blinks Strong
Orange LED blinks Good
Red LED blinks

Poor

No blinks

No communication

Important!

Reliable reception must be assured. Therefore,

poor

signal

strength is not acceptable. If you receive a

poor

signal from the device, re-

locate it and re-test until a

good

or

strong

signal strength is received.

For UL/ULC installations, only

STRONG

signal level are acceptable.

Содержание PG4914

Страница 1: ...Press on the stopper snap to release the base from the bracket 5 Slide the base downward to remove Enrollment See the alarm systems Installation Guide and follow the enrollment procedure A general description of the procedure is provided in the following flow chart Step Procedure 1 See the Installation Manual for the alarm system that the device is being enrolled on to ensure that the proper steps...

Страница 2: ...e lens tampering with the optical system decreased sensitivity in ambient temperatures close to that of the human body and unexpected failure of a component part The above list includes the most common reasons for failure to detect intrusion but is by no means comprehensive It is recommended that the detector and the entire alarm system be checked weekly to ensure proper performance An alarm syste...

Страница 3: ...le socle du support 5 Faites coulisser le socle vers le bas pour le retirer Enregistrement Consultez le Manuel d installation des systèmes d alarme et suivez la procédure d enregistrement Une description générale de la procédure est indiquée dans le tableau suivant Étape Procédure 1 Consultez le Manuel d installation du système d alarme dans lequel l appareil est enregistré afin de suivre la procé...

Страница 4: ...r à la vérification hebdomadaire du détecteur et du système d alarme dans son ensemble afin de s assurer de son bon fonctionnement Un système d alarme ne doit en aucun cas se substituer à une assurance Les propriétaires de biens immobiliers ou locataires doivent faire preuve de prudence et continuer d assurer leur vie et leurs biens même s ils sont protégés par un système d alarme CARACTÉRISTIQUES...

Страница 5: ...os 2 Acceda a la opción de memorización de dispositivo a través del método especificado y seleccione la opción apropiada para agregar un nuevo dispositivo 3 Registre el dispositivo sosteniendo el botón de memorizar hasta que se detecte la inscripción o introduzca el ID de dispositivo 4 Seleccione el número de zona deseado 5 Configure los parámetros del dispositivo que sean necesarios 6 Montar y pr...

Страница 6: ...sistema de alarma ESPECIFICACIONES Tipo de detector Sensor piroeléctrico de bajo ruido de elemento doble Datos de lentes La lente tipo Fresnel y la de tipo cilindro con atenuación óptica máscara de mascota en la parte del patrón inferior de la lente Cantidad de haces o cortinas 27 lentes de Fresnel de lejos 18 medias cilíndricas y 10 de cerca no cilíndricas Figura 12 Prueba de recorrido de patrón ...

Страница 7: ...ir que os passos apropriados sejam usados 2 Insira a opção Inscrição de Dispositivos através do método especificado e selecione a opção apropriada para adicionar um novo dispositivo 3 Inscreva o dispositivo segurando o botão de registro até que a inscrição seja detectada ou digitando o ID do dispositivo 4 Selecione o Número de Zona desejado 5 Configure os parâmetros necessários do dispositivo 6 Mo...

Страница 8: ...idos por um sistema de alarme ESPECIFICAÇÕES Tipo de detector Sensor piroelétrico de duplo elemento de baixo ruído Dados da lente Lentes do tipo Fresnel e cilíndricas com atenuação ótica máscara de PET na parte inferior padrão das lentes Número de feixes cortinas 27 Fresnel longe 18 cilíndricos médio e 10 cilíndricos perto Figura 12 Teste de caminhada do Padrão de abrangência 12 x 12 m 39 x 39 pés...

Отзывы: