6.1 Trouble Conditions
The control panel always watches for possible trouble conditions. If a trouble
condition occurs, the keypad “Trouble” light will turn on and the keypad will
beep. Press [
✱
][2] to display the trouble conditions.
The following trouble conditions apply to the PC5132-RS and/or any enrolled
devices. For a description of all troubles, please see your system
Installation
Manual.
• General System Tamper
• Zone Fault
• General System Supervisory
• Device Low Battery
• Zone Tamper
Wireless Zone Low Battery Transmission
Within the supervisory transmission, the device will indicate the status of the
battery. If a battery is low, the system will indicate a Device Low Battery trouble.
NOTE: Since the WLS908 does not send supervisory transmissions, a low bat-
tery on this device will not cause a Device Low Battery trouble. The user should
be instructed to test this device every week. See section 5.4 for testing instruc-
tions.
The system will delay reporting the event to the central station for the number
of days programmed for
Zone Low Battery Transmission Delay
in section
[370]. This will prevent unnecessary reporting of the event if the user has been
instructed on how to replace batteries.
Replacing Batteries in Wireless Devices
1
Remove the cover of the device from its back plate. This creates a
tamper condition on the zone.
2
Refer to the battery installation instructions on the installation sheet of
each component. Be sure to
note
the proper orientation of the batteries
as you install them.
3
When the fresh batteries are in place, re-attach the cover to the back
plate. The tamper is restored and the zone sends a battery trouble
restoral signal to the PC5132-RS. The battery trouble is now clear and the
device should function normally.
NOTE: When batteries in one device need to be replaced, the batteries in all
devices should be replaced at the same time.
S E C T I O N 6