10
3.5 Enrolling & Programming Handheld Keypads (WLS910)
For handheld keypads to work on the system, you need to enroll them and then
program the function buttons. You can enroll up to 4 handheld keypads on the
system.
Enroll Handheld Keypads
1. At a system keypad, enter [
✱
][8][Installer’s code] to go to the Installer’s
Programming section.
2. Enter programming section [804].
3. Enter a 2-digit number (33-36) to assign the handheld keypad a slot.
These numbers correspond to handheld keypad numbers 1-4.
4. Enter the keypad’s ESN. The entry
must be six digits. If an older keypad
with a 5-digit ESN is being enrolled, add the digit [0] to the beginning of
the ESN. (E.g. ESN=21234, enter 021234)
5. The keypad is now enrolled on the system. Record the serial number and
the assigned slot number in the programming worksheets in the back of
this manual.
6. Repeat steps 3 - 5 until all handheld keypads have been enrolled.
7.
(PC5010 and PC5015 only)
By default, all handheld keypads are
assigned to Partition 1. To assign a keypad to Partition 2, enable the
appropriate options in programming section [90].
NOTE: A handheld keypad can only be assigned to one partition.
8. To exit press [#].
Program the WLS910 Function Buttons
WLS910 handheld keypads have four programmable function buttons. You
must program a set of four functions for the function buttons to work.
For systems not using partitions:
program the function buttons in section
[57]. All handheld keypad buttons will have the same four functions.
For systems using 2 partitions (PC5010 and PC5015 only):
all handheld
keypads assigned to Partition 1 will have the four functions programmed in
section [57]. All handheld keypads assigned to Partition 2 will have the four
functions programmed in section [58]. For example, if function button 1 in
Section [57] is programmed for Stay arming, then pressing the first button on
handheld keypads assigned to Partition 1 will Stay arm Partition 1.
1. At a system keypad, enter [
✱
][8][Installer’s code] to go to the Installer’s
Programming section.
2. Enter programming section [804].
3. Enter programming section [57] for partition 1 function buttons, or [58] for
partition 2 function buttons.
4. For each of the 4 function buttons, enter the 2-digit number of the
function you want to select. See the programming worksheets for a list of
function button options.
5. Record your programming choices in the worksheets in the back of the
manual.
6. To exit press [#].
W I R E L E S S D E V I C E S