16
5.2 Test WLS908, WLS909 and WLS910 Reception
The panic pendant (WLS908), wireless key (WLS909) and handheld keypad
(WLS910) cannot be tested using the module placement test described above.
To ensure that the PC5132-RS is receiving transmissions from these devices,
conduct the following tests:
WLS908:
Activate the Panic alarm at several different points in the
installation.
NOTE: The PC5132-RS v2.0 and lower will activate an alarm when the “test”
button is pressed on the WLS908.
WLS909:
Use the function keys to arm and disarm the system at several
different points in the installation.
WLS910:
Use the keypad to arm and disarm the system from several
different points in the installation.
If these devices do not operate from all points in the installation, you will need
to move the PC5132-RS receiver. Moving the PC5132-RS higher will usually
improve the reception.
If you move the PC5132-RS, repeat the tests described in sections 5.1 and 5.2
on all the wireless devices. Continue to test the devices until you have found
satisfactory locations for the PC5132-RS and the WLS904, WLS905, WLS906
and WLS907 devices, and there is good reception between the PC5132-RS and
the WLS908, WLS909 and WLS910 devices.
5.3 Mount the PC5132-RS and Wireless Devices
Do not permanently mount the PC5132-RS until you have tested reception with
all the wireless devices (see sections 5.1 and 5.2).
Once you have a good location, mount the PC5132-RS:
1. Remove the four screws that attach the PC5132-RS to the plastic cabinet.
2. Pull the Keybus wires through the hole at the back of the cabinet.
3. Mount the cabinet securely to the wall.
4. Reattach the PC5132-RS to the mounted cabinet using the four mounting
screws.
Mount the WLS904, WLS905, WLS906 and WLS907 Devices
If you have conducted the placement test described in section 5.1 and got 3
“Good” or “Fair” results in a row for each device, you can mount the wireless
devices. See the Installation sheet for each device for mounting instructions.
5.4 Battery Test for WLS908 Panic Pendants
You cannot test Panic Pendant batteries using the methods described in
sections 5.1 and 5.2. You must program panic pendant zones before you can
test the panic pendants.
NOTE: The PC5132-RS v2.0 and lower will activate an alarm when the “test”
button is pressed on the WLS908.
T E S T I N G & M O U N T I N G