hank you for purchasing the PC5132-RS Wireless Receiver. This product

is the result of several years of development and will allow you to connect
up to 8 wireless detection devices to the PC585, PC1565, PC5008 and

up to 32 detection devices to the PC5010 and PC5015.

The PC5132-RS uses 900 MHz, spread spectrum technology, which provides
several advantages:

• supervisory transmissions are sent every 12 minutes, as opposed to every

50-60 minutes

• programmable supervisory window can be as little as 1 hour, or as long as

24 hours

• devices use standard alkaline batteries as opposed to specialized

batteries

• orthogonal antenna arrangement for better RF reception

Version 3.0 of this product introduces 

two new features

:

6 digit serial numbers for all wireless devices:

  These new serial

numbers include hexadecimal digits.  

Please read  Section 3.1 “A note on

Electronic Serial Numbers (ESN)” for more information on enrolling older 5-
digit and newer 6-digit devices.

Identification of Wireless Keys (WLS909):

 Wireless keys 1 to 16 can now

be identified as access codes 17 to 32 (respectively) for identified
openings/closings and command output activation.  This feature is only
supported on the following control panels:  PC5010 v2.1, PC5015 v2.2,
PC5008 v2.1, PC1565 v2.1 and PC585 v2.1 or higher. 

For more information

regarding this feature, see Section 3.4 “Identified Wireless Keys.”

We are confident you will find the PC5132-RS Wireless Receiver a unique and
useful control panel enhancement.

Содержание PC5008

Страница 1: ...or better RF reception Version 3 0 of this product introduces two new features 6 digit serial numbers for all wireless devices These new serial numbers include hexadecimal digits Please read Section 3...

Страница 2: ...and wireless devices follow these steps 1 Temporarily mount and wire the PC5132 RS module see Section 2 2 Enroll and program wireless devices using zones see Section 3 3 Enroll and program wireless k...

Страница 3: ...WLS904 Motion Detector WLS906 Smoke Detector WLS905 and WLS907 Universal Transmitters WLS908 Panic Pendant WLS909 Wireless Key WLS910 Handheld Keypad 1 4 Batteries The wireless devices are designed to...

Страница 4: ...s and heating and air conditioning units large metal objects like heating ducts and plumbing which may shield the antenna Make sure that electrical wires will not run over the antenna s of the module...

Страница 5: ...anel according to the following diagram After you have completed the wiring re connect the power to the security system Once power is restored the system will automatically detect the presence of the...

Страница 6: ...decimal digits For instructions on programming hexadecimal numbers see your system Installation Manual section 4 How to Program When connecting the PC5132 RS to a PC5010 or PC5015 v1 x panel enter 5 d...

Страница 7: ...zones in 2 groups of 4 e g zones 9 12 and zones 13 16 None of the zones assigned to a PC5108 module may be used for wireless devices For more information on zone assignment consult your system Instal...

Страница 8: ...propriate options in programming sections 91 and 92 NOTE A wireless key can only be assigned to one partition 8 To exit press Program the WLS909 Function Buttons WLS909 wireless keys have four program...

Страница 9: ...ied Wireless Key Opening Closing option is only available with PC5010 PC5015 PC5008 PC1565 and PC585 v2 1 and higher To enable the reporting of openings by identified wireless keys Make sure the contr...

Страница 10: ...igned to one partition 8 To exit press Program the WLS910 Function Buttons WLS910 handheld keypads have four programmable function buttons You must program a set of four functions for the function but...

Страница 11: ...s 000000 The wireless device for the zone will be removed NOTE You may need to remove power from the panel in order to clear troubles caused by deleted zones Now that you have enrolled all the wireles...

Страница 12: ...e PC5132 RS receiver via the Keybus one minute after at least one device has been enrolled on the module The system will generate a General System Supervisory trouble if the module is removed from the...

Страница 13: ...program the wireless supervisory window 1 Enter 8 Installer Code to enter Installer Programming 2 Enter 804 to enter the PC5132 RS Module Programming 3 Enter sections 81 4 Enter the time period for th...

Страница 14: ...ettings To restore the PC5132 RS programming to the factory default settings perform the following 1 Enter 8 Installer s Code 2 Enter programming section 996 3 Enter the Installer s Code followed by 9...

Страница 15: ...plied magnet near the raised line on the outer rim of the bracket WLS905 WLS907 Open and close the contact by moving the magnet away from the unit If the unit is attached to a door or a window open an...

Страница 16: ...RS and the WLS904 WLS905 WLS906 and WLS907 devices and there is good reception between the PC5132 RS and the WLS908 WLS909 and WLS910 devices 5 3 Mount the PC5132 RS and Wireless Devices Do not perma...

Страница 17: ...LCD keypad s Trouble light will turn ON and the keypad will give a series of continuous beeps Instruct the user s to perform this test when they perform the weekly system test NOTE If a low battery c...

Страница 18: ...to test this device every week See section 5 4 for testing instruc tions The system will delay reporting the event to the central station for the number of days programmed for Zone Low Battery Transm...

Страница 19: ...t ESN was entered when the device was enrolled Verify that the device is in range of the PC5132 RS Try testing the device in the same room as the receiver Confirm that the PC5132 RS is properly connec...

Страница 20: ...__l 11 Zone 11 l_____l_____l_____l_____l_____l_____l 12 Zone 12 l_____l_____l_____l_____l_____l_____l 13 Zone 13 l_____l_____l_____l_____l_____l_____l 14 Zone 14 l_____l_____l_____l_____l_____l_____l...

Страница 21: ...Key 14 l_____l_____l_____l_____l_____l_____l 55 Key 15 l_____l_____l_____l_____l_____l_____l 56 Key 16 l_____l_____l_____l_____l_____l_____l Handheld Keypad and Wireless Key Function Key Options Sens...

Страница 22: ...unction Key 2 l____l____l Function Key 4 l____l____l Supervision 81 Wireless supervisory Window Default 03 l____l____l wireless device window hours valid entries are 01 24 NOTE Panic pendants are NOT...

Страница 23: ...ption 2 Zone 18 Supervision enabled Disabled l________l Option 3 Zone 19 Supervision enabled Disabled l________l Option 4 Zone 20 Supervision enabled Disabled l________l Option 5 Zone 21 Supervision e...

Страница 24: ...Wireless Key 04 on partition 2 On partition 1 l________l Option 5 Wireless Key 05 on partition 2 On partition 1 l________l Option 6 Wireless Key 06 on partition 2 On partition 1 l________l Option 7 Wi...

Страница 25: ...family unit Figure 3 A smoke detector should be located on each story of the living unit Figure 2 In the family living units with more than one sleeping area a smoke detector should be located to prot...

Страница 26: ...electronic serial 6 P panic pendant battery test 16 removing 13 replacing 17 supervision 13 partition program ming 12 handheld keypads 10 wireless keys 8 placement PC5132 RS 4 test 15 power 5 problem...

Страница 27: ...y for fail ure to repair the product under this warranty af ter a reasonable number of attempts will be lim ited to a replacement of the product as the ex clusive remedy for breach of warranty Under n...

Страница 28: ...1998 Digital Security Controls Ltd 1645 Flint Road Downsview Ontario Canada M3J 2J6 Tel 416 665 8460 Fax 416 665 7498 Tech Line 1 800 387 3630 Printed in Canada 29003020 R0...

Страница 29: ...Installation Manual PC5132 RS Version 3 0 Seepage 1for NEW features of v3 0...

Страница 30: ...ill not occur in a particular installation If this equipment does cause interference to television or radio reception which can be determined by turning the equipment off and on the user is encouraged...

Страница 31: ...reless Keys 9 3 5 Enrolling Programming Handheld Keypads WLS910 10 3 6 Deleting Wireless Devices 11 Section 4 Other Programming 12 4 1 Program Zones and Partitions 12 4 2 Enable PC5132 RS Supervision...

Страница 32: ...em may not properly alert occupants of a fire for a number of reasons some of which follow The smoke detectors may have been improperly in stalled or positioned Smoke may not be able to reach the smok...