[07] Keypad Lockout Options
Page 15
Default
0 0
Number of Invalid Codes before Lockout
0 0
Lockout Duration (minutes)
[08] First System Option Code
Page 15
Default
Zone Light ON
Zone Light OFF
OFF
Zone Light 1
N/C Loops
End-of-line Resistor Loops
ON
Zone Light 2
60 second bypass on power-up
Zones active on power-up
OFF
Zone Light 3
Force Arm on Auxiliary Delays
No Force Arm on Auxiliary Delays
OFF
Zone Light 4
Partial close on Auto-Arm
No partial close reported
OFF
Zone Light 5
Quick-Exit enabled
Quick-Exit disabled
OFF
Zone Light 6
PC16OUT enabled
PC16OUT disabled
OFF
Zone Light 7
AC excluded from Trouble
AC included in Trouble
OFF
Zone Light 8
For Future Use Zone Light 8 must be OFF at all times
[09] Second System Option Code
Page 16
Default
Zone Light ON
Zone Light OFF
OFF
Zone Light 1
Code 8: One-Time Use
Code 8: Normal Access Code
OFF
Zone Light 2
Master Code not changeable
Master Code changeable
OFF
Zone Light 3
Access Code required for Bypass
Access Code not required for Bypass
ON
Zone Light 4
Access Code to cancel Auto-Arm
No Access Code to cancel Auto-Arm
OFF
Zone Light 5
Access Code for Utility Output
No Access Code for Utility Output
ON
Zone Light 6
Alarms displayed while armed
Alarms displayed while disarmed only
OFF
Zone Light 7 Show bypass status while armed
Bypass status displayed if disarmed only
OFF
Zone Light 8 Show bypassed zones when armed
Bypasses zones displayed if disarmed only
[10] Third System Option Code
Page 17
Default
Zone Light ON
Zone Light OFF
OFF
Zone Light 1
2-minute Keypad Timeout
No Keypad Timeout
OFF
Zone Light 2
[F] Key disabled
[F] Key enabled
ON
Zone Light 3
[P] Key silent buzzer
[P] Key audible buzzer
OFF
Zone Light 4
[P] Key audible bell
[P] Key silent bell
OFF
Zone Light 5
Bell shutdown enabled
Bell shutdown disabled
OFF
Zone Light 6
Bell Squawk enabled
Bell Squawk disabled
ON
Zone Light 7
No bell during Auto-Arm
Bell during Auto-Arm
OFF
Zone Light 8
Exit Delay Termination Enabled
Exit Delay Termination Disabled
[11] Fourth System Option Code
Page 18
Default
Zone Light ON
Zone Light OFF
OFF
Zone Light 1
Bell pulses always
Bell pulses on Fire Alarm only
OFF
Zone Light 2
Bell Squawk on Exit Delay
No Bell Squawk
OFF
Zone Light 3
Bell Squawk on Entry Delay
No Bell Squawk
ON
Zone Light 4
Audible Exit Fault enabled
Audible Exit Fault disabled
ON
Zone Light 5
Audible exit with urgency
Standard Exit Delay
ON
Zone Light 6
Urgency on Entry Delay
Standard Entry Delay
OFF
Zone Light 7
TLM disabled
TLM enabled
OFF
Zone Light 8
TLM silent (trouble)
TLM audible if armed
Enter two 2-digit numbers in the range of 00
to 99. Program the number of Invalid Codes
as 00 to disable the lockout feature.
I______I______I I_______I_______I
I______I______I I_______I_______I
I___________I I___________I
I___________I I___________I
I___________I I___________I
I___________I I___________I
I___________I I___________I
I___________I I___________I
I___________I I___________I
I___________I I___________I
I___________I I___________I
I___________I I___________I
I___________I I___________I
I___________I I___________I
I___________I I___________I
I___________I I___________I
I___________I I___________I
I___________I I___________I
I___________I I___________I
I___________I I___________I
I___________I I___________I
I___________I I___________I
I___________I I___________I
I___________I I___________I
I___________I I___________I
I___________I I___________I
I___________I I___________I
I___________I I___________I
I___________I I___________I
I___________I I___________I
I___________I I___________I
I___________I I___________I
I___________I I___________I
I___________I I___________I