PowerSeries - PC1616/PC1832/PC1864
22
Section [404] Panel Identification Code
Program the 6-digit Panel Identification Code. This code is used by the downloading computer to verify the correct account is calling back
(Call Back feature) or to identify which customer account file should be used (User Initiated DLS and Auto Event Buffer Upload features).
Section [405] Double-Call Timer
Program the maximum time, in seconds, between calls when connecting to panel using the double call feature. Valid entries are
[000]
to
[255]
.
Section [406] Number of Rings to Answer On
Program the number of consecutive rings that panel must detect to answer for downloading. Valid entries are
[000]
to
[010]
.
Section [499] PC-Link Communications
Enter the following command to initiate downloading via PC-Link – Section
[499]
[Installer Code] [499]
. Plugging in the PC-Link connec-
tor will automatically initiate the connection if DLS is initiated before connecting the PC-Link Header. The session will NOT be automati-
cally initiated if the system is in installer mode.
Section [501] to [514] Programmable Output Attributes
These Sections are used to customize the operation of the PGM outputs (Section
[501]
for PGM 1, Section
[502]
for PGM 2 etc.). The avail-
able options depend on which PGM output type is programmed.
When the PGM Output Options (Section
[009]
to
[011]
) are programmed, the system will change the PGM Attributes to the default settings.
The PGM Attributes will default if a new PGM output option is programmed.
PGM Output Option [01], [03] to [08], [11] to [22], [25],[26], [28], [30], [33], [34]
PGM Output Option [19] to [22]
PGM Output Option [09
]
PGM Output Option [10]
Option
Description
[3]
ON
: the PGM output will operate normally (switch to ground when activated).
OFF:
the PGM output will be normally ground and switch
to open collector (open circuit) when activated.
Option
Description
[4]
ON:
the PGM output will activate for the duration of the PGM Output Timer when the
[ ][7][x]
command is performed.
OFF:
the PGM output will latch until the
[ ][7][x]
command is performed again.
[5]
ON:
a valid user code must be entered after the
[ ][7][x]
command.
OFF:
user code is not required.
Option
Description
[1]
ON:
PGM output activates if a Service Required trouble condition is present.
[2]
ON:
PGM output activates if an AC trouble condition is present.
[3]
ON:
PGM output activates if a Telephone Line trouble condition is present.
[4]
ON:
PGM output activates if a Failure to Communicate trouble condition is present.
[5]
ON:
PGM output activates if a Zone Fault condition is present.
[6]
ON:
PGM output activates if a Zone Tamper condition is present.
[7]
ON:
PGM output will activates if a Wireless Low Battery trouble condition is present.
[8]
ON:
PGM output will activates if a Loss of Clock trouble condition is present.
Option
Description
[1]
ON:
PGM output activates if a Burglary Alarm occurs.
[2]
ON:
PGM output activates if a Fire Alarm occurs.