PowerSeries - PC1616/PC1832/PC1864
8
Section 3: Programming
This section provides the information necessary to program all required features for a basic system as well as common applications. Refer to the
PC1616/1832/1864 Reference Manual
for a complete description of all programmable features.
3.1 Template Programming
Selecting
[ ][8] [Installer Code] [899]
displays the current 5 digit template programming code. Refer to Appendix C - Template Program-
ming for a detailed description of available templates and corresponding 5 digit codes. After entering a valid 5 digit template programming
code, you will be prompted to enter the following in the sequence indicated below:
1. Central Station Telephone Number, enter 32 Character Telephone number
Program the required Central Station phone number. Press
[#]
to complete your entry if less than 32 digits. This phone number will be
entered into programming section [301].
2. Central Station Account Code, enter 6-digit code
Program the required Central Station Account Code. Press
[#]
to complete your entry if less than 6 digits. This account code will be entered
into programming section [310].
3. Partition Account Code, enter 4-digit code
This programming section will only be prompted if Contact ID has been selected as a communications format. Program the required Parti-
tion Account Code. This Partition account code will be entered into programming section [311].
4. DLS Access Code, enter 6-digit code
Program the required DLS Access Code. Press
[#]
to complete your entry if less than 6 digits. This Access Code will be entered into
programming section [403].
5. Partition 1 Entry Delay 1, Partition 1 Exit Delay, enter each 3-digit delay time
Program the desired 3 digit Partition 1 Entry Delay (in seconds) followed by the desired 3 digit Partition 1 Exit Delay (in seconds). These
values will be entered in programming section [005] sub-section [01] entry 1 and 3 respectively.
6. Installers Code
Enter the required 4 or 6 digit access code installers access code (dependent on Section [701] option 5). This Installer Access Code will be
entered into programming section [006]. After the Installers Code has been programmed the keypad will return to base installers
programming menu.
3.2 DLS Programming
3.2.1 Local Programming:
Follow the steps below in the sequence indicated to set up local programming using DLS:
1. Initiate downloading using the DLS software
2. Connect an RS-232 to PC-Link Cable between the Computer with DLS Software installed and the alarm panel to be programmed.
3.2.2 Remote Programming (via telephone line):
Refer to Section [400] block on page 21 for details.
3.3 Advanced Keypad Programming
DSC recommends filling in the Programming Worksheet with the required programming information before programming the system. This
will reduce the time required to program and will help eliminate errors.
To enter Installer Programming press
[ ][8][Installer Code]
. The Program light will FLASH (programmable LCD keypad displays will
change to
‘Enter Section’
). An error tone indicates the installer code entered is incorrect, Press
[#]
to clear any key presses and try again.
This feature requires a PK55xx or RFK55xx series keypad, v.1.1 or higher.
All template programming information must be re-entered after performing a hardware or software
panel default.
Connecting the DLS PC to the panel will automatically initiate the connection.
The panel battery voltage can be monitored with DLS software.
After the panel information has uploaded, battery voltage can be viewed in the DLS session window.
The default Installer Code is [5555].