1.
Enter Installer Programming section [804][990] then select one of the following sub-sections:
l
[001] –Allzones
l
[002] –Repeaters
l
[003] –Sirens
l
[004] –Wirelesskeys
l
[005] –keypads
2.
Press [*] to select a wireless device type. The first available device is displayed.
3.
Use the scroll keys to view the enrolled devices.
Note:
This option is not fully supported by LED and ICON keypads.
[804][999] Reset to Factory Defaults
Selecting this option resets HSM2HOST programming to factory default settings.
[904] Placement Testing Wireless Devices
The following test modes are available:
l
[904][001]-[128] – Test wireless zones
l
[904][521]-[528] – Test all repeaters
l
[904][551]-[566] – Test all sirens
l
[904][601]-[632] – Test all wireless keys
l
[904][701]-[716] – Test all keypads
Two test results are provided:
l
24-hour: Average results of signal strength testing over a 24-hour period.
l
Now: Signal status results of the current test.
A flashing Trouble LED indicates RF interference. The following status indicators may be displayed:
LCD
Icon* LED+
Status
Strong
1
9
Strongsignalstrength
Good
2
10
Goodsignalstrength
Poor
3
11
Poor signalstrength
NotTest 5
13
Displayedasthe Nowresultif notestwasperformed
NotTest 5
13
Alwaysdisplayedasthe 24-hour resultwhentestingwirelesskeys
*For Icon keypads, digit 1 indicates 24-hour test results; digit 2 indicates Now test results.
+For LED keypads, the first digit indicates 24-hour results; the second digit indicates Now test results.
Note:
For EN/UL/ULC installations, only STRONG signal levels are acceptable.