![DSC LINKS1000 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/dsc/links1000/links1000_installation-manual_2534878016.webp)
16
HOOK-UP DIAGRAM - PC4010/PC4020/PC4020KT
N O T E S
1 An AC power supply must be dedicated to the LINKS1000. Do not use the security system's transformer to power the LINKS1000.
2 The LINKS1000 should be mounted as close as possible to the control panel to minimize the length of the wiring between the LINKS1000
and the control panel (max. 3ft apart).
3 Depending on the security requirements of the installation, the connections between the LINKS1000 and the control panel may need to be
protected in a damage and tamper resistant conduit. Knockout locations are provided on both the LINKS1000 cabinet and the control panel
cabinet for wiring between the cabinets and for the fitting of protective conduits.
This configuration is required on UL Listed systems.