Section 4: Programming Options
Fire Button Options
When this option is enabled, pressing and holding the Fire
[F] button on the wirefree keypad for 2 seconds triggers a
Fire alarm. The system sounds 3 beeps to acknowledge the
valid alarm and the siren sounds with a pulsing tone. An
alarm reporting code is transmitted to the central monitoring
station.
Default:
Enabled
Valid range:
Enabled/Disabled
Auxiliary Button Options
When this option is selected, pressing and holding the Aux-
iliary [A] button on the wirefree keypad for 2 seconds sends
an emergency alarm reporting code to the central mon-
itoring station. When the emergency reporting code is
received at the central monitoring station, the keypad beeps
10 times.
Default:
Enabled
Valid range:
Enabled/Disabled
Panic Button
When this option is selected, pressing and holding the Panic
[P] button for 2 seconds on the wirefree keypad sends an
emergency alarm reporting code to the central monitoring
station.
Default:
Enabled
Valid range:
Enabled/Disabled
Internal Buzzer Control
This option is used to set the volume level of the keypad’s
internal buzzer. The volume ranges from lowest (1) to
highest (15). Programming (0) turns off the buzzer.
Default:
7
Valid range:
0-15
Keypad Tamper
When this option is enabled, the wirefree keypad tamper
switch generates tamper alarms and restores when activ-
ated.
Default:
Disabled
Valid range:
Enabled/Disabled
Armed LED Power Save Option
This option is used to control the Armed LED on/off state. If
enabled, the Armed LED does not illuminate when the sys-
tem is armed to conserve battery life.
Default:
Disabled
Valid range:
Read-only
Auto Scroll Open Zones Option
When this option is enabled, the keypad automatically
scrolls through and displays all open zones.
Default:
Enabled
Valid range:
Read-only
Alarms Displayed While Armed Option
When this option is enabled, the keypad displays alarms on
affected zones while the system is armed.
If disabled, zones in alarm are not displayed while the sys-
tem is armed.
Default:
Enabled
Valid range:
Read-only
Power LED AC Present Option
When this option is enabled, the Power LED illuminates
when the iotega has electrical power.
When disabled, The Power LED illuminates when the iotega
does not have electrical power.
Default:
Enabled
Valid range:
Read-only
Auto Alarm Scroll Option
When this option is enabled, the keypad scrolls auto-
matically and displays all alarms when the bell is active or
when an alarm is in memory while armed.
Default:
Enabled
Valid range:
Read-only
Local Clock Display Option
When this option is enabled, the keypad displays the time
and date when not in use.
Default:
Enabled
Valid range:
Read-only
Keypad Lockout Duration
This option displays the length of time that the wirefree
keypad remains locked after the programmed number of
access code attempts has been exceeded.
Default:
5 Minutes
Valid range:
Read-only
4.7.2 Wireless Siren Configuration
Options
The following section provides descriptions of all wireless
siren programming options.
Siren Label
This option is used to program a label for the device.
Default:
Siren 1
Valid range:
32 character ASCI
Siren Enable/Disable
This option is used to enable and disable the wireless siren.
- 32 -