Section 4: Programming Options
Burglary Verification Selection
Use this section to select one of the following burglary veri-
fication timer modes:
001 Police Code
The Burglary Verification Timer operates in
minutes
002 Cross Zoning
The Burglary Verification Timer operates in
seconds. The first alarm in the sequence
does not log or communicate the alarm or
activate the bell.
003 Sequential Detection
The Burglary Verification Timer operates in
minutes. The first alarm in the sequence
causes an audible bell.
Burglary Verification Counter
This option is used to program the number of zone activ-
ations required to verify an alarm.
Default:
002
Valid range:
000 to 255
Burglary Verification Timer
If more than one zone with the Burglary Verification attribute
enabled is tripped within the duration of this timer, a burglary
verified event is communicated and logged. "Burglary Veri-
fied" is displayed on the keypad when the system is dis-
armed.
Default:
060 minutes
Valid range:
000 to 255 minutes
Default Master Code
This function is used to reset the master code to factory
default. When this is done, the master user is notified via
email or text if configured.
Default Master Code is available through the installer portal
only.
Access Code Required For Bypassing
When this option is enabled, an access code is required to
view the zone bypass menu.
When this option is disabled, the zone bypass menu is
accessible to anyone.
Default:
Disabled
Valid range:
Enabled/Disabled
RF Jam
When this option is enabled, the alarm panel detects and
reports continuous wireless signals that could interfere with
the operation of the alarm system.
Default:
Disabled
Valid range:
00: Disabled, 01: UL 20/20, 02: EN 30/60, 03: Class 6 30/60
Installer Access Window Permission
When this option is enabled, the installer is given access to
the panel’s programming sections for a 4-hour window, or
until the install has been finalized.
When this option is disabled, the installer can access the
panel’s programming sections at any time.
This option is controlled by Level 1 users.
Default:
Enabled
Valid range:
Enabled, Disabled
Ethernet IP Address
This is the resolved value based on the DHCP address
assignment.
Default:
000.000.000.000
Valid range:
Read-only
Ethernet IP Subnet
This is the resolved value based on the DHCP address
assignment.
Default:
255.255.255.000
Valid range:
Read-only
Gateway IP Address
This is the resolved value based on the DHCP address
assignment.
Default:
000.000.000.000
Valid range:
Read-only
DNS 1 IP Address
This is the resolved value based on the DHCP address
assignment.
Default:
000.000.000.000
Valid range:
Read-only
DNS 2 IP Address
This is the resolved value based on the DHCP address
assignment.
Default:
000.000.000.000
Valid range:
Read-only
Access Code Required to View/Silence Troubles
This option is used to enable and disable the need to enter
an access code before viewing and silencing system
troubles.
Default:
Disabled
Valid range:
Enabled, Disabled
Cellular Low Signal Trouble
This option is used to determine if the system will generate a
trouble event when a weak cellular signal is detected.
When enabled, a trouble event is generated if the radio sig-
nal level falls below threshold level (average CSQ level 4 or
less).
Default:
Enabled
Valid range:
Enabled, Disabled
- 20 -