GS3125/GS3105
75
G
G
G
G
G
Remote programming with the DLS IV INT software
To remotely program the control panel, you must have installed the DLS IV INT software application on your PC with the
driver update package downloaded from the SDC site.
CAUTION: in order to get support on DLS IV INT for GS3125, you must install the “Driver pack for the GS3125”.
Before you start a remote connection via GPRS between the Communicator and the DLS IV INT software application, you
need to send an SMS message to the Communicator using a GSM phone, so you will need to know the telephone number
assigned to the SIM card. The “SMS Message Generator” window of the DLS IV INT software shows the information
needed to create the text of the SMS message to send to the Communicator. To see this window, perform the following steps:
1. Start up the DLS IV INT software on your PC.
2. Create a “New Account” by set the type of control panel (for example, PC1864 v4.2EU) and the “Connection Type”,
for example “SMS (GS GS3125)”.
3. After you have entered the required information, click on “Create”.
4. Go to the GS/IP section of the menu and enter the Installers Code in the “GS/IP Installers Code” field (max 4 digits, see
the “Programming from PC>Options>Codes>Installer Code” option) and the “IMEI” number of the Communicator.
5. Click on the “Global Upload” icon and select SMS as the “Connection Type” - then click on “OK”.
6. The “SMS Message Generator” window will be displayed, showing the information needed to create the text of the SMS
message (e.g.: #DLS#11122233344451004).
7. In the “SMS Message Generator” window, click on “OK”. The DLS IV INT software application will wait for a connection
with the Communicator.
8. Send the SMS message to the Communicator via your GSM phone.
9. After receiving the SMS message, if correct, the Communicator opens a remote connection via GPRS with the DLS IV INT
software application. The DLS INT IV software application can now communicate remotely via GPRS with a Power Series
PC1864 control panel.
2. The operator enters
the text of the SMS message
on his/her phone by copying
the information displayed
3. The SMS message with a public
IP and DLS port is sent to the
GS3125/GS3105.
DSC’s POWER SERIES
CONTROL PANEL
5. DLS communicates with
the DSC control panel
(Options Upload/Download)
via the GS3125/GS3105.
4. The GS3125/
GS3105 connects via
GPRS to the DLS
Fig. 7 - Remote programming with the DLS IV INT software.