6
HSPA(3G)/Dual Alarm Communicator Installation Manual
bracket. Push the communicator firmly and evenly onto the standoffs until it is securely
attached to the mounting bracket.
d. Remove the panel front cover.
e. Remove and discard the circular knockout located in the top-right section of the panel. (This
hole will be used for connection of the supplied radio antenna).
f. Connect the supplied 5” (12.7 cm) antenna cable to the radio, by passing the connector
through the hole on back of the mounting bracket to the communicator board. Push the
antenna connector firmly into the socket on the cellular radio. (See
2. Install the Communicator into the panel:
a. Attach one end of the PC-LINK cable to the panel PCLINK_2 header on the panel (red wire
goes on the right-hand pin of the
panel
PCLINK_2 header (see
b. Insert the assembled communicator into the panel.
NOTE:
Ensure that the threaded antenna connection point is visible through the knockout hole at
the top right of the panel.
c. Place the nylon washer with bushing (thick flat washer) onto the threaded section of the
antenna cable. Insert the threaded section through the antenna mounting knockout hole at top
right of panel.
d. Place the second nylon washer (flat), followed by the brass washer and the brass nut, onto
the threaded section of the cable,
outside
the panel. Tighten the assembly by hand only (fin-
ger tight only- do not over tighten the antenna assembly).
e. Locate the screw hole on the right side wall of the
panel. See
screw. Line up the assembled
communicator with the right side wall of the panel
and, using the screw provided, secure the mount-
ing bracket to the panel.
f. Attach the other end of the PC-LINK cable to the
communicator (red wire goes on the right-hand pin
of the
communicator
PC-LINK header
(See
)).
g. Using light pressure (finger tight only), attach the
supplied white quad band whip antenna to the
threaded antenna connection point at top of the
panel.
WARNING! - 3G2080(R)/TL2803G(R) modules are
power limited. Do not route any wiring over the cir-
cuit board. Maintain at least 1in. (25.4mm) separa-
tion between circuit board and wiring. A minimum
of ¼ in. (7mm) separation must be maintained at
all points between non-power limited wiring and
power limited wiring.
3. To electrically connect the communicator to the panel, perform the following steps (See
a. Disconnect both AC power and battery connections from the panel, and disconnect tele-
phone line.
b. Confirm that the SIM card is inserted in the holder and locked.
4. Install Network Cable (TL2803G(R) only). Route the CAT 5 Ethernet cable through back of the
panel and plug it into the communicator’s RJ45 jack.
NOTE:
Before leaving the premises the Ethernet communication lines must first be connected to
an approved (acceptable to local authorities) type NID, (UL installations, UL 60950 listed
NID, for ULC installations CAN/CSA C22.2. No. 60950-1 certified NID). All wiring
shall be performed according to the local electrical codes.
PC-Link
cable connector
screw
quad band
whip antenna
GSM Radio
RJ-45
UA601
Use light pressure
to attach antenna
finger tight
only.
HS2016/2032/2064/2128