HSPA(3G)/Dual Alarm Communicator Installation Manual
Ratings Compatibility
NOTE:
Enter [*][8][Installer Code][900] at keypad to view the panel version number.
Products or components of products, which perform communications functions only shall comply
with the requirements applicable to communications equipment as specified in UL60950 or CAN
CSA C22.2. No. 60950-1, Information Technology Equipment - Safety - Part 1: General Require-
ments. Where network interfaces are external to the control unit or receiver, compliance to CAN
CSA C22.2. No. 60950-1 is adequate. Such components include, but are not limited to: hubs; rout-
ers; NIDs; third-party communications service providers; DSL modems; and cable modems.
This HSPA(3G)/dual-path alarm communicator shall be installed by service persons only (service
person is defined as a person having the appropriate technical training and experience necessary to
be aware of hazards to which that person may be exposed to in performing a task and can also take
measures to minimize the risks to that person or other persons). The Communicator shall be
installed and used within an environment that provides the pollution degree max 2, overvoltages
category II, in non-hazardous, indoor locations only. This manual shall be used with the installa-
tion manual of the panel which is connected to the communicator. All instructions specified within
the panel manual must be observed.
All the local rules imposed by local electrical codes shall be observed and respected during instal-
lation.
Installing the Ethernet Cable(TL2803G(R) Only)
A Category 5 (CAT 5) Ethernet cable must be run from a source with Internet connectivity to the
communicator module, inside the panel. The communicator end of the cable must be terminated
with an RJ45 plug, which will connect to the communicator’s RJ45 jack after the communicator is
installed. All requirements for installation of CAT5 Ethernet cable must be observed for correct
operation of the communicator, including, but not limited to, the following:
Table 1: Communicator Ratings
Model
3G2080(R)
Cellular only
TL2803G(R)
Internet and Cellular
Power Supply Ratings
Input Voltage
10.8-12.5 VDC
Power is supplied from the panel’s PC-Link header or a PCL-422 module in
remote cabinet installations. In remote cabinet installations, the PCL-422 module
located with the communicator is powered by either an HSM2204 or an
HSM2300. Refer to the PCL-422 installation instructions for details.
Current Consumption
Standby Current
90mA @ 13.66V
120mA @ 13.66V
Alarm (Transmitting) Current
400mA @ 12V
Operating Frequency
850MHz, 1900MHz
Typical Antenna Gain
2dB
i
Environmental Specifications
Operating Temperature
14°F to 131°F (-10°C to 55°C)
Humidity
5% ~ 93% relative humidity, non-condensing
Mechanical Specifications
Board Dimensions (mm)
100 × 150 × 15
100 × 150 × 15
Weight (grams) with bracket
310
320
Table 2: Compatible Receivers, and Panels
Communicator
Receiver/
Panel
Description
3G2080(R)
TL2803G(R)
Receiver
• Sur-Gard System I-IP Receiver, version 1.13+
• Sur-Gard System II Receiver, version 2.10+
• Sur-Gard SG-DRL3-IP, version 2.30+ (for Sur-Gard System III Receiver)
• Sur-Gard SG-DRL4-IP version 1.20+ (for Sur-Gard System IV Receiver)
• Sur-Gard SG-DRL5-IP version 1.00+ (for Sur-Gard System 5 Receiver)
Panel
• HS2016
• HS2032
• HS2064
• HS2128
C
OMMUNICATOR
I
NSTALLATION
C
ONFIGURATION