1.    Introduction

DRU, a manufacturer of gas-fired heating appliances, develops and produces products that comply with the
highest possible quality, performance and safety requirements. This appliance has a CE label, which means that it
complies with the essential requirements of the European Gas Appliance Directive. The appliance is supplied with
an installation manual and a user manual. As an installer, you must be certified and competent in the field of
gas-fired heating and electricity. The installation manual will give you the information you need to install the
appliance in such a way that it will operate properly and safely.

This manual discusses the installation of the appliance and the regulations that apply to the installation. In
addition, you will find technical data for the appliance and information on maintenance, any malfunctions that
might occur and their possible causes.

The figures can be found at the back of this booklet, in the appendix.
Please, read and use this installation manual carefully and completely, prior to installing this appliance. If you use
the DRU Powervent system® or the DRU Smartvent system®, you must carefully and fully read and use the
accompanying installation manual as well, prior to its installation.

The following symbols are used in the manuals to indicate important information:

Ø

Work to be performed

!Tip

Suggestions and recommendations

!Caution

You will need these instructions to prevent problems that might occur during installation and/or use.

!Caution

You need these instructions to prevent fire, personal injury or other serious damages.

After delivery, you should give the manuals to the user.

 

2.    CE declaration

We hereby declare that the design and construction of DRU's gas-fired heating appliance comply with the
essential requirements of the Gas Appliance Directive.

Internal precautions at the company will guarantee that appliances produced in series comply with the essential
requirements of the EC directives in force and the standards derived from them. This declaration will lose its
validity if adjustments are made to the appliance without prior written permission by DRU.
You will be able to download a copy of the test certificate via www.druservice.com.

M.J.M. Gelten
General manager
Postbus 1021, 6920 BA Duiven
Ratio 8, 6921 RW Duiven
www.dru.nl

Product:
Type:
EEC directives:
Standards:

gas-fired heating appliance
Excellence 60
2009/142/EC; 2006/95/EC; 2004/108/EC
NEN-EN-613; NEN-EN-613/A1; EN60335-2-102

UK

Содержание Excellence 60

Страница 1: ...E n g l i s h Store this document in a safe place Excellence 60 Installation manual UK IE DRU132368 162441 EN 0914 6 G20 G25 Natural gas UK 959 043 05 UK...

Страница 2: ...chimney breast 5 7 Placing the control hatch 5 8 Flue gas discharge system appliances open combustion 5 9 Flue gas discharge combustion air supply system appliances closed combustion 5 10 Additional i...

Страница 3: ...martvent system you must carefully and fully read and use the accompanying installation manual as well prior to its installation The following symbols are used in the manuals to indicate important inf...

Страница 4: ...place heat resistant electrical wiring away from the appliance and as low as possible in the chimney breast This has to do with the temperature development in the chimney breast if you are installing...

Страница 5: ...e of switching on manually the appliance will first return to full load Caution The appliance s control unit is characterized by its stringent safety requirements It is possible that the burning appli...

Страница 6: ...connection away from the appliance as low as possible in the chimney breast This has to do with the temperature development in the chimney breast If possible place the receiver after any building wor...

Страница 7: ...he control hatch see section 5 7 Proceed as follows Remove the bracket with amongst other things the gas control from the appliance by unscrewing the self tapping screws Place the bracket to which amo...

Страница 8: ...chimney breast You can use DRU ventilation elements Prior to completely closing the chimney breast check whether the discharge concentric system is placed correctly whether the channels fixing bracket...

Страница 9: ...rge only allowed in Great Britain the instructions provided in the separately supplied booklet Fitting into a conventional class 1 chimney apply In addition to the installation instructions this bookl...

Страница 10: ...em with wall or roof terminal has to comply with the following conditions In appendix 2 table 4 or 5 you can find whether a concentric pipe should be connected and what the minimum vertical length wou...

Страница 11: ...e clip binding to the pipe on locations that cannot be reached after installation Apply sufficient wall brackets so that the weight of the pipes does not rest on the appliance Determine the remaining...

Страница 12: ...e glass window towards you 2 through the opening in the mounting frame and pull the top of the glass window towards you at the same time Caution Make sure you hold the handgrip firmly If you let go of...

Страница 13: ...ndix 3 Fig 10 B Unscew the self tapping screws of the left and right large air inlet guide C Replace the large air inlet guides by the smaller versions see Appendix 3 Fig 11 D Tighten the small air in...

Страница 14: ...sten the glow material under chips and or wood set Caution The logs should not completely cover the burner cartridge because in that case the main burner will not ignite properly which could result in...

Страница 15: ...wall make sure the construction frame is level with the wall Place the mantelpiece in front of the fire see Appendix 3 Fig 30 place the lower plate E of the mantelpiece in the middle in front of the f...

Страница 16: ...ormation stored in the receiver In this way the last 20 error messages can be retrieved and it will also be possible to read how many times an error occurred Moreover this remote control can also be u...

Страница 17: ...ording to the instructions in the manual that is supplied with this module Now follow the steps described in the modbus protocol manual It is available from the supplier of the domotics system 6 2 2 2...

Страница 18: ...t the system as described and repeat the ignition procedure until the main burner continuous to burn Caution The system can be reset and re ignited three times in a row at maximum After that the syste...

Страница 19: ...f the flame picture is not acceptable in order to solve the problem 8 Maintenance Once a year the appliance should be checked cleaned and if necessary repaired by a competent installer in the field of...

Страница 20: ...openers Point out the 230 Volt connection Instruct the user about the appliance and the remote control When the appliance is taken into operation point out that in order to avoid cracks in a chimney b...

Страница 21: ...pin suffocating flame Ionization pin placed incorrectly Ionization pin blocked measure ionization flow when 0 and 1 8 uA Make sure the connectors of the communication cable make proper contact Replac...

Страница 22: ...from burner device Burner device incorrectly mounted Pins on the connector on the gas control are bent High limit bridge defective ESYS defective burner device Window is open if this contact is presen...

Страница 23: ...restrictor slide Restrictor slide Key bolts M8x140x50 Back up self tapping screws for mounting the glass panes Socket spanner 8 mm Remote control Hexagonal nut M8 Washer 8 4 mm U profile for decoratio...

Страница 24: ...ominal output Consumption Main burner injector Second burner injector Overflow burner injector Low setting injector Burner pressure on low output Consumption on low output Efficiency class Excellence...

Страница 25: ...length 0 51 1 4 1 4 Total number of meters horizontal pipe length excluding wall terminal 0 1 0 1 to 3 Table 4 Conditions for setting the appliance See Figure 5 5 5 Air inlet guide SMALL LARGE2 SMALL...

Страница 26: ...conditions concentric system with roof terminal UK Table 5 Determining permissibility concentric system with roof terminal Total number of meters horiz pipe length Total no of meters vertical and or s...

Страница 27: ...E n g l i s h INSTALLATION MANUAL UK 620 600 min 1064 max 1084 50 626 815 100 150 B B 152 360 18 606 min 163 max 183 38C 1701 2 Excellence 60 1...

Страница 28: ...E n g l i s h INSTALLATION MANUAL UK min 160 610 min 350 630 min 15 max 100 min 1220 min 360 2 2 A 2 2 B 38C 1704 V Tot min 200cm A B B H D G F E A C 38C 1747 0 3 2...

Страница 29: ...E n g l i s h INSTALLATION MANUAL UK 38C 1868 0 4...

Страница 30: ...E n g l i s h INSTALLATION MANUAL UK 38C 1716 1 2 A B 1 0 5m 0 1m 38c 744t 1x90 1 4m 0m 38c 744q 1x90 1 4m 1 3m 38c 744s 1x90 U V T X 38C 1705 S 5x 1 2 3 38C 1718 6 5 5 7 5 8...

Страница 31: ...E n g l i s h INSTALLATION MANUAL UK T Q P S 9x 38C 1709 0 R U A 38C 1706 2x C 38C 1707 2 B D 38c 1708 2 2x 12 9 10 11...

Страница 32: ...E n g l i s h INSTALLATION MANUAL UK 30 40 38C 1710 38p 0229 38p 0230 38p 0022 38p 0023 38P 0028 1 16 13 14 17 18 15...

Страница 33: ...E n g l i s h INSTALLATION MANUAL UK 38P 0235 G A A F E D C B 19...

Страница 34: ...E n g l i s h INSTALLATION MANUAL UK 38P 0233 38P 0234 A A 38P 0236 B C 20 21 22...

Страница 35: ...E n g l i s h INSTALLATION MANUAL UK 38P 0237 F E G D B 2x 8x 38C 1750 A 24 23...

Страница 36: ...E n g l i s h INSTALLATION MANUAL UK I J H J L 1 2 4 3 I K 38C 1751 1 M 2x 38C 1752 1 149mm 4x A A 149 38C 1753 S C 2x 15 30mm 38C 1754 min 875 min 715 38C 1711 26 25 27 28 29...

Страница 37: ...E n g l i s h INSTALLATION MANUAL UK D A 38C 1756 F E D A F G 38C 1757 G 31 30...

Страница 38: ...E n g l i s h INSTALLATION MANUAL UK 38C 1871 0 Modbus WiFi Router W R D B O A 0 3 V 38p 0320 0 N L 0 3V L N N L B A C D 36 35...

Страница 39: ...E n g l i s h INSTALLATION MANUAL UK 1 98 Off 1 98 Off B2 B1 B U B U C B D 38p 0318 3 P1 P2 G IN A E 38 37...

Страница 40: ...E n g l i s h DRU Verwarming B V The Netherlands Postbus 1021 NL 6920 BA Duiven Ratio 8 NL 6921 RW Duiven UK...

Отзывы: