background image

English

I N STA LLAT IO N M AN UAL

 

Ø

If applicable, do not plaster on or over the edges of the construction frame, because:

the heat of the appliance could cause cracks;

it will no longer be possible to remove/place the glass pane.

Ø

When using stone-like materials and/or a plaster finishing, allow the chimney breast to dry for at least six weeks 
prior to using the appliance in order to prevent cracks.

5.6 Placing the control hatch

 (if applicable)

The control hatch (also see paragraphs 5.4 and 5.5) is placed as low as possible in the chimney breast.
 

!Caution

The bottom of the control hatch may not be placed higher in the appliance than the burner surface.

Place control hatch and bracket with gas control and accessories indoors in a dry place only!

 
A number of components are placed in the control hatch, such as data plate, gas control, receiver belonging to the 
remote control and, if applicable, the components belonging to the DRU Powervent system

®

.

 
Place the control hatch as follows; see Appendix 3, fig. 3 for details:

Ø

Make an opening in the chimney breast, as described in the manual for the control hatch.

Ø

Place the inner frame (1); unscrew bolts (5) for this.
 

!Tip

When the chimney breast is made of bricks, the inner frame can be built with bricks at the same time

When using a different material, you can glue the inner frame or fix it with four flush screws.

 

Ø

Mount the gas control to the brackets of the inner frame (2).

Ø

Check whether pipes and connections are free from dirt;

Ø

Reconnect the pipes to the gas control.
 

!Caution

Avoid kinks in the pipes;

Tighten the flexible gas pipe and the pilot burner pipe until they are gastight.

First tighten the thermocouple by hand and;

Then tighten it a quarter turn using a suitable spanner;

The pilot burner pipe must be protected against possible corrosive influences as a result of, for example, 
humidity, cement that has fallen down, dirt that has fallen down from the chimney, etc. The pilot burner pipe 
should remain permanently free from the ground and the walls of the room in which the appliance is built in. 
When installing in an existing fireplace, or if it is not possible to keep the pipes free, the pipe should be 
protected against corrosion by means of a jacket.

Ø

Prevent dirt in gas pipes and connections.

Ø

Connect the gas pipe to the gas tap.

Ø

Bleed the gas pipe.

Ø

Place the receiver in the holder (3); for connecting, see section 6.1.

Ø

Place the data plate in its intended clamp (6).

Ø

Fix the outer frame with door (4) to the inner frame using 2 socket cap screws (5).
 

!Tip

You can place the outer frame in such a way, that the door turns to the left or to the right.
 

5.7 Flue gas discharge system in appliances with open combustion

For connection to an existing chimney without a discharge pipe or flexible SS discharge - only allowed in Great 
Britain - the instructions provided in the separately supplied booklet 'Fitting into a conventional class 1 chimney' 
apply. In addition to the installation instructions, this booklet also contains supplementary tests. In this situation 
we recommend using a stainless steel flexible discharge pipe over the complete length, with a draught increasing 
hood.
 

5.7.1 General

The connection dimensions and the minimum length of the discharge system are indicated in Annex 2, table 2. 
The appliance should be connected in accordance with the applicable national, local and constructional 
(installation) regulations. You should only install the appliance in a well ventilated room which complies with the 
applicable national, local and constructional (installation) regulations, in order to guarantee sufficient air supply.

8

Содержание 0063CU3544

Страница 1: ...E n g l i s h Store this document in a safe place Global 70XT CF 01 RCE Installation manual DRU 881801 EN US 0420 6 G20 G25 G25 3 Natural gas G31 Propane EN 959 123 01 EN...

Страница 2: ...Construction of the concentric system 5 8 3 Placing the concentric system 5 8 4 Connection existing chimney 5 9 Additional instructions 5 10 Placing the appliance 5 10 1 Connecting the appliance 5 10...

Страница 3: ...completely prior to installing this appliance If you use the DRU Powervent system or the DRU Smartvent system you must carefully and fully read and use the accompanying installation manual as well pri...

Страница 4: ...re there is sufficient ventilation of the room where the appliance is installed according to legislation If you are installing an appliance with a closed combustion only use the concentric systems sup...

Страница 5: ...iance Check the appliance and accessories for damages during transport If necessary contact your supplier Never install an appliance that is damaged Remove any screws that are used to fix the applianc...

Страница 6: ...nket or any other material Make sure that the appliance to be installed has a stable position Attach the appliance if applicable to the wall using the wall brackets and or fasten the extending legs wi...

Страница 7: ...top of the chimney breast the material inside the chimney breast and the back wall of the chimney breast Make sure that the appliance is not carrying the weight of the chimney breast when using stone...

Страница 8: ...arter turn using a suitable spanner The pilot burner pipe must be protected against possible corrosive influences as a result of for example humidity cement that has fallen down dirt that has fallen d...

Страница 9: ...with the CE mark Caution Some heat resistant insulation materials contain volatile components that will spread an unpleasant smell during a longer period these are not suitable Place the flue gas disc...

Страница 10: ...lacing the concentric system Caution Maintain a distance of at least 50 mm between the outside of the concentric system and the walls and or ceiling If the system is built in for instance a cove it sh...

Страница 11: ...chimney with a fitting diameter at the flue gas discharge pipe for the discharge of flue gas The surrounding space is used to supply combustion air The following requirements apply when connecting to...

Страница 12: ...the appliance using the holes in the flange at the front Remove the glass pane see section 5 12 1 Connect the appliance see section 5 10 1 Caution Do not ignite the appliance until it is fully instal...

Страница 13: ...ndix 2 tables 5 and 6 Remove the restrictor from the flue spigot see Appendix 3 fig 16 R Break both rings A from the restrictor by moving it back and forth until it comes off A large passage will rema...

Страница 14: ...tes are provided with round holes these holes supply air Do not place more than one layer of chips over these holes Place log D over the positioning cam The positioning cam should fall into the slot o...

Страница 15: ...in order to avoid damaging the receiver Avoid formation of dust on or in the receiver cover it when performing work Place the receiver in its intended holder under the appliance or in the control hat...

Страница 16: ...ow position ignition and switching off Tip If the external control system has an intelligent clock function and or thermostat function the remote control supplied with the appliance should have the ma...

Страница 17: ...ches off after 22 seconds This happens because the appliance is equipped with a second thermocouple and the glass window has not been placed In this case you may presume that the main burner will cont...

Страница 18: ...he system as a result of pitting corrosion If required clean the following components the pilot burner malfunction search diagram Appendix 1 the space surrounding the pilot burner the glass pane s Cau...

Страница 19: ...door openers Instruct the user about the appliance and the remote control When the appliance is started for the first time point out that In order to avoid cracks in a chimney breast made of stone lik...

Страница 20: ...bend tip 1 mm higher Spark too weak thin and reddish Act as if no spark in box 2 05 and perform actions described for ignition cable and ignition electrode Pilot flame too weak dirty Remove injector r...

Страница 21: ...venly distributed across burner s chips on burner lack of combustion air See 2 15 cross lighting in low setting possible when thermostat function is used 2 15 Check Gas supply Supply pressure does not...

Страница 22: ...and brief noise of servomotor to confirm that communication code was set succesfully Remote control Battery 9V empty see indication on display Several After switching off going out the remote set is l...

Страница 23: ...ons conventional class 1 chimney Sealing tape Cellular rubber Debris shield Spare self tapping screws for mounting glass panes Socket spanner 8 mm Remote control with receiver 9V block battery Penlite...

Страница 24: ...31 No 4 6 119 5 4 6 4 0 6 7 6 2 252 219 21 6 16 4 2x 0 70 1x 0 75 1x 0 85 1 80 2 74 3 68 3 74 D Unit kW kW mg kWhinput GCV kW kW kW kW L h L h mbar mbar mm mm kW kW kW kW Type of heat output room temp...

Страница 25: ...using G31 Total number of meters vertical pipe length N A Total number of meters horizontal pipe length excluding wall terminal N A Table 4 Conditions for setting the appliance See Figure N A Air inle...

Страница 26: ...length Total no of meters vertical and or sloping pipe length no bends 2 bends 3 bends 4 bends 5 bends Situation is not permissible min length 3 m angles in vertical direction of flue gas discharge s...

Страница 27: ...i s h INSTALLATION MANUAL Appendix 3 Figures 27 600 720 835 15 23 5 811 100 757 899 126 345 18 621 145 810 38C 2634 0 min 901 min 500 761 max 100 365 625 min 143 V V Tot min 200 cm2 38c 2635 0 2 2 B...

Страница 28: ...E n g l i s h INSTALLATION MANUAL 28 300 150 450 150 150 A B 38c 2111 0 38c 2636 0 38c 2637 0 38c 2638 0 38c 2639 0 6 5 7 8 9...

Страница 29: ...E n g l i s h INSTALLATION MANUAL 29 3 8 C 2 6 4 2 0 24 118 38c 2643 0 38c 2640 0 38c 2641 0 13 10 11 12...

Страница 30: ...E n g l i s h INSTALLATION MANUAL 30 38C 2646 0 A X 6 m B X 6 m X R 38c 2644 0 38c 2645 0 16 14 15...

Страница 31: ...E n g l i s h INSTALLATION MANUAL 31 38P 0822 0 38P 0823 0 38p 0022 38P 0608 38P 0028 1 21 17 18 19 20...

Страница 32: ...E n g l i s h INSTALLATION MANUAL 32 38P 0806 0 A B C D E F G H A B 38P 0824 0 C 23 22...

Страница 33: ...E n g l i s h INSTALLATION MANUAL 33 38P 0825 0 F D 38P 0826 0 E 25 24...

Страница 34: ...E n g l i s h INSTALLATION MANUAL 34 H 38P 0827 0 G 38p 0179 38p 0181 5mV 38p 0182 38 26 40 41 42...

Страница 35: ...E n g l i s h INSTALLATION MANUAL 35 38C 1940 38c 2647 0 16 18 38c 2648 0 44 43 43b...

Страница 36: ...E n g l i s h DRU Verwarming B V The Netherlands Postbus 1021 NL 6920 BA Duiven Ratio 8 NL 6921 RW Duiven EN...

Отзывы: