English
I NS TA LL AT ION MA NU AL
24
Gastype:
Indirect heating functionality
Direct heat output
Indirect heat output
Space heating emissions NO
x
Heat output
Nominal heat output
Minimum heat output (indicative)
Technical data
Nominal heat input (Hs)
Nominal heat input (Hi)
Consumption max
Consumption min
Burner pressure max
Burner pressure min
Main burner injector
Low setting injector
Efficiency class (EN613)
Useful efficiency (NCV)**
Useful efficiency at nominal heat output
Useful efficiency at minimum heat output
(indicative)
Auxiliary electricity consumption
At nominal heat output
At minimum heat output
In standby mode
Permanent pilot flame power requirement
Pilot flame power requirement (if applicable)
Energy efficiency
Energy efficiency index
Energy efficiency class
Symbol
P
nom
P
min
η
th,nom
η
th,min
el
max
el
min
el
SB
P
pilot
EEI
G25/G25.3*
No
4,4
-
117,5
4,4
2,7
6,4
5,8
687
474
14,0
6,8
2x Ø 1,10
2x Ø 1,05
1,80
2
75,9
67,4
-
-
-
-
76
D
G20
No
4,5
-
113.3
4,5
3,1
6,8
6,1
644
448
11,3
5,5
2x Ø 1,10
2x Ø 1,05
1,80
2
77,1
72,2
-
-
-
-
77
C
G31
No
4,6
-
119,5
4,6
4,0
6,7
6,2
252
219
21,6
16,4
2x Ø0,70
1x Ø0.75
1x Ø0,85
1,80
2
74.3
68.3
-
-
-
-
74
D
Unit
kW
kW
mg/kWh
input
(GCV)
kW
kW
kW
kW
L/h
L/h
mbar
mbar
mm
mm
%
%
kW
kW
kW
kW
Type of heat output / room temperature control
Single stage heat output, no room temperature control
Two or more manual stages, no room temperature control
With mechanic thermostat room temperature control
With electronic room temperature control
With electronic room temperature control plus day timer
With electronic room temperature control plus week timer
Other control options
Room temperature control, with presence detection
Room temperature control, with open window detection
With distance controle option
No
No
No
Yes
Yes
Yes***
Yes***
Yes***
Yes
Global 70XT CF-01 RCE
Built-in
Open combustion
B
11AS
I
2EK
, I
2ELL
, I
2H
, I
2E+
, I
2E
, I
3P
Ø 100 mm / 3 m
Oxypilot with thermocouple
yes
yes
no
200 cm
2
* This appliance is suitable for G25.3 with the composition according NTA 8837.
** System efficiency.
*** To be used by means of home automation.
Model identifier(s)
Type of appliance
Combustion
Type
Categorie
Appliance connection
Flame protection version
2nd thermocouple safety
Atmosphere safety
Explosion hatch
Ventilation hole chimney breast
Table 2: Technical data
Содержание 0063CU3544
Страница 29: ...E n g l i s h INSTALLATION MANUAL 29 3 8 C 2 6 4 2 0 24 118 38c 2643 0 38c 2640 0 38c 2641 0 13 10 11 12...
Страница 30: ...E n g l i s h INSTALLATION MANUAL 30 38C 2646 0 A X 6 m B X 6 m X R 38c 2644 0 38c 2645 0 16 14 15...
Страница 31: ...E n g l i s h INSTALLATION MANUAL 31 38P 0822 0 38P 0823 0 38p 0022 38P 0608 38P 0028 1 21 17 18 19 20...
Страница 32: ...E n g l i s h INSTALLATION MANUAL 32 38P 0806 0 A B C D E F G H A B 38P 0824 0 C 23 22...
Страница 33: ...E n g l i s h INSTALLATION MANUAL 33 38P 0825 0 F D 38P 0826 0 E 25 24...
Страница 34: ...E n g l i s h INSTALLATION MANUAL 34 H 38P 0827 0 G 38p 0179 38p 0181 5mV 38p 0182 38 26 40 41 42...
Страница 35: ...E n g l i s h INSTALLATION MANUAL 35 38C 1940 38c 2647 0 16 18 38c 2648 0 44 43 43b...
Страница 36: ...E n g l i s h DRU Verwarming B V The Netherlands Postbus 1021 NL 6920 BA Duiven Ratio 8 NL 6921 RW Duiven EN...