background image

 
 

20 

 

 

 
Dropsa Spa 

Via Benedetto Croce, 1 

 

20090 Vimodrone (MI) 
Italy 

 
Tel.:               
Fax Sales:    
E-mail:   
Web site:             

 
(+39) 02. 250.79.1 
(+39) 02. 250.79.767  

[email protected]

 

http://www.dropsa.com

 

 

 

 

DICHIARAZIONE 

 DI CONFORMITÁ/DECLARATION OF COMPLIANCE WITH STANDARDS/ 

DECLARATION DE CONFORMITE/

 

KONFORMITÄTSERKLÄRUNG DES STANDARDS /DECLARACIÓN DE CONFORMIDAD/

 

DECLARAÇÃO DE CONFORMIDADE 

 

La società Dropsa S.p.A., con sede legale in Milano, Via Besana,5/ Dropsa S.p.A., registered office in Milan, Via Besana,5 
/ Dropsa S.p.A. au Siège Social à Milan, Via Besana,5/ Dropsa S.p.A., Sitz in Milano, Via Besana 5/ La sociedad Dropsa 
S.p.a., con sede legal en Milán, Via Besana,5/ A Dropsa S.p.A, com sede em Milão, via Besana, nº 5 

 
 

DICHIARA /CERTIFIES / CERTIFIE/ ZERTIFIZIERT, DASS/ DECLARA/ CERTIFICA: 

 

che il prodotto denominato/that the product called/ le produit appelè/ das Produkt mit dem Namen/ el producto que se 
llama/ o produto chamado: 

“Mini-SUMO Atex

 ELECTRIC PUMP

” 

Code: Fam. 2487*** (all versions included) 

Category: II2GD 

Temperature Class: T5/T100 °C 

Gas Group: IIC + H2 

Year of construction: 20xx 
Technical File: 2012-01-00 

 

è conforme alle condizioni previste dalle Direttive CEE /has been constructed in conformity with the Directives Of The 
Council Of The European Community on the standardization of the legislations of member states/ a été construite en 
conformité avec les Directives Du Conseil Des Communautes Europeennes/ Entsprechend den Richtlinien des Rates Der 
Europäischen Union, für die Standarisierung der Legislative der Mitgliederstaaten, konstruiert wurde/ cumple con las 
condiciones establecidas por las directivas comunitarias/ foi construído em conformidade com as diretivas do Conselho 
das Comunidades Europeias: 
 

 

 

2006/95 CE

 

Bassa tensione / Low Voltage Directive / Directive Basse Tension/ Niedrigspannungsrichtlinien/ Directiva de 
baja tensión/ Directiva de Baixa Tensão; 

 

2004/108 CE  Compatibilità  elettromagnetica/  Electromagnetic  Compatibility/  Compatibilité  electromagnétique/ 

Elektromagnetische Verträglichkeit/ Compatibilidad electromagnetica / Compatibilidade Eletromagnética  

 

 

                                                                                                                  

           

                  

 

94/9 CE 

Direttiva Atex Atmosfere Esplosive/ ATEX Explosive Atmospheres Directive/ Directive ATEX  Atmosphères explosives/ATEX 
explosionsgefährdeten Bereichen Richtlinie 94-9-EG

 

/Atmósferas explosivas ATEX/Directiva ATEX Atmosferas Explosivas  

 

 

 

 

 

 

 

 
 

 
 
 
 
 
 
 
 
 

17. DECLARATION OF CONFORMITY 

 

 
 
 
 
 
 
 
 

Technical Director: 

Maurizio Greco 

 

..................................... 

 

Legal representative 

Milena Gavazzi 

 

..................................... 

 
 

M
i
l
e

       

 

 Vimodrone (MI), Aprile 2012    

 

La persona autorizzata a costituire il Fascicolo Tecnico presso Dropsa S.P.A.

 

    

The person authorized to compile the Technical File care of Dropsa S.P.A.

 

   

 

Содержание Mini-SUMO

Страница 1: ...http www dropsa com CONTENTS 1 INTRODUCTION 2 GENERAL DESCRIPTION 3 TECHNICAL CHARACTERISTICS 4 PUMP COMPONENTS AND TECHNICAL CONNECTIONS 5 UNPACKING AND INSTALLATION 6 INSTRUCTIONS FOR USE 7 PROBLEMS...

Страница 2: ...ication pump series is particularly suited for dual line systems and progressive systems and can be adapted to many needs without making mechanical changes even after installation is complete In fact...

Страница 3: ...es classified as 1 zone 2 zone included and 21 zone 22 zone included c Protection mode designed for the method of construction EN 13463 5 normative k Protection mode designed by oil immersion EN 13463...

Страница 4: ...hout reservoir 42 Kg ELECTRICAL CHARACTERISTICS Motor power supply 3 Ph 0 25 Kw 230 400Y 50 60 Hz Maximum working voltage 690V Motor degree of protection IP 65 Minimum and maximum level Capacitive las...

Страница 5: ...e 2 0 600 BAR 0 380 BAR 0 67 cc stroke Pmax 380 BAR 300 Electropneumatic switch G BSP Lubricant loading Grease version Lubricant loading Oil version 0 600 BAR 0 18 kw 4p 0 380 BAR Hydraulic diagram fo...

Страница 6: ...e of 380 bar The pumping elements are assembled onto the pump body without disconnecting the hydraulic line thanks to a threaded cartridge design facilitating assembly disassembling Figure a Version w...

Страница 7: ...H A FLOAT OIL The level is made with two floats at the ends of metal shaft Lower float acts as a minimum level by closing a contact when the low position is reached The Upper floats acts as a maximum...

Страница 8: ...below is underline the positioning of the bar of grounding For a complete vision refer to assembly design Mini SUMO Atex pump must be connected to a good earth safety system WARNING the distance of pa...

Страница 9: ...INSTALLATION Pump assembly operations are not required The pump is fixed on a metal pallet that permits safe handling with a transpallet or fork lift truck The pallet was designed to be installed in t...

Страница 10: ...es Check that the electric connection was carried out correctly Once the pump has started check that the direction of rotation of the electric motor is as indicated by the arrow on the motor s protect...

Страница 11: ...eters is shown below Figure 6 30 kg reservoir Pos Level Output signal set up Height X mm Grease quantity kg A Absolute maximum level OUT 2 Fno nsP2 200 22 C Minimum level fsP2 390 11 B Maximum level O...

Страница 12: ...ve been positioned according to the power supply voltage Fill the tank Attention if the tank emptied itself and the electric signal indicating that the minimum level was reached was not given check th...

Страница 13: ...olishing the machine the identification plate and all other documents must be destroyed 11 ORDER INFORMATION 11 1 VERSIONS MINI SUMO ATEX ATEX Pump Ordering PUMP CODE STANDARD VERSIONS Mini SUMO Atex...

Страница 14: ...7cc turn 0297010C Electric pneumatic change over 24V DC 0083470 Electric pneumatic change over 24V AC 0083471 Electric pneumatic change over 110V AC 0083472 Electric pneumatic change over 230V AC 0083...

Страница 15: ...12 DIMENSIONS 12 1 VERSION WITH RESERVOIR 10 Kg 30 Kg A 344 5 533 5 B 699 888 C 565 754...

Страница 16: ...16 12 2 VERSION WITHOUT RESERVOIR...

Страница 17: ...c current Do not carry out any work on the machine before disconnecting it from the electrical power supply and making sure that no one can reconnect it during the operation All the installed equipmen...

Страница 18: ...selected and supplied by the manufacturer 15 CLEANING It is necessary to remove periodically dust from pump avoiding the spread in the air For this operation refers to Safety Officer 16 TRAINING Perso...

Страница 19: ...f subject product to an authorized Dropsa Sales Service location we will then either repair or replace such product s at out option and if determined to be a warranted defect we will perform such nece...

Страница 20: ...e Council Of The European Community on the standardization of the legislations of member states a t construite en conformit avec les Directives Du Conseil Des Communautes Europeennes Entsprechend den...

Страница 21: ...dropsa com Dropsa do Brazil Ind E Com Ltda Rua Sobralia 175 Sao Paulo Brazil Tel 55 011 5631 0007 Fax 55 011 5631 9408 E mail salesbr dropsa com Dropsa USA Inc 6645 Burroughs Ave 48314 2132 Srerling...

Отзывы: