background image

9. MAINTENANCE PROCEDURE 

 

Position the machine in such a way that it can be checked easily.  

Wear the correct individual protection gear in order to avoid contact with the mineral oil. 

 

It is necessary to periodically check as follows: 

 

 

VERIFICATION 

WORK CYCLE/RUNNING TIME 

The state of lubrication 

1000/every 6 months 

The oil/grease level 

2000/once a year 

Cleanliness of the filling and intake filter (where fitted) 

500/every 6 months 

 

 

The machine does not require special equipment for any inspection and/or maintenance activity. It is however 

recommended that the equipment used be suitable and in good condition so as to avoid damage to people or parts of 

the machine. 

 

 

9.1 Assembly/Disassembly 

No pump assembly operations are envisaged. 

For  wall mounting ensure adequate space is available (as shown in the installation diagram) to avoid abnormal 

postures and possible impacts; four fixing holes are provided for wall mounting and three for base fitting. 

Subsequently it will be necessary, as previously described, to connect the pump to the machine hydraulically and then 

to connect the control panel. 

During the disassembly phase ensure the tank is empty. 

Disconnect the electrical and hydraulic parts. 

Where the machine is to be scrapped, do not dispose of potentially polluting parts in the environment, following local 

regulations for their correct disposal. 

At the time of the machine being scrapped it is necessary to remove and destroy the identification plate and all other 

relative documents. 

 

 

9.2 Regulation 

Flow rate (for versions with adjustable flow rates) 

It is possible to regulate the flow rate by rotating the regulating screw (8 mm hexagonal key) clockwise to decrease 

and anticlockwise to increase (remove the cap B).  

 

 

9.3  Repairs 

The following diagnostic table indicates the main anomalies which may be encountered, the probable causes  and 

possible solutions. 

The anomalies shown are: 

 

the pump fails to deliver lubricant 

 

irregular pressure 

 

irregular flow rate 

In case of doubts and/or problems which cannot be resolved do not attempt to disassemble parts of the machine but 

contact the Engineering Department of DROPSA S.p.A. 

 

Содержание 989 Series

Страница 1: ...TS 6 UNPACKING AND INSTALLING THE MACHINE 7 INSTRUCTIONS FOR USE 8 TROUBLESHOOTING 9 MAINTENANCE PROCEDURE 10 DISPOSAL 11 ORDERING INFORMATION 12 DIMENSIONS 13 HANDLING AND TRANSPORTATION 14 OPERATING...

Страница 2: ...on of use of this system or its parts without prior written authorization from DROPSA S p A will absolve the latter from any responsibility for injury or damage to persons and or property and will rel...

Страница 3: ...ory It is possible to adjust working pressure by means of a by pass valve installed on delivery line The use of the by pass valve it s recommended to control the pump operating and to avoid over press...

Страница 4: ...t of there being damage to the power supply cable or the unit DO NOT put the system into service Replace the damaged power supply cable with a new one The unit can be opened and repaired ONLY by quali...

Страница 5: ...art button of the machine to which the 989 series pump is connected 3 Verify the starting of the pump 4 Verify the adequate lubrication of the machine if doubt exists as to the correct functioning con...

Страница 6: ...es the bearing points in incorrect quantities The distributor is not correctly connected to the bearing points Verify that the dosages are those indicated in the system diagram Delivery is not correct...

Страница 7: ...t the power and the hydraulic supplies are off and there is no residual pressure in the main branch pipe Adjustable delivery pumping unit Part No 299041 6 mm Part No 299042 8 mm Fixed delivery pumping...

Страница 8: ...it will be necessary as previously described to connect the pump to the machine hydraulically and then to connect the control panel During the disassembly phase ensure the tank is empty Disconnect the...

Страница 9: ...e Electro pump 1 pumping unit 8 mm 24 V DC 989011 Grease Electro pump 1 pumping unit 6 mm 989012 Grease Electro pump 1 pumping unit 8 mm Part No Description 220 380 V 50 60 Hz 989003 Grease Electro pu...

Страница 10: ...precautions are required except as noted on the package itself Handling must be effected by at least two persons POS DIMENSIONS mm in A 539 5 21 24 B 334 13 15 C 71 2 79 D 220 8 66 E 120 4 72 FOR WAL...

Страница 11: ...ase it is possible to encounter squirts of oil for this reason appropriate protective clothing must be worn contact with oil see the requirements for the use of suitable personal protective clothing u...

Страница 12: ...paid receipt of subject product to an authorized Dropsa Sales Service location we will then either repair or replace such product s at out option and if determined to be a warranted defect we will per...

Страница 13: ...ed le produit appel das Produkt mit dem Namen el producto que se llama o produto chamado Descrizione Description Description Beschreibung Descripci n Descri o Pompa a pistoni Piston pump Nome Commerci...

Страница 14: ...k dropsa com Dropsa do Brazil Ind E Com Ltda Rua Sobralia 175 Sao Paulo Brazil Tel 55 011 5631 0007 Fax 55 011 5631 9408 E mail salesbr dropsa com Dropsa USA Inc 6645 Burroughs Ave 48314 2132 Srerling...

Отзывы: