background image

11 

 

14. OPERATING HAZARDS 

 

 

 

 

 

 

Power supply 

Any type of intervention must not be carried out  before unplugging the machine from power supply. Make sure that 

no one can start it up again during the intervention.  

All the installed electric and electronic equipment, reservoirs and basic components must be grounded. 

 

Flammability 

The lubricant generally used in lubrication systems is not normally flammable. However, it is advised to avoid contact 

with extremely hot substances or naked flames. 

   

Pressure 

Prior to any intervention, check the absence of residual pressure in any branch of the lubricant circuit as it may cause 

oil sprays when disassembling components or fittings. 

  

Noise  

Pump does not produce excessive noise, less than 70 dB(A) . 

 

 

15. PRECAUTIONS 

 

The verification of conformity with the essential safety requirements and regulations of the Machine Directive is 

effected by means of the compilation of a check list which has been pre-prepared and is contained in the 

technical file.

 

The lists which are utilised are of three types: 

 

list of dangers (as in EN 414 referring to EN 292) 

 

application of essential safety requirements (Machine Dir.) 

 

electrical safety requirements (EN 60204-1). 

 

The following is a list of dangers which have not been fully eliminated but which are considered acceptable: 

 

in the version of the pump without a release it is possible to encounter squirts of oil (for this reason 

appropriate protective clothing must be worn) 

 

contact with oil -> see the requirements for the use of suitable personal protective clothing 

 

use of unsuitable lubricant -> the characteristics of the fluid are shown on the pump and in the manual (in 

case of doubt contact the Eng. Dept of Dropsa Spa

 

protection against direct and indirect contact must be provided by the user 

 

given the purpose of the pump it must always be functioning; for this reason it is necessary to pay attention 

to the electrical connections which, in the case of a power failure, the customer’s machine is restarted only by 

means of a reset, while the lubrication pump is able to restart automatically. 

 

incorrect assembly of the regulator (valve) can result in an over pressure which can prejudice the functioning 

of the pump itself and create danger for the user. This is avoided by stamping the mounting instructions on 

the table. 

 

 

Fluid 

Danger 

Lubricants with abrasive additives 

High wear rate of contacted parts 

Lubricants with silicone based additives 

Seizure of the pump 

Petrol – solvents – inflammable liquids 

Fire – explosion – damage to seals 

Corrosive products 

Corrosion of the pump– injury to persons 

Water 

Oxidation of the pump 

Food substances 

Contamination of the substances themselves 

 

 

WARNING: It is necessary to carefully read about the instructions and the risks involved in the use 

of lubrication machines. The operator must know the machine functioning through the User and 

Maintenance Manual. 

 

Содержание 989 Series

Страница 1: ...TS 6 UNPACKING AND INSTALLING THE MACHINE 7 INSTRUCTIONS FOR USE 8 TROUBLESHOOTING 9 MAINTENANCE PROCEDURE 10 DISPOSAL 11 ORDERING INFORMATION 12 DIMENSIONS 13 HANDLING AND TRANSPORTATION 14 OPERATING...

Страница 2: ...on of use of this system or its parts without prior written authorization from DROPSA S p A will absolve the latter from any responsibility for injury or damage to persons and or property and will rel...

Страница 3: ...ory It is possible to adjust working pressure by means of a by pass valve installed on delivery line The use of the by pass valve it s recommended to control the pump operating and to avoid over press...

Страница 4: ...t of there being damage to the power supply cable or the unit DO NOT put the system into service Replace the damaged power supply cable with a new one The unit can be opened and repaired ONLY by quali...

Страница 5: ...art button of the machine to which the 989 series pump is connected 3 Verify the starting of the pump 4 Verify the adequate lubrication of the machine if doubt exists as to the correct functioning con...

Страница 6: ...es the bearing points in incorrect quantities The distributor is not correctly connected to the bearing points Verify that the dosages are those indicated in the system diagram Delivery is not correct...

Страница 7: ...t the power and the hydraulic supplies are off and there is no residual pressure in the main branch pipe Adjustable delivery pumping unit Part No 299041 6 mm Part No 299042 8 mm Fixed delivery pumping...

Страница 8: ...it will be necessary as previously described to connect the pump to the machine hydraulically and then to connect the control panel During the disassembly phase ensure the tank is empty Disconnect the...

Страница 9: ...e Electro pump 1 pumping unit 8 mm 24 V DC 989011 Grease Electro pump 1 pumping unit 6 mm 989012 Grease Electro pump 1 pumping unit 8 mm Part No Description 220 380 V 50 60 Hz 989003 Grease Electro pu...

Страница 10: ...precautions are required except as noted on the package itself Handling must be effected by at least two persons POS DIMENSIONS mm in A 539 5 21 24 B 334 13 15 C 71 2 79 D 220 8 66 E 120 4 72 FOR WAL...

Страница 11: ...ase it is possible to encounter squirts of oil for this reason appropriate protective clothing must be worn contact with oil see the requirements for the use of suitable personal protective clothing u...

Страница 12: ...paid receipt of subject product to an authorized Dropsa Sales Service location we will then either repair or replace such product s at out option and if determined to be a warranted defect we will per...

Страница 13: ...ed le produit appel das Produkt mit dem Namen el producto que se llama o produto chamado Descrizione Description Description Beschreibung Descripci n Descri o Pompa a pistoni Piston pump Nome Commerci...

Страница 14: ...k dropsa com Dropsa do Brazil Ind E Com Ltda Rua Sobralia 175 Sao Paulo Brazil Tel 55 011 5631 0007 Fax 55 011 5631 9408 E mail salesbr dropsa com Dropsa USA Inc 6645 Burroughs Ave 48314 2132 Srerling...

Отзывы: