11.

 

PROBLEMS AND SOLUTIONS 

A  diagnostics  table  is  illustrated  below,  where  the  main  faults,  probable  causes  and  possible  solutions  to  be  immediately 
activated are indicated (contact Dropsa). 
In  case  of  any  issues  and/or  problems  that  cannot  be  resolved,  contact  the  Dropsa  Engineering  Department  rather  than 
searching for the fault by disassembling components of the pump. 

TROUBLESHOOTING TABLE 

FAULT 

FAULT 

FAULT 

The pump motor does not work 

No current arrives. 

Check the electrical power supply system.

 

The  electronic  control  board  is  not 
working. 

Replace the electronic control board 

The motor does not work. 

Replace the motor

The pump works but lubrication 
does not arrive at the lubrication 
points. 

Lines disconnected.

 

Check  the  condition  of  the  lines  and  the  relative 
connections to the fittings. Replace worn lines.

 

Progressive distributor blocked 

Clean or replace the distributor  

The lubricant is distributed to the 
lubrication points in irregular 
doses. 

The distributor is not connected 
correctly to the lubrication points. 

Check the dosages against the system diagram.

 

Incorrect setting of the pause time. 

Re-programme the pause time. 

The display is off. 

The supply voltage is not correct. 

Check  that  the  supply  voltage  is  indicated  on 
the identification plate. 

Touch  screen  does  not  respond 
correctly 

Non-calibrated touch screen 

To re-calibrate the touch-screen, you must: 

• Turn off the pump 
• Press the touch-screen 
• Turn the pump back on 
•  3  seconds  after  switching  on  the  display, 
release the touch-screen 

Perform the operations shown on the display 

The pump begins the greasing 
phase but ends it immediately. 

Defective motor or high output 
absorption. 

Allow to cool for a few minutes and try again. If 

the problem persists, replace the motor 

The  pump  does  not  dispense 
lubricant.

 

The reservoir is empty. 

Fill the reservoir with clean lubricant. 

The cartridge is empty. 

Replace  the  cartridge and if necessary remove as 
indicated for the 1

st

 filling. 

Air bubbles in the lubricant. 

Disconnect the primary line from the pump 
connection fitting. Activate the pump according to 
the manual operating cycle until lubricant comes 
out of the fitting without any air bubbles. 

Use of unsuitable lubricant. 

Empty the tank and refill it with suitable lubricant. 

Pumping suction clogged. 

Disassemble the pumping unit and clean the 
suction inlets. 

The pumping unit piston is worn. 

Replace the pumping unit. 

The pumping unit lubricant pump 
outlet is blocked. 

Replace the pumping unit. 

 

 

Operations that can be carried out only be specialized Dropsa personnel. 

12.

 

MAINTENANCE PROCEDURES 

The pump does not  require special tools for any check  and/or maintenance operations. In any case, we recommend using 
tools  and  personal  protective  equipment  suitable  for  the  use  (gloves,  eye  protection,  etc.)  and  in  good  condition  in 
accordance with prevailing regulations in order to prevent damage to people or parts of the pump. 
The unit was designed and built in a way to require minimum maintenance operations. In any case, we recommend always 
keeping the body of the equipment clean and periodically checking the line joints in order to promptly detect any leaks. 
 

 

ATTENTION: Before any maintenance or cleaning operation, ensure that the hydraulic and electrical supplies 

are disconnected. 

 

 
 
 

Содержание 888580

Страница 1: ...INGS OF LUBRICATION CONTROL 10 APPLICATION EXAMPLES 11 PROBLEMS AND SOLUTIONS 12 MAINTENANCE PROCEDURES 13 DISPOSAL 14 ORDERING INFORMATION 15 DIMENSIONS 16 HANDLING AND TRANSPORT 17 PRECAUTIONS FOR U...

Страница 2: ...variables such as the volume and frequency of the grease required for each point the number of points the management conditions and the pressure of the pump 2 2 DIRECT LUBRICATION TO THE POINT MULTI L...

Страница 3: ...L TECHNICAL CHARACTERISTICS Pumping system Type Cam with spring return Flow rate Multi line cm 3 rev in 3 rev 0 005 0 01 0 015 0 025 0 05 0 0003 0 0006 0 0009 0 0015 0 003 Progressive cm 3 min in 3 mi...

Страница 4: ...flow rate value refers to the following test conditions grease with NLGI 2 consistency class standard environmental conditions Temperature 20 C 68 F pressure 1bar 14 5psi counter pressure of 50bar 73...

Страница 5: ...H CARTRIDGE 700CC 400CC 5 3 PROGRESSIVE PUMPING UNIT FIXED FLOW RATE ADJUSTABLE FLOW RATE Magnet for minimum level Preloaded cartridge Cartridge guard Minimum level with reed Notches M22x1 5 Output G1...

Страница 6: ...INE PUMPING UNIT 5 5 KIT BY PASS OPTIONAL WITHOUT pressure gauge WITH pressure gauge 5 6 KIT VENT VALVE OPTIONAL Solenoid valve DIN 43650 Connection to the pumping unit Pos B Progressive G1 4 Discharg...

Страница 7: ...tures Do not install the pump near heat sources or electrical equipment that may disrupt correct operation of the electronics Ensure that pipes and cables are appropriately secured and protected from...

Страница 8: ...DC Ground 4 Black Input 1 4 Black Output 1 max 1A 5 Green Ground Input signals Omega connector System sensors Pin Description Connection NPN PNP CONTATTO 1 3 2 Input 2 4 Input 1 Input signals Omega co...

Страница 9: ...g is free of any air bubbles Check for proper connection of the electrical devices To determine the maximum operating pressure you must know the pressure drop for the piping connected to the pumping u...

Страница 10: ...10 EMPTY LOADING MAXIMUM LEVEL with air MAXIMUM LEVEL without air OVER MAXIMUM LEVEL SAFETY DISCHARGE Max liv 10mm Grease outlet Air venting Min liv Air Grease...

Страница 11: ...ensuring that you evacuate all the air in the mouth Taking care not to allow the air to come back in screw the cartridge onto the pump all the way tightening it moderately Insert the magnet in the ne...

Страница 12: ...remains on hold before the start of the next lubrication cycle or the standby phase if only one lubrication cycle is set The lube can be adjusted in five ways PS SEP Discharging of lubricant is contr...

Страница 13: ...u can view additional information concerning the status of the alarm warning present BASE MENU Allows you to enter the base programming menu STATUS BAR Displays active Alarms Warnings current date and...

Страница 14: ...the entire system 3 LUBRICANT From the Lubricant menu it is possible to activate deactivate notifications corresponding to filling and or reorganization of the lubricant contained in the pump 4 SYSTEM...

Страница 15: ...the interface navigation between the settings menus and it contains a detailed explanation of every parameter and the possible values that they can assume The pump can be managed with 2 MAIN MENU BASI...

Страница 16: ...nd consequently the pump does not start the lubrication cycle To resolve this error you need to change the parameter s with a correct combination of parameters 9 1 1 1 PARAMETERS RELATING TO THE OPERA...

Страница 17: ...ted Pulse Count Pulse Count Suspensions 6 Pulse count Not Connected Pulse Count Pulse Count Suspensions 7 Time Pulses Not Connected Pulse Count Pulse Count Suspensions 8 Pulses Timeout Not Connected P...

Страница 18: ...TERS RELATING TO LUBRICATION SETTING The following table shows the operating parameters present only in the ADVANCED MENU relating to lubrication and the possible values that can be set The Operating...

Страница 19: ...ixed e Pause lamp Conduct of lubrication status output Only lubrication Lub fixed and Pause lamp Lub status output Lubrication output status contact Type P Lubrication Status Output signal type Type N...

Страница 20: ...oot Device Device reboot button Time zone Time zone 2H 00M Time zone setting 12H 00M 12H 00M Device Info Device Info Pump general information display button Current date Current date Setting of curren...

Страница 21: ...SEP a typical application can be implemented using operating mode 2 PS SEP Pulses with the following settings Basic parameters o Interval Pulses 2 Advanced Parameters o Input 1 Pulses Count o Input 2...

Страница 22: ...00s Advanced Parameters o Input 1 Pulses Count o Input 2 Not connected o Number of cycles 1 With this configuration the lubrication phase is formed of a single cycle Number of cycles 1 that starts ev...

Страница 23: ...ations shown on the display The pump begins the greasing phase but ends it immediately Defective motor or high output absorption Allow to cool for a few minutes and try again If the problem persists r...

Страница 24: ...hours Every 1500 hours Check the fitting connection Check fixing to the parts of the machine Tank level As required Restore the lubricant level in the tank Filling filter As required Check and replace...

Страница 25: ...133645 Laser probe tank kit 0039976 Power supply connector 3133646 Venting valve kit 24VDC 0039830 4 pin signals connector 0039976 DIN 43650 connector without cable 0888520 700cc cartridge guard 00390...

Страница 26: ...26 15 DIMENSIONS Version 700cc Cartridge Version 400cc Cartridge Version 400cc Cartridge Dimensions in mm in...

Страница 27: ...tive 93 112 EEC related to the type of lubricant selected and supplied by the manufacturer NOTE The pump is designed to work with maximum NLGI 2 grade lubricants Use NBR gasket compatible lubricants A...

Отзывы: