5
5. TECHNICAL CHARACTERISTICS
CHARACTERISTICS
Electrical power supply:
24, 110, 220, Vac 50 – 60 Hz Single phase
Absorbed power
Max 2.5 W
Working temperature
- 15
÷
+ 60
°
C
Operating humidity
90 % rel. humidity
Grade of mechanical protection
IP 54
Lubricants
32
÷
250 cSt Mineral oil lubrucat
Preservation temperature
-30
÷
+90 °C
Level of continuous sound pressure
< 70 dB(A)
ATTENTION:
do not use the machine with different voltage that shown on the nameplate.
6.
HANDLING AND TRANSPORTATION
Prior to shipping, the equipment is carefully packed in cardboard package. During transportation and storage, always
maintain the pump the right way up as indicated on the box. On receipt check that package has not been damaged. Then,
store the machine in a dry location.
7.
PRECAUTIONS
It is necessary to carefully read the warnings and risks associated with using a lubricant pump. The operator must
understand how it works and must clearly understand the dangers by studying the user manual.
Power supply
Any type of intervention must not be carried out before unplugging the machine from power supply. Make sure that no
one can start it up again during the intervention.
All the installed electric and electronic equipment, reservoirs and basic components must be grounded.
Flammability
The lubricant generally used in lubrication systems is not flammable. However, it is advised to avoid contact with
extremely hot substances or naked flames.
Pressure
Prior to any intervention, check the absence of residual pressure in any branch of the lubricant circuit as it may cause oil
sprays when disassembling components or fittings.
Noise
Pump produces noise, not more than 70 dB(A).