4.8 DANGERS PRESENT IN USE
The verification of conformity with the essential safety requirements and regulations of the Machine Directive is effected by
means of the compilation of a check list which has been pre-prepared and is contained in the technical file.
The lists which are utilised are of three types:
•
List of dangers (as in EN 414 referring to EN 292)
•
Application of essential safety requirements (Machine Dir. 06/42)
•
Electrical safety requirements (EN 60204-1)
The following is a list of dangers which have not been fully eliminated but which are considered acceptable:
•
In the version of the pump without a release it is possible to encounter squirts of oil (for this reason appropriate protective
clothing must be worn)
•
Contact with oil -> see the requirements for the use of suitable personal protective clothing
•
Use of unsuitable lubricant -> the characteristics of the fluid are shown on the pump and in the manual (
in case of doubt
contact the Eng. Dept of Dropsa Spa
)
•
Protection against direct and indirect contact must be provided by the user
•
Given the purpose of the pump it must always be functioning; for this reason it is necessary to pay attention to the electrical
connections which, in the case of a power failure, the customer’s machine is restarted only by means of a reset, while the
lubrication pump is able to restart
INADMISSIBLE FLUIDS
Fluids
Danger
Lubricants with abrasive additives
High wear rate of contacted parts
Lubricants with silicone based additives
Seizure of the pump
Petrol – solvents – inflammable liquids
Fire – explosion – damage to seals
Corrosive products
Corrosion of the pump– injury to persons
Water
Oxidation of the pump
Food substances
Contamination of the substances themselves