background image

 

14/ 22 

7.4.5 Procedure for calibrating the ultrasound probe model ZWS-70/CI/QS (code 3289173)

 

 

Before being assembled the probe must be calibrated in accordance with the following sequence: 

 

1.

 

electrically connect the sensor (following the electric diagram shown below); 

2.

 

keep the sensor button pressed down until the two LED (green and yellow lights) flash together; 

3.

 

position  it  in  front  of  the  minimum  absolute  level  to  be  read,  entering  the  height  by  releasing  the  button  (the  two  LEDs 
display a fixed light); 

4.

 

press the button for 3 or 4 seconds (the probe has acquired the Minimum absolute level); 

5.

 

keep the sensor button pressed down until the two LED (green and yellow lights) flash together; 

6.

 

position it in front of the maximum absolute level to be read, entering the height by releasing the button (the two LEDs have 
a fixed light); 

7.

 

 press the button for 3 or 4 seconds (the probe has acquired the Maximum absolute level); 

8.

 

In this way the sensor is calibrated. 

 

N.B.:

 green Led on indicates that the probe is supplied. Yellow Led on indicates operating mode for reading. 

We attach a table with the calibration parameters for the ultrasound probe, for 30 and 100 kg tanks. 

 

Image 8 

 

 

 

 

Calibration of ultrasound probe 

Pos. 

 

 

30 kg tank 

100 kg tank 

 

Level 

Output 

signal 

height X 

[mm] 

Quantity of 

grease [kg] 

height X 

[mm] 

Quantity of 

grease [kg] 

Maximum 

absolute 

level 

Threshold

110 

25 

110 

92 

Minimum 

absolute 

level 

threshold 

490 

930 

 
 
 
 
 

Photo 9 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Image 9 

 
 
 
 
 
 
 
 
 

N.B.

: In the 

30 kg pump tank at the minimum absolute level  there is still a reserve of 7 kg

In the 100 kg pump tank at the minimum absolute level there is still a reserve of 15 kg.

 

 

 

 

Green LED:

 status indicator. 

Signals that the sensor is powered. 

 
Yellow LED: 

function indicator. 

Report the output status (On/Off).

 

Содержание 2477000

Страница 1: ...TICS 5 COMPONENTS 6 UNPACKING AND INSTALLING 7 OPERATING INSTRUCTIONS 8 TROUBLESHOOTING 9 MAINTENANCE PROCEDURES 10 DISPOSAL 11 ORDERING INFORMATION 12 DIMENSIONS 13 HANDLING AND TRANSPORTATION 14 PRE...

Страница 2: ...ction from a set of components which are fully compatible and easy to assemble the pressure quantity of lubricant delivered actual type of lubricant or type of distribution can be altered This constru...

Страница 3: ...ounted 30 Kg metal reservoir the system is complete with electrical control equipment that allows the pump motor control when the pressure exceed provided or in case of malfunction of the lubrificant...

Страница 4: ...80 Kg with transparent reservoir made of polyethylene for special applications E A B C D E F 780 734 630 580 1410 335 A B C D E F PLASTIC GREASE RESERVOIR 148 5 14 DISTANCE BETWEEN HOLES WITHOUT PALLE...

Страница 5: ...I 2 Max Degree of protection IP 55 Electric motor Three phase Power 0 75kW Protection IP55 class B Voltage 230 400 Volt 5 50 Hz 280 480Volt 5 60 Hz S1 continuous service N B do not supply the machine...

Страница 6: ...Manifold group Refilling oil cap with filter 10 m Min max float level indicator Electropneumatic switch P N 0083450 Connection 1 2 BSP Connection 3 8 BSP Line 1 Line 2 SINGLE OUTLET GREASE PUMP option...

Страница 7: ...of special high resistance steel which gives the pump better reliability and durability 5 3 INVERTORS CODE DESCRIPTION Series 0083420 Interchangeable electromagnetic inverter mounted as standard on S...

Страница 8: ...s manufactured to sustain high pressures via a pressure chamber optimising the inverter operations two control electromagnets equipped with a thermal probe with an intervention temperature of 100 C pr...

Страница 9: ...D MAXIMUM OIL LEVE Standard oil pumps have two types of level Minimum and maximum level float Maximum visual level float 5 6 1 Minimum and maximum level float A probe rod with dual float mounted on th...

Страница 10: ...se by the supplier to fix the pump correctly check the pitch dimensions shown in the figures in chapter 12 Use safety gloves and goggles as indicated in the safety sheet for the lubrication oil Do NOT...

Страница 11: ...On the pump is placed a label that shows the wiring diagram and setting values The pump is normally equipped with pre setting sensor to L thresholds minimum level Whereas other thresholds MM absolute...

Страница 12: ...or in digital mode two outputs and four intervention thresholds We attach a table showing the calibration parameters for the laser probe for 30 and 100 kg tank Image 6 LASER PROBE CALIBRATION 30 kg t...

Страница 13: ...for Laser probe 1 Press the MODE ENTER key once OU2 appears on the Display 2 Keep the SET button pressed down for 5 sec 3 When the wording on the Display no longer flashes press SET 4 times until Fno...

Страница 14: ...ght by releasing the button the two LEDs have a fixed light 7 press the button for 3 or 4 seconds the probe has acquired the Maximum absolute level 8 In this way the sensor is calibrated N B green Led...

Страница 15: ...ing to factory settings START Remove power END Release the button Press and hold the button while power is applied both LED flashing simultaneously Press the button for about 13 sec while the green LE...

Страница 16: ...ill the tank N B If the tank was emptied without the electric signal for reaching the minimum level being given the minimum level contact must be checked Remove the cover from the tank and check that...

Страница 17: ...incorrect Incorrect adjustment of the control pressure gauge The pressure value set is too high and the pressure adjustment valve bypass intervenes before the pressure gauge can be activated Incorrect...

Страница 18: ...rease version with LASER level 24V cc Out NO e NC 1 threshold 0295131 for 30 100 kg 0 STANDARD oil version with floating Reed 0295150 for 30 kg 0295160 for 100 kg Variants Min max laser level kit 24V...

Страница 19: ...I per non fare confusione con il numero 1 1 2 SPECIAL VERSIONS Equipment Description Code 400 cm 3 min grease pump 80Kg 176 lb transparent tank with inverter code 0083420 at 24 V DC 2477100 SUMO ATEX...

Страница 20: ...Kit 30 kg VAR 5 0295140 Ultrasound level Kit 100 kg VAR 6 Maximum and minimum float level kit 30 kg oil 0295150 Maximum and minimum float level kit 100 kg oil 0295160 Grease loading filter 0295009 By...

Страница 21: ...s indicated by at least 200 mm 7 87 in Image 13 Dimensions mm inches A 940 37 30 kg reservoir 1390 54 7 100 kg reservoir 1450 57 80 kg reservoir B 615 24 21 30 100 kg reservoir C 450 17 71 30 100 kg r...

Страница 22: ...N 292 Application of the essential safety requirements Machine Dir 06 42 electrical safety stipulations EN 60204 1 See below a list of dangers which have not been completely eliminated but are conside...

Отзывы: