6. UNPACKING AND INSTALLING
No pump assembly operations are envisaged. The pump is fixed on a metal pallet, which allows safe handling using a transpallet
or forklift truck. This pallet has been designed so that it can be installed in the installation, being equipped with 4 (four) holes of
Ø 14 mm suitable for fixing to the floor. Provide adequate space (as shown on the installation diagram) to avoid abnormal
posture or possible impact. Then, as described previously, the pump must be connected hydraulically to the machine and then
connected to the control panel.
7. OPERATING INSTRUCTIONS
7.1 GOING INTO OPERATION
Damage to the supply cable and housing may involve contact with live parts at high voltage and consequently fatal danger:
Check the integrity of the supply cable and the unit prior to use;
If the supply cable or the unit is damaged, do not start up the system!
Replace the damaged supply cable with a new one;
The unit can be opened and repaired only by specialist personnel;
In order to prevent the danger of electrocution due to direct or indirect contact with live parts, the electric power supply
line must be suitably protected by a specific differential magnetothermic switch, according to regulations and with rated
breaking capacity at list equal to prospective fault current at installation point.
The pump must not be used when submerged in fluids or in a particularly aggressive or explosive/inflammable atmosphere
unless prepared in advance for this purpose by the supplier;
to fix the pump correctly check the pitch dimensions shown in the figures in chapter 12;
Use safety gloves and goggles as indicated in the safety sheet for the lubrication oil;
Do NOT use lubricants which are aggressive towards NBR gaskets, and if in doubt consult the Dropsa SpA technical office
which will supply a detailed list of the recommended oils;
Do not ignore dangers to health and comply with health and safety regulations;
Warning! All the electric components must be earthed. This applies to both the electric components, and to the control
devices. To this end make sure that the earth wire is connected correctly. For safety reasons the earth conductor must be
approximately 100 mm longer than the phase conductors. If the cable is accidentally removed, the earth terminal must be
the last one to be removed.
7.2 ACTION TO BE TAKEN BEFORE START-UP
Check the integrity of the pump.
Refill the tank with suitable lubricant.
Check that the pump is at working temperature and that there are no air bubbles in the pipes.
Check that the electric connection has been carried out correctly.
7.3 USE
WARNING:
The unit is only to be opened and repaired by specialist personnel.
TYPE OF PROBE
TYPE OF INVERTER
VOLTAGE
V
CODE ELECTRICAL
APPARATUS VIP5 PRO
CODE ELECTRICAL
APPARATUS VIP5 PLUS
CODE ELECTRICAL
APPARATUS WITH PLC
LASER PROBE
(24V cc standard)
Out NO e NC
(1 threshold )
Electromagnetic
24 VDC
1639211
1639210
1637008
110 VAC
*
*
1637009
220 VAC
*
*
1637010
Electro pneumatic
24 VDC
1639211
1639210
1637011
110 VAC
*
*
1637012
220 VAC
*
*
1637013
LASER PROBE
24V cc Out 4÷20mA/2 NO
(4 thresholds )
Electromagnetic
24 VDC
1639211
1639210
1637001
110 VAC
*
*
1637003
220 VAC
*
*
1637004
Electro pneumatic
24 VDC
1639211
1639210
1637005
110 VAC
*
*
1637006
220 VAC
*
*
1637007