13
Fill water 1" above
gridplate.
System Setup
Add water to brine tank
approximately 1” above the
grid plate. Do not add salt
to the brine tank at this
time.
1/2” Overflow
Connection
INSTALLATION INSTRUCTIONS
Pass the salt sensor power
cord through the provided
hole from the inside of the
brine tank. Install the salt
sensor unit onto the top
of the brine well. Install the
cord grip around the salt
sensor power cord and
insert it into the hole in the
brine tank. Install the
supplied rubber band onto
the hooks on top of the salt
sensor unit.
Attach safety overflow line
(1/2” tubing) to barbed
fitting on side of brine
tank and run to appropriate
discharge point that is
lower than the overflow
connection on the brine
tank. Do not tee into any
other drains.
Power
Cord
Rubber
Band
Fill water 1”
above grid plate