Heatmax Furnace Installation and Operation Manual
6
INTRODUCTION
Take note that this furnace uses the same wood burning technology as a high efficiency
EPA certified wood burning furnace. This applies to the lighting, the ember bed, and the
minimum combustion air intake which was calibrated to burn good seasoned cordwood.
This model line is certified as meeting the emissions limits in 40 C.F.R. part 60, section
60.532 (B) per EPA methods 28 and 5G-3, February 1991.
Emissions: 6.6 g/h or 0.229 g/MJ
Average efficiency: 76 % (LHV) / 71% (HHV)
To optimize the efficiency of your furnace, here is some advice that you should follow
when installing or operating your Heatmax furnace:
•
Respect the local codes (when in doubt, consult your local dealer);
•
Check the specifications on the certification label about the clearances. Make sure that
they correspond to those included in the instruction manual.
•
Make sure your furnace is installed according to the instructions on the certification
label;
•
The furnace is fully assembled at the factory and no electrical connection is required
other than plugging the power cord into an outlet. It does not include automatic variable
speed control of the blower. Factory connection is on speed 2 (medium-low) but can be
modified. The blower speed must conform to the recommendations of the Warm Air
Heating and Air Conditioning National Association and should respect the static
pressure ranges in the warm air plenum of the furnace (see section 2.1.2, General
technical data.
•
We recommend that our woodburning hearth products be installed and serviced by
professionals who are certified in the United States by NFI (National Fireplace
Institute
®
) or in Canada by WETT (Wood Energy Technical Training) or in Quebec by
APC (Association des Professionnels du Chauffage).
Содержание DF01000
Страница 10: ...Heatmax Furnace Installation and Operation Manual 10 2 1 1 Technical data Heatmax...
Страница 38: ...Heatmax Furnace Installation and Operation Manual 38...
Страница 55: ...Heatmax Furnace Installation and Operation Manual 55...
Страница 65: ...Heatmax Furnace Installation and Operation Manual 65 Appendix 6 Exploded diagram and parts list...