Heatmax Furnace Installation and Operation Manual
41
7.5 Hot air distribution system
Your Drolet furnace is designed to receive a maximum of two eight inches diameter hot
air ducts that are located on the top of the cabinet. In the combustion chamber, you will
find the necessary adapters to start the air duct system.
2 hot air start-off adapter (A)
2 block-off plate (B)
8 block-off plate screws (C)
The total run of the hot air ducts should not exceed 50 feet. To avoid overheating and
assure a good hot air distribution, we recommend that the static pressure be set at 0,2’’ of
W.C.. Depending on the duct configuration, the setting of the blower speed (factory set at
medium low) can be changed to obtain to proper static pressure. Simply change the
location of the wire on the terminal.
You can choose from 2 duct outlet configuration. For optimum efficiency and to provide
even heat distribution, we recommend the outlet configuration “A”.